1/0-1/0-2 ALUMINUM SEU CABLE

Where are we? 4 Continents 8 Countries


Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
1/0-1/0-2 ALUMINUM SEU CABLE
Allowable Ampacity for 1/0-1/0-2 ALUMINUM SEU CABLE at 60°C: 100 Amps
Allowable Ampacity for 1/0-1/0-2 ALUMINUM SEU CABLE at 75°C: 120 Amps
Allowable Ampacity for 1/0-1/0-2 ALUMINUM SEU CABLE at 90°C: 135 Amps
Applications:
1/0-1/0-2 Aluminum SEU cable is primarily used as a service entrance cable in residential applications, supplying 120/240V power from the utility meter to the main breaker panel. It is rated for 600V and designed for dry locations, with an operating temperature up to 90°C.
This 1/0-1/0-2 size, with an ampacity of 125 Amps in dwelling applications, is commonly used for:
- Main service panel feeds in medium-sized residential homes.
- Meter-to-panel connections in single-family dwellings and small multi-unit buildings.
- 125 Amp service upgrades or replacements.
Also Known As:
1/0-1/0-2 aluminum seu cable, 1/0-1/0-2 seu service entrance cable, 1/0-1/0-2 seu cable, 1/0-1/0-2 seu wire, 1/0-1/0-2 600v wire, 1/0-1/0-2 600v cable, aluminum cable
Standards:
-
Ampacities based on National Electric Code, 2005 edition, section 310-15
-
60°C when terminated to equipment for circuits rated 100 Amps or less or marked for 14 gauge through 1 gauge conductors
-
70°C when terminated to equipment for circuits rated over 100 Amps or marked for conductors larger than 1 gauge
-
90°C wet or dry locations
-
For dwelling units, conductors shall be permitted at listed ampacities to be utilized as 120/240 volt, 3-wire, single-phase service conductors that supply the total load
-
UL 44, 854
-
Federal Specification J-C - 30B
Construction
Conductors:
The "1/0-1/0-2" designation means this SEU cable contains three conductors:
- Two phase conductors (hot wires) sized 1/0 AWG for carrying current.
- One neutral conductor, which also serves as the ground conductor, sized 2 AWG.
- The conductors are cabled together with a bare aluminum neutral/ground conductor.
- A reinforced binder tape holds the assembly together.
All conductors are made of compact stranded 8000 series aluminum, providing lightweight properties, corrosion resistance, and high electrical conductivity.
Insulation:
Each insulated conductor is coated with XHHW-2 cross-linked polyethylene (XLPE) insulation, which provides:
- High heat resistance (rated up to 90°C).
- Moisture resistance for dry locations.
- Durability against mechanical stress and chemical exposure.
Jacket:
The cable jacket used in its design is Polyvinyl Chloride (PVC). The jacket protects the inner components of the cable from potentially damaging external forces. PVC is robust and resistant to oil, sunlight, water, flames, acids, chemicals, radiation, impact, abrasion, and weather changes. Sequential footage markings that help the user identify the appropriate length during installation are noted on the cable jacket.
Specifications:
-
Insulated Cond(s) Size AWG: 1/0
-
Bare Conductor Size AWG: 2
-
Nominal O.D. Inches: 0.647
-
Approx. Weight lb/1000FT: 574 lbs
-
Ampacity at 90°C: 135 Amps
-
Ampacity in dwelling: 125 Amps
Compatible with Manufacturer |
|
Priority Wire & Cable : | 1/0-02ALUMG-R-SEU |
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet
Reviews
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460