1 AWG 3C Unshielded Tray Cable W/ Ground XLPE Insulation PVC Jacket 60
nassaunationalcable.com/es/products/1-awg-3c-unshielded-tray-cable-w-ground-xlpe-insulation-pvc-jacket-600v-e2

Items in Cart ()

View cart

1 AWG 3C Unshielded Tray Cable W/ Ground XLPE Insulation PVC Jacket 600V E2

1 AWG 3C Unshielded Tray Cable W/ Ground XLPE Insulation PVC Jacket 600V E2
Roll over image to Zoom

1 AWG 3C Unshielded Tray Cable W/ Ground XLPE Insulation PVC Jacket 600V E2

SKU: NNC32218X
tray-cables

Select a Gauge

1 AWG 3C Unshielded Tray Cable W/ Ground XLPE Insulation PVC Jacket 600V E2

Availability: In stock

Min Length: 1 FT
Max Length: 10000 FT
Price:
Precio habitual
$16.28
Precio de oferta
$10.28 /FT 36% off
Los gastos de envío se calculan en la pantalla de pagos.
Free Shipping: On orders above $1000
La cantidad debe ser 1 o más

Enter the required footage in the quantity box - Cut to one length

Where are we? 4 Continents 8 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Chat

Live Chat: Bottom Right Corner!

Email Us

info@nassaunationalcable.com

Product Information

Specification

1 AWG 3C Unshielded Tray Cable W/ Ground XLPE Insulation PVC Jacket 600V E2

Applications:

Tray XHHW Cable is designed for use for power distribution channels when voltage does not exceed 600 volts. It is a type of instrumentation cable which is insulated and jacketed for maximum chemical and mechanical protection. This cable has a long service life and can withstand harsh outdoor environmental conditions. The cable is printed with numbers and color-coded for easy identification.

This cable is used in raceway systems, cable trays, free air, and direct burial in:

  • • Burglar alarms
  • • Cash registers
  • • Control systems
  • • Intercom wiring
  • • Petrochemical facilities
  • • Industrial control systems

The electrical cable is also suitable for NEC Class 1 Division 2 hazardous locations. XHHW tray cable is equally effective as a power and control cable. The electrical cable is flame-retardant. s and sunlight-resistant, s a recommended maximum temperature of 90°C. The minimum recommended temperature is -25°C. The electrical cable also has excellent moisture resistance.

Also Known As:

1 AWG 3C Cable Tray, 1 AWG 3C Cable Tray Types, 1 AWG 3C Electrical Cable Tray, 1 AWG 3C Pvc Cable Tray, 1 AWG 3C wire cable tray, 1 AWG 3C cable tray wire, 1 AWG 3C Tray Instrument Cable, 1 AWG 3C Tray Instrumentation Cable, 1 AWG 3C  TC-ER Cable, 1 AWG 3C  direct burial tray cable, 1 AWG 3C XLP Cable, 1 AWG 3C PVC Cable, 1 AWG 3C Exposed Run Tray Cable, 1 AWG 3C XHHW tray cable, 1 AWG 3C XHHW tray wire, 1 AWG 3C tinned copper tray cable, 1 AWG 3C flame-retardant tray cable, 1 AWG 3C tray power cable, 1 AWG 3C  ray control cable.

 

Standards:

• UL Listed as TC-ER (Exposed Run) per UL Standard 1277 and used in accordance with NEC for 3 or more conductors.
• Approved for Class 1 or 2, Division 2 industrial hazardous locations per NEC
• Individual conductors pass UL VW-1 flame test and rated XHHW-2/VW1, UL 1581/UL 2556 VW-1
• Rated at 90°C wet or dry
• Oil Res I & II
• “Heavy Duty” rating per ICEA Standards
• Meets cold bend test at -25°C
• NEMA WC70/ICEA S-95-658, NEMA WC57/ICEA S-73-532
• IEEE 1202 and CSA FT4 70,000 BTU Flame Test
• IEEE 383 70,000 BTU Vertical Flame Test
• ICEA T-29-520 210,000 BTU

Conductor:

• Fully annealed bare copper per ASTM B-3, Class B stranding per ASTM B-8

Insulation:

• Flame retardant Cross-linked Polyethylene (FR-XLPE) that is heat and moisture resistant. Also has a VW-1 rating and is XHHW-2 per UL 44

Ground:

• Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8

Assembly:

• Conductors are cabled together with or without fillers as required to form a round compact cable core with a binder tape

Jacket:

• Flame and sunlight resistant black PVC rated 90°C wet or dry per UL 1277

Options:

• ICEA Method 1, Table E-1 Color Code

Specification:

• Gauge: 1 AWG
• No. Conductors:
 3
• No. of Strands:
 19
 Ground Wire Size : 6 AWG
• Insulation Thickness:
0.055 Inches
• Jacket Thickness:
 0.080 Inches
• Overall Diameter :
1.093 Inches
• New Weight lb/1000FT:
1200 Lbs

Manufacturer Equivalents

Omni Cable : A60103
Priority Wire : 1-03TCG-XLP


*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color

Reviews

Get in Touch
Live Chat Get replies right away!
Email info@nassaunationalcable.com

Call Us: 1-516-482-6313    Text Us: 1-516-703-3460