LS E9MKT-A65B01CA00 500 MCM Strand Cu Filled 1/3 Reduced Neutral Shield LLDPE 345mils Series E9MK 35kV 100% MV-90 Primary UD Cable

LS E9MKT-A65B01CA00 500 MCM Strand Cu Filled 1/3 Reduced Neutral Shield LLDPE 345mils Series E9MK 35kV 100% MV-90 Primary UD Cable
Roll over image to Zoom

LS E9MKT-A65B01CA00 500 MCM Strand Cu Filled 1/3 Reduced Neutral Shield LLDPE 345mils Series E9MK 35kV 100% MV-90 Primary UD Cable

SKU:
ls-strand-copper-filled-shield-lldpe-345mils-series-e9mk-35kv-100-mv-90-primary-ud-cable

Select a Gauge

LS E9MKT-A65B01CA00 500 MCM Strand Cu Filled 1/3 Reduced Neutral Shield LLDPE 345mils Series E9MK 35kV 100% MV-90 Primary UD Cable
Min Length: 1 FT
Max Length: 10000 FT
Price:
Precio habitual
$0.00 /FT
Precio de oferta
$0.00 /FT
Los gastos de envío se calculan en la pantalla de pagos.
Free Shipping: On orders above $1000
La cantidad debe ser 1 o más

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Where are we? 4 Continents 8 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Chat

Live Chat: Bottom Right Corner!

Email Us

info@nassaunationalcable.com

Product Information

Specification

LS E9MKT-A65B01CA00 500 MCM Strand Cu Filled 1/3 Reduced Neutral Shield LLDPE 345mils Series E9MK 35kV 100% MV-90 Primary UD Cable

Allowable Ampacity for LS E9MKT-A65B01CA00 500 MCM Strand Cu Filled 1/3 Reduced Neutral Shield LLDPE 345mils Series E9MK 35kV 100% MV-90 Primary UD Cable: 100 Amps

Applications:

The Medium Voltage Primary Underground Distribution (UD) cables consist of an Copper (filled or unfilled) conductor, covered with treeretardant cross-linked polyethylene (TR-XLPE), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.

Also Known as:

UD Cable, LS Cable, E9MK Cable, Primary UD Cable, LS E9MK Cable, E9MK UD Cable

Description:

The Medium Voltage Primary Underground Distribution (UD) cables consist of an Copper (filled or unfilled) conductor, covered with treeretardant cross-linked polyethylene (TR-XLPE), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.

Features:

• High dielectric strength
• Low moisture absorption
• Low dielectric loss
• Excellent resistance to treeing
• Jacket is sunlight-resistant
• Designed to operate continuously at a conductor temperature
not exceeding
» 90°C for normal operations
» 130°C for emergency overload
» 250°C for short circuit

Specification:

AWG Size: 500 MCM
Conductor: Copper Filled
Jacket: Linear Low-Density Polyethylene (LLDPE)
Nominal Conductor Diameter¹ in (mm): 0.781 (19.8)
Nominal Insulation Diameter¹ in (mm): 1.54 (39.1)
Concentric Neutral No. x AWG: 26 x 12
Nominal Jacket Thickness¹ in (mm): 0.080 (2.04)
Nominal Overall Diameter¹ in (mm): 1.94 (49.2)
Nominal Net Weight: 3258 lbs/kft 
Voltage: 35kV
Part Number: E9MKT-A65B01CA00


*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color

Reviews

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Get in Touch
Live Chat Get replies right away!
Email info@nassaunationalcable.com

Call Us: 1-516-482-6313    Text Us: 1-516-703-3460