20 AWG 12P Bare / Tinned copper Shielded Al Tape CPR PVC FR2XHOHR Inst
nassaunationalcable.com/es/collections/fr2xhohr-bare-tinned-copper-shielded-al-tape-cpr-pvc-instrumentation-cable/products/20-awg-12p-bare-tinned-copper-shielded-al-tape-cpr-pvc-fr2xhohr-instrumentation-cable

Items in Cart ()

View cart

20 AWG 12P Bare / Tinned copper Shielded Al Tape CPR PVC FR2XHOHR Instrumentation Cable

20 AWG 12P Bare / Tinned copper Shielded Al Tape CPR PVC FR2XHOHR Instrumentation Cable
Roll over image to Zoom

20 AWG 12P Bare / Tinned copper Shielded Al Tape CPR PVC FR2XHOHR Instrumentation Cable

SKU: 47020D.X122M05
fr2xhohr-bare-tinned-copper-shielded-al-tape-cpr-pvc-instrumentation-cable

Select a Gauge

20 AWG 12P Bare / Tinned copper Shielded Al Tape CPR PVC FR2XHOHR Instrumentation Cable
Price:
Precio habitual
$0.00 /Qty
Precio de oferta
$0.00 /Qty
Los gastos de envío se calculan en la pantalla de pagos.
Free Shipping: On orders above $1000
La cantidad debe ser 1 o más

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Where are we? 4 Continents 8 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Chat

Live Chat: Bottom Right Corner!

Email Us

info@nassaunationalcable.com

Product Information

Specification

20 AWG 12P Bare / Tinned copper Shielded Al Tape CPR PVC FR2XHOHR Instrumentation Cable

Allowable Ampacity for 20 AWG 12P Bare / Tinned copper Shielded Al Tape CPR PVC FR2XHOHR Instrumentation Cable: 100 Amps

About:

This instrumentation cable features 20 AWG size, making it suitable for detailed control signals and communications within various instrumentation setups. It is designed with two conductors (12P), which can be either bare or tinned copper, providing flexibility and resistance to corrosion. The cable includes aluminum tape shielding and is enveloped in a flame-retardant (FR), halogen-free (HOHR), polyvinyl chloride (PVC) sheath, adhering to the Construction Products Regulation (CPR) for building materials in the EU.

Also Known As:

 Shielded Instrumentation Cable
 FR2XHOHR PVC Instrumentation Cable
 20 AWG Control Cable
 CPR-Compliant Communication Cable

Application:

 Industrial automation and process control systems, connecting sensors, actuators, and other devices for precise operation.
 Building management systems (BMS), where it ensures reliable signal transmission for HVAC, lighting, security, and other subsystems.
 Energy sector, including power plants and distribution networks, for monitoring and control.
 Infrastructure and transportation projects, where dependable communication lines are essential for safety and efficiency.

Standards:

 Complies with CPR (Construction Products Regulation) for fire safety and performance in construction applications within the EU.
 Adheres to relevant industry standards for instrumentation cables, such as those from the IEC or similar regulatory bodies.
 Meets flame retardant and halogen-free requirements, ensuring minimal toxic gas emission and smoke in the event of a fire.

Construction:

• Conductor: Flexible red or tinned copper conductor Cl.5, acc. to IEC 60228
 Insulation: PVC, type R2
 Colour cores: Pair(s): blue-black, with black progressively numbered
                          Triad(s): blue-brown-black, with black progressively numbered
 Stranding: Conductors twisted in pairs-triads, pairs-triads twisted in concentric layers
 Screen: Individual: electrostatic screen of plastic and aluminium tape + tinned drain-wire
                Overall: 
electrostatic screen of plastic and aluminium tape + tinned drain-wire

• Outer Sheath: Black (RAL 9005),blue (RAL 5015) or grey (RAL 7001), PVC type RZ

Features:

 Acc. to CPR UE 305/11, EN 50575:2014 + A1:2016, Eca
 Classification (CEI UNEL 35016), EN 13501-6

Specifications:

• No. of pairs/triples x cross section n x mm²: 12x2x0,50
• Outer-Ø ca.mm ± 10%: 14
• Copper Weight kg/km: 177,6
• Inductance L (μH/m): 0,90

• Nominal Voltage: up to 0,75 mm2: Uo/U 300/500 V
                                  from 1 mm2: Uo/U 450/750 V

• Test Voltage: up to 0,75 mm2: 2 kV
                          from 1 mm2: 2,5 kV

• Temperature range: - 10° C up to + 70° C
• Min. bending radius: 10 x d

• Cable Weight approx. kg/km: 295
• Part Number: 47020D.X122M05


*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color

Download PDF Spec Sheet

Reviews

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Get in Touch
Live Chat Get replies right away!
Email info@nassaunationalcable.com