6/2 UF-B Stranded Copper Underground Feeder Cable 600V
nassaunationalcable.com/es/collections/all/products/6-2-uf-b-stranded-copper-underground-feeder-cable-600v

Items in Cart ()

View cart

6/2 UF-B Stranded Copper Underground Feeder Cable 600V

6/2 UF-B Stranded Copper Underground Feeder Cable 600V
Roll over image to Zoom

6/2 UF-B Stranded Copper Underground Feeder Cable 600V

SKU: NNC3750X
underground-feeder-cable-uf-b-copper-600v

Availability: In stock

Min Length: 1 FT
Max Length: 10000 FT
Price:
Precio habitual
$5.00
Precio de oferta
$2.73 /FT 45% off
Los gastos de envío se calculan en la pantalla de pagos.
Free Shipping: On orders above $1000
La cantidad debe ser 1 o más

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

Based on 36 reviews
92%
(33)
8%
(3)
0%
(0)
0%
(0)
0%
(0)
T
Terry Banzhaf
Wire

look to be quality product

V
Victor Bischoff
wire

excellant service & product

T
TD
Great product

The cable was very easy to work with and great customer service.

J
Jay Klingensmith

6/2 Underground Feeder Cable UF-B Copper 600V

T
Thomas Dyra

Your service with delivery and order was very good. Just got it in and hooked up yesterday. Time will tell on your wire on how well it works and how long it lasts. Thank you again

Where are we? 4 Continents 8 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Chat

Live Chat: Bottom Right Corner!

Email Us

info@nassaunationalcable.com

Product Information

Specification

6/2 UF-B Stranded Copper Underground Feeder Cable 600V

Allowable Ampacity for 6/2 Underground Feeder Cable UF-B Copper 600V
(Direct Burial): 55

Applications:

An underground feeder cable's prime purpose is to bring the power from the residential, commercial, and industrial buildings to outdoor constructions, which include pumps and lighting constructions. The electrical cable is suitable for direct burial, as well as direct exposure to the sunlight. It is permitted for use as feeder or branch circuit cable if provided with overcurrent protection. Copper Underground Feeder Cable UF-B has a rating of 600 volts.

Also Known As: 

6/2 Copper Underground Feeder Cable, 6/2 Copper Direct Burial Feeder Cable, 6/2 Branch Circuit Wiring Cable, 6/2 UF-B Wire, 6/2 Copper Direct Earth Burial Cable, 6/2 Copper Branch Circuit Cable, 6/2 UF-B Direct Burial Wire, direct burial cable, 6 2 uf wire

Standards:

  • Ul Standard 493 for Thermoplastic-Insulated Underground Feeder and Branch Circuit Cables
  • For use in interior wiring in wet, dry or corrosive locations under recognized wiring methods of the National Electrical Code (NEC)
  • Acceptable to be installed as a Non-Metallic Sheathed Cable following NEC Article 339-3 (4)
  • Acceptable for use per NEC Articles 300-4(b) and 339
  • ASTM - B3 and B-8
  • UL Standard 83
  • Federal Specification A-A-59544
  • RoHS/ REACH


Construction:

Conductor:

UF-B wire has solid or stranded Type THHN/THWN that are laid parallel with an uninsulated grounding conductor. The conductors are made of stranded annealed bare copper.

Insulation:

The cable is insulated with a PVC jacket with a nylon covering. It is resistant to moisture, grease, corrosion, sunlight, and chemicals.

Specifications:

  • Size AWG: 6
  • Weight per 1,000 ft: 303 lbs
  • Outside Diameter: 770X338
  • Conductors: 2
  • Number of Strands: 7
  • Jacket: PVC
  • Insulation and Jacket Thickness: 35 mils
  • Jacket Thickness: 45 mils
  • Ground Size: 10

    Compatible with Manufacturer

    Service Wire & Co : UFB6/2G
    Southwire : 214692

    *Data provided on this page is subject to change based on different manufacturers' variances
    ** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
    In the case the material only comes in a predetermined color or doesn’t come with any color

Download PDF Spec Sheet

FAQ's

What is UF-B Wire?

UF-B wire (Underground Feeder - Type B) is an electrical wire used for direct burial in the ground without needing additional conduit. It's water-resistant, sunlight-resistant, and suitable for outdoor and underground applications, particularly for powering outbuildings and exterior lighting.

What are the particular applications of 6/2 UF-B Cable?

 6/2 UF-B Cable is for higher current applications, such as:

  • Heavy-duty outdoor appliances (240V HVAC units)
  • Feeding subpanels in garages
What is the difference between UF-B wire with or without ground?

UF-B wire with ground is used for applications where additional safety is needed, such as when the wire is exposed to moisture. UF-B without ground can be used when local codes don't require grounding (f.e. lighting circuit where local code allows it).

What is UF-B cable permitted for use?

Article 340 of the NEC permits UF-B cable to be used for direct burial without the conduit. It also allows it for wet, damp, and corrosive locations. It can also be used above ground if UV-resistant and in conduit. UF-B is suitable for branch and feeder circuits for outbuilding and exterior applications.

Can UF-B wire be used indoors?

You can use UF-B indoors, but this is not a common practice. NEC does not ban UF-B indoors, but NM-B and THHN in conduit are more common interior cables that are easier to install.

What is the difference between UF and UF-B Wire?

UF-B is a modernized version of the UF cable with better moisture, corrosion, and sunlight resistance. Most of the underground feeder cables currently sold in stores are UF-B.

Can UF-B be buried?

The cable is designed to be buried. The standard burial depth is 24 inches.

Can UF-B wire be put in conduit?

It is possible to run UF-B through PVC or metal conduit for underground applications, but THWN is a preferable option as it is easier to install.

Can UF-B wire be exposed?

UF-B wire can be exposed if it is UV-resistant and not subject to physical damage.

How to strip UF-B wire?
  • Turn off the power for safety.
  • Slice the gray outer jacket carefully without cutting the inner wires.
  • Peel back the jacket to expose the insulated wires.
  • Use wire strippers to remove the insulation from the ends of each wire, typically about 3/4 inch.
  • If there's a ground wire, strip it similarly if insulated.

Reviews

Customer Reviews

Based on 36 reviews
92%
(33)
8%
(3)
0%
(0)
0%
(0)
0%
(0)
T
Terry Banzhaf
Wire

look to be quality product

V
Victor Bischoff
wire

excellant service & product

T
TD
Great product

The cable was very easy to work with and great customer service.

J
Jay Klingensmith

6/2 Underground Feeder Cable UF-B Copper 600V

T
Thomas Dyra

Your service with delivery and order was very good. Just got it in and hooked up yesterday. Time will tell on your wire on how well it works and how long it lasts. Thank you again

Get in Touch
Live Chat Get replies right away!
Email info@nassaunationalcable.com

Call Us: 1-516-482-6313    Text Us: 1-516-703-3460