Buy 6 AWG XHHW-2 Stranded Copper Building Wire
nassaunationalcable.com/en-ca/products/buy-6-awg-xhhw-2-stranded-copper-building-wire
Items in Cart ()
View cart

6 AWG XHHW-2 Stranded Copper Building Wire

750 MCM XHHW-2 COPPER BUILDING WIRE
Roll over image to Zoom
6 AWG XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
6 AWG XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
6 AWG XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
6 AWG XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
6 AWG XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
6 AWG XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
6 AWG XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
6 AWG XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
6 AWG XHHW-2 Stranded Copper Building Wire
SKU: NNC2390X
xhhw-2-copper-building-wire-conductor

Availability: In stock

Min Length: 25 FT
Max Length: 10000 FT
Price:
Regular price
$1.51 /FT
Sale price
$1.51 /FT
Shipping Cost Calculated at Checkout. Standard Lead Time is 1 to 6 Business Days.
Free Shipping: On orders above $1000
Quantity must be 1 or more

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

Based on 13 reviews
92%
(12)
8%
(1)
0%
(0)
0%
(0)
0%
(0)
H
Henri Buettner

6 AWG XHHW-2 Stranded Copper Building Wire

d
david banzhoff
Wire

Great product, fast service

J
Jared Ray

Good wire at a good price

Where are we? 4 Continents 9 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Product Information
Specification

6 AWG XHHW-2 Stranded Copper Building Wire

Description:

Copper SIMpull XHHW-2/RW90 conductors are primarily used in conduit, cable trays, or other recognized raceways for services, feeders, and branch circuit wiring, as specified in the National Electrical Code (NEC). These conductors are rated for wet and dry locations, with a maximum operating temperature of 90°C. The voltage rating is 600V or 1000V for all sizes. This cable is designed for easier installation without the need for pulling lubricant. RW90 is suitable for open wiring and use in raceways (except cable troughs and ventilated flexible cableways) in wet or dry locations, as per the Canadian Electrical Code. Conductor sizes 8 AWG and larger are rated for 600V or 1000V single conductor copper with XLPE insulation and SIMpull technology for easier pulling.

Also Known As:

6 XHHW-2 Copper Building Wire, 6 XHHW Cable, 6 XHHW Service Wire, 6 XHHW Copper Wire, 6 CU Building Wire, 6 Black Stranded CU SIMpull XHHW-2 Wire, Southwire 11296199, Southwire Wire, 6 AWG XHHW Building Wire, 6 Gauge Green Stranded Copper XHHW-2 Wire, 6 AWG Copper XHHW Wire, 6 AWG Electrical XHHW-2 Cable, 6 Gauge Stranded XHHW-2, 6 AWG Insulated Copper Wire.

Common Uses of 6 AWG Copper XHHW-2 Wire

  • 65A branch circuits in commercial and industrial buildings (75°C rating)
  • 75A feeder wiring in raceways and conduit where 90°C ampacity is permitted
  • Main power feeders in commercial, industrial, and residential service panels
  • Motor leads for large equipment requiring 600V-rated copper conductors
  • HVAC system wiring for high-power air conditioning units
  • Backup generator connections for emergency power supply
  • Cable tray wiring where NEC allows XHHW-2 conductors
  • 60A circuits for 48A Level 2 EV chargers
  • 60A feeders to garage, workshop, and pool equipment subpanels
  • 50A and 60A circuits for hot tubs, spas, and electric furnace heat strips
  • Underground conduit runs to detached garages and outbuildings

6 AWG XHHW-2 Copper Data Center Applications

In data centers, 6 AWG copper XHHW-2 is pulled in conduit and flexible metal conduit for rack branch circuits. NEC 210.19 sizes these circuits at 125% of the continuous load, and the 90°C rating gives headroom when many circuits share one raceway.

  • 60A, 208V three-phase circuits to high-density racks with IEC 60309 or CS8365 receptacles, about 17.3 kW at 80% loading

  • 60A, 415V three-phase rack circuits, about 34.5 kW at 80% loading

  • Feeds to in-row cooling units

  • Whips from remote power panels, in flexible metal conduit under raised floors (NEC 645.5(E))

Construction:

Conductor:

  • Material: Class B compressed stranded bare copper per ASTM B3 and ASTM B8

Insulation:

  • Material: Cross-linked polyethylene (XLPE) with SIMpull Technology
  • Properties: Silicone-free, abrasion-resistant, high-heat, moisture-resistant

Features:

  • SIS - 8 AWG and larger
  • Sunlight resistant
  • -40°C cold bend resistance
  • FT1 flame test rating
  • Gasoline and oil resistant II
  • CT Rated - 1/0 AWG and larger
  • FT4 flame test - 350 kcmil and larger
  • RoHS/REACH compliant

Standards & Compliance:

  • ASTM B3 – Soft or Annealed Copper Wire
  • ASTM B8 – Concentric-Lay-Stranded Copper Conductors
  • ASTM B787 – 19 Wire Combination Unilay-Stranded Copper Conductors
  • UL 44 – Thermoset-Insulated Wires and Cables
  • UL 1685 – Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger)
  • CSA C22.2 No. 38 – Thermoset-insulated wires and cables
  • ICEA S-95-658 (NEMA WC70) – Power Cables Rated 2000V or Less
  • IEEE 1202/FT4 Flame Test – (70,000 BTU/hr) 350kcmil and Larger
  • Buy American & Buy America Act (BAA) Compliant (49 U.S.C. § 5323(j) and 49 C.F.R. part 661)
  • Federal Specification A-A-59544
  • NMX-J-451-ANCE – Thermoset insulated wires and cables
  • NOM-063-SCFI – Electrical Conductors Safety Requirements

Specifications:

  • Size: 6 AWG
    Number of Strands: 7
    Diameter Over Conductor (Inches): 0.177
    Insulation Thickness (mils): 45
    Approx. OD (Inches): 0.274
    Min Bending Radius: 1.1 inch
    Max Pull Tension: 209 lbs
    Copper Weight (lbs/mft): 81 lbs
    Net Weight (lbs/mft): 97 lbs
    Allowable Ampacity At 60°C: 55 Amps
    Allowable Ampacity At 75°C: 65 Amps
    Allowable Ampacity At 90°C: 75 Amps
    Southwire Part (SIMpull): 11296199

Manufacturer Equivalents

Advanced Digital : 

Black : 208
White : 208W
Red : 208RD

Green : 208GN

Aetna Digital : 

Black : 117-4400C
Green : 117-4405

Draka : 

Black : 6200110bk
White : 6200110wh
Red : 6200110rd

Green : 6200546gn

General Cable : 

Black : 798751

Kalas : Black : t.b.d.
White : t.b.d.
Red : t.b.d.

Green : t.b.d.

Omni Cable :

Black : M708ST-01
White : M708ST-02
Red : M708ST-03
Green : M708ST-04

Southwire :

Black : 11296199


*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet

FAQ's

What is 6 AWG copper XHHW-2 used for?

XHHW-2 is single-conductor building wire with cross-linked polyethylene (XLPE) insulation, which is where the "X" in its name comes from. "HHW" stands for high heat and water resistance, and "-2" means it's rated 90°C in wet locations as well as dry. 6 AWG copper XHHW-2 is installed in conduit or other NEC-recognized raceways at up to 600V and is rated 65A at 75°C. It's used for 60A circuits for 48A EV chargers, garage and pool equipment subpanels, hot tubs, and electric furnace heat strips.

What are the main differences between XHHW and XHHW-2 wires?

Both use cross-linked polyethylene (XLPE) insulation and are rated 600V. The difference is the wet rating. XHHW is rated 90°C in dry locations but only 75°C in wet locations. XHHW-2 is rated 90°C in both, and it passes stricter UL 44 moisture testing. XHHW-2 can be used anywhere XHHW is allowed.

What is the difference between THHN and XHHW-2 wire?

Both THHN/THWN-2 and XHHW-2 are 600V building wires rated 90°C in wet and dry locations, so the real difference is the insulation. THHN/THWN-2 has thin PVC insulation with a nylon jacket. XHHW-2 has a single, thicker layer of cross-linked polyethylene (XLPE), a thermoset material that doesn't melt. XHHW-2 holds up better to abrasion, moisture, and cold. THHN/THWN-2 has a smaller diameter, so more conductors fit in the same conduit, and it usually costs less.

Can XHHW-2 wire be buried underground?

Not directly. XHHW-2 is not rated for direct burial, so it can't go in a trench without conduit. It can be installed underground inside conduit, because underground raceways are wet locations and XHHW-2 is rated 90°C wet. For burial without conduit, use a direct burial cable such as USE-2 or URD.

Does XHHW-2 wire have to be run in conduit?

Yes, in standard building installations. XHHW-2 is a single-conductor building wire meant for conduit or other recognized raceways. It can't be run exposed outdoors or fished through walls like NM cable, so inside a wall it has to be in conduit, such as EMT or flexible metal conduit. The NEC allows a few exceptions, such as cable tray for 1/0 AWG and larger conductors with a CT marking, or open wiring on insulators, but these are uncommon.

Is XHHW-2 wire sunlight resistant?

Yes. NNC's XHHW-2 is marked sunlight resistant, so it holds up in conduit runs exposed to the sun and where the wire leaves the conduit, such as at a weatherhead. Sunlight resistance doesn't replace the conduit requirement.

Can XHHW-2 wire be used in cold weather?

Yes. XLPE insulation stays flexible in the cold much better than PVC-insulated THHN, which makes XHHW-2 easier to pull in winter. It's commonly rated for installation down to -40°C (-40°F). Check the spec sheet for the exact minimum.

Can XHHW-2 be used as PV wire?

Yes, for the parts of a solar system that run in conduit. XHHW-2 is widely used in PV installations for DC home runs from the array to the inverter and for AC circuits from the inverter to the panel, as long as the system voltage stays within its 600V rating. It doesn't replace PV wire in exposed array wiring between modules, where NEC 690.31 calls for PV wire or USE-2.

Is 6 AWG copper XHHW-2 used in data centers?

Yes. 6 AWG copper XHHW-2 feeds 60A three-phase circuits to high-density racks, about 17.3 kW at 208V or 34.5 kW at 415V at 80% loading. It's also used for feeds to in-row cooling units.

Reviews

Customer Reviews

Based on 13 reviews
92%
(12)
8%
(1)
0%
(0)
0%
(0)
0%
(0)
H
Henri Buettner

6 AWG XHHW-2 Stranded Copper Building Wire

d
david banzhoff
Wire

Great product, fast service

J
Jared Ray

Good wire at a good price

Get in Touch
Live Chat Get replies right away!
Email info@nassaunationalcable.com

Call Us: 1-516-482-6313    Text Us: 1-516-703-3460