A2181404 (4×AWG14+2×(2×AWG16)) Lutze Driveflex XLPE (C) Servo Ii Tsp PVC VFD Cable Shielded
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
A2181404 (4×AWG14+2×(2×AWG16)) LUTZE DRIVEFLEX® XLPE (C) Servo II TSP PVC VFD Cable Shielded
Allowable Ampacity for A2181404 (4×AWG14+2×(2×AWG16)) LUTZE DRIVEFLEX® XLPE (C) Servo II TSP PVC VFD Cable Shielded: 100 Amps
Application:
• Shielded multi-conductor cable for VFD and Motor applications to connect power from drives to motors
• Cable design for harsh industrial environments and operating conditions with high noise levels
• XLPE thick wall insulation with low capacitance, ideal for applications with high voltage spikes and long cable runs
• Compliant with NFPA 79 for wiring of industrial machinery
• TC-ER for use with cable trays without conduit, which can reduce material and labor costs
• WTTC – wind turbine tray cable rating for use in wind power generation
• Dry, damp or wet conditions
Also Known As:
A2181404 LÜTZE DRIVEFLEX® XLPE (C) Cable, A2181404 DRIVEFLEX® XLPE (C) Servo Cable, VFD XLPE (C)SE II PVC Cable, VFD Cable, PVC Cable, Lutze Cable, Silicone-free Cable, Tinned copper Cable, Flexible Cable
Characteristics:
• Flexible XLPE conductor design
• Non-wicking fillers
• Effective dual layer shield for EMC compliance
• Specially formulated jacket for oil resistance and easy strip design
• Low capacitance cable
• Sunlight resistant
• Direct burial
• UL Type TC-Exposed Run
• Talc free and silicone free
Standards:
Certifications:
• cULus
• TC-ER
• UL DP-1
• WTTC
• Class 1 Div. 2 per NEC
• Art. 336, 392, 501
• cUL TC
• CIC FT4
• UL 1277
• Wet/Dry
• P-07-KA130021-MSHA
Conformity:
• CE
• RoHS
Oil resistant according to:
• Oil Res II
Construction 1:
- • Element construction: AWG14/4C
- • Conductor construction: AWG 14 (41/30)
- • Conductor: AWG conductor
CU-wire tin-plated - • Conductor category: fine wire
- • Conductor marking: black with white number print green/yellow
- • Conductor insulation: XLPE, RHW-2
- • Stranding: strands braided together
Construction 2:
- • Element construction: AWG16/2TSP
- • Conductor construction: AWG 16 (26/30)
- • Conductor: AWG conductor
CU-wire tin-plated - • Conductor category: fine wire
- • Conductor marking: black with white number print
- • Conductor insulation: XLPE, XHHW-2
- • Stranding: conductors stranded in pairs
Overall Construction:
- • Drain wire: CU-wire tin-plated
- • Overall shield: foil shield tinned copper wires braid shield optical cover approx. 80%
- • Jacket characteristics: Oil resistant, Silicone-free
Technical data:
- • Rated voltage UN: 600 V TC-ER
1000 V Flexible VFD servo cable 90C
1000 V WTTC - • Temperature range fixed: -40 °C … +90 °C
- • Minimum bending radius fixed: 6×D
Technical Data 1:
• Element construction: AWG14/4C
Technical Data 2:
• Element construction: AWG16/2TSP
Specifications:
- • Number of conductors/cross-section: (4×AWG14+2×2×16)
- • Cross-section AWG: AWG 14
- • Cross-section, metric: 2.5 mm²
- • Jacket material: PVC
- • Jacket color: black RAL 9005
- • Outer Ø: 0.760 Inches
- • Weight: 346.5 Lbs
- • Cu-Index: 149 Lbs
- • Type: VFD XLPE (C)SE II PVC(4×AWG14+2×(2×AWG16))
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Reviews