6mm 1C Stranded Tinned Copper Unshielded XLPO Motor 1900/3300V Rail Ca
nassaunationalcable.com/es/collections/motor-stranded-tinned-copper-unshielded-xlpo-1900-3300v-rail-cable/products/6mm-1c-stranded-tinned-copper-unshielded-xlpo-motor-1900-3300v-rail-cable

Items in Cart ()

View cart

6mm 1C Stranded Tinned Copper Unshielded XLPO Motor 1900/3300V Rail Cable

6mm 1C Stranded Tinned Copper Unshielded XLPO Motor 1900/3300V Rail Cable
Roll over image to Zoom

6mm 1C Stranded Tinned Copper Unshielded XLPO Motor 1900/3300V Rail Cable

SKU: RAD-0060
motor-stranded-tinned-copper-unshielded-xlpo-1900-3300v-rail-cable

Availability: In stock

Min Length: 1 FT
Max Length: 10000 FT
Price:
Precio habitual
$1.96 /FT
Precio de oferta
$1.96 /FT
Los gastos de envío se calculan en la pantalla de pagos.
Free Shipping: On orders above $1000
La cantidad debe ser 1 o más

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Where are we? 4 Continents 8 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Chat

Live Chat: Bottom Right Corner!

Email Us

info@nassaunationalcable.com

Product Information

Specification

6mm 1C Stranded Tinned Copper Unshielded XLPO Motor 1900/3300V Rail Cable

Allowable Ampacity for 6mm 1C Stranded Tinned Copper Unshielded XLPO Motor 1900/3300V Rail Cable: 100 Amps

About:

• The Motor Stranded Tinned Copper Unshielded XLPO 1900/3300V Rail Cable is a high-voltage, durable cable designed primarily for use in the railway sector and industrial applications. It features stranded tinned copper conductors for improved conductivity and corrosion resistance, wrapped in a robust XLPO (Cross-Linked Polyolefin) insulation for excellent thermal, chemical, and mechanical protection. This cable is unshielded, indicating it's intended for environments where electromagnetic interference is not a major concern. Its construction makes it suitable for demanding applications, including power distribution and signaling in rail infrastructures, as well as connecting industrial motors. The 1900/3300V voltage rating signifies its capability to handle high-voltage requirements, ensuring reliable and safe operation in harsh environments..

Also Known As:

• This cable might be referred to by various names in the industry, emphasizing different aspects of its construction or application. It could be known for its voltage rating (1900/3300V), the insulation material (XLPO - Cross-Linked Polyolefin), or its use in rail and motor applications. The "Tinned Copper" indicates that the copper conductors have been coated with tin to prevent oxidation and improve conductivity.

Application:

Designed for traction and rolling stock these single-core cables are suitable for fixed installations within vehicles, jumper connections between vehicles and between motor and underframe. These cables are also designed for use in connections to coil windings, wiring of motor vehicles, control panels and switchgear and may also be used in high temperature zones.

Construction:

 In accordance with rail specification TDE/76/P/16.
 Conductor: Class 5 tinned copper conductors to BS EN 60228.
 Insulation: Grey cross-linked polyolefin insulation*
• Flame Retardant to BS EN 60332-3-22 (NMV 7) (IEC 60332-3-22 Category A)
 Voltage Rating: 1900/3300 V
Temperature Rating: : 90°C maximum conductor operating temperature (per TDE/76/P/16) May also be used at conductor temperatures up to and including 125°C
• Not recommended to be handled or installed at temperatures below 5°C

Standards:

This cable is manufactured and tested according to specific standards to ensure safety, reliability, and performance. Standards may include:

 IEC Standards: For electrical and performance characteristics.
 EN 50306: European standard for railway applications, if applicable.
 Fire Performance Standards: Specific standards that assess the cable's behavior in fire conditions, crucial for rail applications.

Features:

• High Voltage Capacity: Suitable for high-voltage applications, ensuring safe and efficient power distribution.
• Robust Insulation:
XLPO insulation provides excellent thermal, chemical, and mechanical protection.
• Corrosion Resistance:
Tinned copper conductors resist corrosion, ensuring longevity and reliability.
• Flexibility:
Despite its high voltage rating and robust insulation, the cable is designed to be flexible enough for installation in challenging environments.
• Fire Resistance:
Likely to have fire-resistant qualities, making it safe for use in public infrastructure like railways.

Specifications:

• Conductor Size: 6MM Squared
• Conductor Count: 1 Conductor
• Conductor Material: Tinned OR Coated Copper
• Conductor Type: Finely Stranded
• Insulation Material: XLPO-Cross-Linked Polyolefin
• Screen/Shield: Unshielded
• Voltage Range: 1900/3300V
• Weight kg/km: 80


*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color

Download PDF Spec Sheet

Reviews

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Get in Touch
Live Chat Get replies right away!
Email info@nassaunationalcable.com

Call Us: 1-516-482-6313    Text Us: 1-516-703-3460