18 AWG 50P Stranded Bare Copper Al Tape PVC Gaalflex Instrumentation 6
nassaunationalcable.com/es/collections/gaalflex-stranded-bare-copper-al-tape-pvc-instrumentation-600-pos-tray-cable/products/18-awg-50p-stranded-bare-copper-al-tape-pvc-gaalflex-instrumentation-600-pos-tray-cable

Items in Cart ()

View cart

18 AWG 50P Stranded Bare Copper Al Tape PVC Gaalflex Instrumentation 600 POS Tray Cable

18 AWG 50P Stranded Bare Copper Al Tape PVC Gaalflex Instrumentation 600 POS Tray Cable
Roll over image to Zoom

18 AWG 50P Stranded Bare Copper Al Tape PVC Gaalflex Instrumentation 600 POS Tray Cable

SKU: 32141F7K502A18
gaalflex-stranded-bare-copper-al-tape-pvc-instrumentation-600-pos-tray-cable

Select a Gauge

18 AWG 50P Stranded Bare Copper Al Tape PVC Gaalflex Instrumentation 600 POS Tray Cable
Price:
Precio habitual
$0.00 /Qty
Precio de oferta
$0.00 /Qty
Los gastos de envío se calculan en la pantalla de pagos.
Free Shipping: On orders above $1000
La cantidad debe ser 1 o más

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Where are we? 4 Continents 8 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Chat

Live Chat: Bottom Right Corner!

Email Us

info@nassaunationalcable.com

Product Information

Specification

18 AWG 50P Stranded Bare Copper Al Tape PVC Gaalflex Instrumentation 600 POS Tray Cable

Allowable Ampacity for 18 AWG 50P Stranded Bare Copper Al Tape PVC Gaalflex Instrumentation 600 POS Tray Cable: 100 Amps

About:

The 18 AWG 50P Stranded Bare Copper Al Tape PVC Gaalflex Instrumentation 600 POS Tray Cable is an industrial-grade cable. It features a single pair of 18-gauge stranded bare copper wires for flexibility and good conductivity. The cable is shielded with aluminum tape to protect against electromagnetic interference and is insulated with durable PVC. This cable is designed for use in industrial environments, particularly in tray systems, and is rated for 600-volt applications.

Also Known As:

 • 18 AWG Al Shielded PVC Instrumentation Cable.
• 18 AWG PVC Insulated Industrial Tray Cable.

Application:

• Instrumentation and Control Systems: Commonly used in the control and instrumentation systems within industrial settings.
 Cable Tray Installations:
Suitable for use in cable trays, particularly in industrial environments where EMI protection is crucial.
 Factory Automation: Employed in automation systems where precise control and uninterrupted signal integrity are essential.
 Industrial Process Control Networks:
Ideal for wiring in process control networks, catering to various industrial needs.

Standards:

Likely meets industrial standards like UL or NEC, ensuring safety and performance in tray cable applications.
 Designed to meet the requirements for 600V applications, adhering to industry-specific safety and performance standards.

Construction:

 Conductor: Stranded Red Copper, Acc.to Astm B-3, Class B And Astm B-8
 Insulation: 
Special Pvc/nylon Type Tfn Acc. To Ul 66, Flame-retardant 90°c
 Colour Cores:
 Acc. To Icea Table E1: Pairs: Black And White Numbered
 Stranding: 
In Pairs
 Screen: 
Aluminium Tape + Petp Foil, + Tinned Copper Drain Wire
 Ripcord: 
Nylon Ripcord Under Outer Sheath
 Outer Sheath: 
Black (Ral 9005), Special Pvc Compound, Flame Retardant And Uv Resistance

Features:

• Cable For Tray Use
• Outdoor Use
• Sunlight Moisture And Weather Resistance
• Oil And Gasoline Resistance Due To Pvc/nylon Insulation
• Direct Burial
• Lead Free
• Suitable For Use In Cable Trays, Raceways, Conduit Or For Aerial Applications Where Installed With A Messenger
• Type Tc Acc. To Nec 2008 And Nec 2011 Article 336
• Suitable In Class I Division 2 And Class 2 Division 2 Hazardous Locations And Intrinsically Safe Application Acc. To Nec 2008 And Nec 2011 Articles 392, 501, 502, 503, 505
• Suitable In Class 1 Circuits, Acc. To Nec 2008 And Nec 2011 Articles 336.10 And 725 For Type Tc Cables
• Suitable For Nonpower-limited Alarm Circuits Acc. To Nec 2008 And Nec 2011 Articles 336.10 And 760.46
• On Request Tinned Copper Conductors
• On Request Welded And Corrugated Aluminium Armor And Pvc Outer Sheath
• On Request Interlocked Aluminium Armour With Or Without Pvc Outer Sheath
• On Request Rohs And Ce Approval

Specifications:

• No.of cores x cross section n x AWG: 50 x 2 x 18
• Outer-Ø inches ± 10%: 1,396
• Nominal voltage UL: 600 V
• Test voltage: 4 kV
• Temperature range UL:  Dry: up to +90°C Wet: up to +75°C
• Min. bending radius: Fixed laying: 5 x d During Installation: 8 x d
• Cable weight approx. Lbs/Mft : 1017
• Part Number: 32141F7K502A18


*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color

Download PDF Spec Sheet

Reviews

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Get in Touch
Live Chat Get replies right away!
Email info@nassaunationalcable.com

Call Us: 1-516-482-6313    Text Us: 1-516-703-3460