1 AWG 3C Unshielded Tray Cable W/ Ground XLPE Insulation PVC Jacket 600V E2
Applications:
Tray XHHW Cable is designed for use for power distribution channels when voltage does not exceed 600 volts. It is a type of instrumentation cable which is insulated and jacketed for maximum chemical and mechanical protection. This cable has a long service life and can withstand harsh outdoor environmental conditions. The cable is printed with numbers and color-coded for easy identification.
This cable is used in raceway systems, cable trays, free air, and direct burial in:
- • Burglar alarms
- • Cash registers
- • Control systems
- • Intercom wiring
- • Petrochemical facilities
- • Industrial control systems
The electrical cable is also suitable for NEC Class 1 Division 2 hazardous locations. XHHW tray cable is equally effective as a power and control cable. The electrical cable is flame-retardant. s and sunlight-resistant, s a recommended maximum temperature of 90°C. The minimum recommended temperature is -25°C. The electrical cable also has excellent moisture resistance.
Also Known As:
1 AWG 3C Cable Tray, 1 AWG 3C Cable Tray Types, 1 AWG 3C Electrical Cable Tray, 1 AWG 3C Pvc Cable Tray, 1 AWG 3C wire cable tray, 1 AWG 3C cable tray wire, 1 AWG 3C Tray Instrument Cable, 1 AWG 3C Tray Instrumentation Cable, 1 AWG 3C TC-ER Cable, 1 AWG 3C direct burial tray cable, 1 AWG 3C XLP Cable, 1 AWG 3C PVC Cable, 1 AWG 3C Exposed Run Tray Cable, 1 AWG 3C XHHW tray cable, 1 AWG 3C XHHW tray wire, 1 AWG 3C tinned copper tray cable, 1 AWG 3C flame-retardant tray cable, 1 AWG 3C tray power cable, 1 AWG 3C ray control cable.
Standards:
• UL Listed as TC-ER (Exposed Run) per UL Standard 1277 and used in accordance with NEC for 3 or more conductors.
• Approved for Class 1 or 2, Division 2 industrial hazardous locations per NEC
• Individual conductors pass UL VW-1 flame test and rated XHHW-2/VW1, UL 1581/UL 2556 VW-1
• Rated at 90°C wet or dry
• Oil Res I & II
• “Heavy Duty” rating per ICEA Standards
• Meets cold bend test at -25°C
• NEMA WC70/ICEA S-95-658, NEMA WC57/ICEA S-73-532
• IEEE 1202 and CSA FT4 70,000 BTU Flame Test
• IEEE 383 70,000 BTU Vertical Flame Test
• ICEA T-29-520 210,000 BTU
Conductor:
• Fully annealed bare copper per ASTM B-3, Class B stranding per ASTM B-8
Insulation:
• Flame retardant Cross-linked Polyethylene (FR-XLPE) that is heat and moisture resistant. Also has a VW-1 rating and is XHHW-2 per UL 44
Ground:
• Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8
Assembly:
• Conductors are cabled together with or without fillers as required to form a round compact cable core with a binder tape
Jacket:
• Flame and sunlight resistant black PVC rated 90°C wet or dry per UL 1277
Options:
• ICEA Method 1, Table E-1 Color Code
Specification:
• Gauge: 1 AWG
• No. Conductors: 3
• No. of Strands: 19
• Ground Wire Size : 6 AWG
• Insulation Thickness: 0.055 Inches
• Jacket Thickness: 0.080 Inches
• Overall Diameter : 1.093 Inches
• New Weight lb/1000FT: 1200 Lbs
Manufacturer Equivalents |
|
Omni Cable : | A60103 |
Priority Wire : | 1-03TCG-XLP |