2 AWG XHHW-2 Stranded Copper Building Wire
nassaunationalcable.com/en-ca/products/2-awg-xhhw-2-stranded-copper-building-wire
Items in Cart ()
View cart

2 AWG XHHW-2 Stranded Copper Building Wire

750 MCM XHHW-2 COPPER BUILDING WIRE
Roll over image to Zoom
2 AWG XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
2 AWG XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
2 AWG XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
2 AWG XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
2 AWG XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
2 AWG XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
2 AWG XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
2 AWG XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
2 AWG XHHW-2 Stranded Copper Building Wire
SKU: NNC2417X
xhhw-2-copper-building-wire-conductor

Availability: In stock

Price:
Regular price
$3.44 /FT
Sale price
$3.44 /FT
Shipping Cost Calculated at Checkout. Standard Lead Time is 1 to 6 Business Days.
Free Shipping: On orders above $1000
Quantity must be 1 or more

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

Based on 6 reviews
83%
(5)
17%
(1)
0%
(0)
0%
(0)
0%
(0)
W
Willie

Fast shipping great customer service

B
Brandon Avery
Good product, SLOW shipping, misleading inventory

Wire took twice as long as originally quoted and the items I ordered turned out to NOT be in stock meaning I had to pay an extra $150 to get them ordered in rom a different supplier. Had I of known that I would have picked a different wire but was stuck waiting instead delaying my project.

L
Larry Wade

2 AWG XHHW-2 Copper Building Wire

Where are we? 4 Continents 9 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Product Information
Specification

2 AWG XHHW-2 Stranded Copper Building Wire

Description:

Copper SIMpull XHHW-2/RW90 conductors are primarily used in conduit, and other recognized raceways for services, feeders, and branch circuit wiring, as specified in the National Electrical Code (NEC). These conductors are rated for wet and dry locations, with a maximum operating temperature of 90°C. The voltage rating is 600V or 1000V for all sizes. This cable is designed for easier installation without the need for pulling lubricant. RW90 is suitable for open wiring and use in raceways (except cable troughs and ventilated flexible cableways) in wet or dry locations, as per the Canadian Electrical Code.

Also Known As:

2 XHHW-2 Copper Building Wire, 2 XHHW Cable, 2 XHHW Service Wire, 2 XHHW Copper Wire, 2 CU Building Wire, 2 Black Stranded CU SIMpull XHHW-2 Wire, Southwire 11298799, Southwire Wire, 2 AWG XHHW Building Wire, 2 Gauge Black Stranded Copper XHHW-2 Wire, 2 Stranded Copper XHHW-2 Wire, 2 AWG Copper XHHW Wire, 2 AWG Insulated Copper XHHW-2, 2 Gauge Electrical XHHW-2 Cable.

Common Uses of 2 AWG Copper XHHW-2 Wire

2 AWG copper XHHW-2 is installed in conduit and other NEC-recognized raceways for services, feeders, and branch circuits, in wet or dry locations at up to 600V. It's rated 115A at 75°C and 130A at 90°C. Typical uses:

  • 125A home services under NEC 310.12

  • 110A commercial feeders and subpanels

  • 100A feeders on long runs, where the larger size limits voltage drop

  • Feeders for welders and three-phase machinery

Construction:

Conductor:

  • Material: Class B compressed stranded bare copper per ASTM B3 and ASTM B8

Insulation:

  • Material: Cross-linked polyethylene (XLPE) with SIMpull Technology
  • Properties: Silicone-free, abrasion-resistant, high-heat, moisture-resistant

Features:

  • SIS - 8 AWG and larger
  • Sunlight resistant
  • -40°C cold bend resistance
  • FT1 flame test rating
  • Gasoline and oil resistant II
  • CT Rated - 1/0 AWG and larger
  • FT4 flame test - 350 kcmil and larger
  • RoHS/REACH compliant

Standards & Compliance:

  • ASTM B3 – Soft or Annealed Copper Wire
  • ASTM B8 – Concentric-Lay-Stranded Copper Conductors
  • ASTM B787 – 19 Wire Combination Unilay-Stranded Copper Conductors
  • UL 44 – Thermoset-Insulated Wires and Cables
  • UL 1685 – Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger)
  • CSA C22.2 No. 38 – Thermoset-insulated wires and cables
  • ICEA S-95-658 (NEMA WC70) – Power Cables Rated 2000V or Less
  • IEEE 1202/FT4 Flame Test – (70,000 BTU/hr) 350kcmil and Larger
  • Buy American & Buy America Act (BAA) Compliant (49 U.S.C. § 5323(j) and 49 C.F.R. part 661)
  • Federal Specification A-A-59544
  • NMX-J-451-ANCE – Thermoset insulated wires and cables
  • NOM-063-SCFI – Electrical Conductors Safety Requirements

Specifications:

Size: 2 AWG
Number of Strands: 7
Diameter Over Conductor (Inches): 0.282
Insulation Thickness (mils): 45
Approx. OD (Inches): 0.379
Copper Weight (lbs/mft): 204 lbs
Net Weight (lbs/mft): 228 lbs
Min Bending Radius: 1.5 inches
Max Pull Tension: 530 lbs
Allowable Ampacity At 60°C: 95 Amps
Allowable Ampacity At 75°C: 115 Amps
Allowable Ampacity At 90°C: 135 Amps
Southwire Part (SIMpull): 11298799

Compatible with Manufacturer

Advanced Digital : 

202

Omni Cable :

Black : M702ST-01
White : M702ST-02
Red : M702ST-03
Green : M702ST-04
Blue : M702ST-05
Gray : M702ST-06
Orange : M702ST-07
Yellow : M702ST-08
Purple : M702ST-09
Brown : M702ST-10
Pink : M702ST-11
Tan : M702ST-12

Southwire :

Black : 11298799
White : 21810799
Red : 21811599
Blue : 55308799
Green : 47412202

Yellow : 55309008
Orange : 55308908
Brown : 55308808
Gray : 55309199

HWC : 

HW00200201

Priority Wire & Cable : 

2STRXHHW

Service Wire Co : 

XH2BK


*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet

FAQ's

What is 2 AWG copper XHHW-2 used for?

XHHW-2 is single-conductor building wire with cross-linked polyethylene (XLPE) insulation, which is where the "X" in its name comes from. "HHW" stands for high heat and water resistance, and "-2" means it's rated 90°C in wet locations as well as dry. 2 AWG copper XHHW-2 is installed in conduit or other NEC-recognized raceways at up to 600V and is rated 115A at 75°C. It's used for 125A home services, 110A commercial feeders, long 100A runs, and welder and machinery feeders.

What are the main differences between XHHW and XHHW-2 wires?

Both use cross-linked polyethylene (XLPE) insulation and are rated 600V. The difference is the wet rating. XHHW is rated 90°C in dry locations but only 75°C in wet locations. XHHW-2 is rated 90°C in both, and it passes stricter UL 44 moisture testing. XHHW-2 can be used anywhere XHHW is allowed.

What is the difference between THHN and XHHW-2 wire?

Both THHN/THWN-2 and XHHW-2 are 600V building wires rated 90°C in wet and dry locations, so the real difference is the insulation. THHN/THWN-2 has thin PVC insulation with a nylon jacket. XHHW-2 has a single, thicker layer of cross-linked polyethylene (XLPE), a thermoset material that doesn't melt. XHHW-2 holds up better to abrasion, moisture, and cold. THHN/THWN-2 has a smaller diameter, so more conductors fit in the same conduit, and it usually costs less.

Can XHHW-2 wire be buried underground?

Not directly. XHHW-2 is not rated for direct burial, so it can't go in a trench without conduit. It can be installed underground inside conduit, because underground raceways are wet locations and XHHW-2 is rated 90°C wet. For burial without conduit, use a direct burial cable such as USE-2 or URD.

Does XHHW-2 wire have to be run in conduit?

Yes, in standard building installations. XHHW-2 is a single-conductor building wire meant for conduit or other recognized raceways. It can't be run exposed outdoors or fished through walls like NM cable, so inside a wall it has to be in conduit, such as EMT or flexible metal conduit. The NEC allows a few exceptions, such as cable tray for 1/0 AWG and larger conductors with a CT marking, or open wiring on insulators, but these are uncommon.

Is XHHW-2 wire sunlight resistant?

Yes. NNC's XHHW-2 is marked sunlight resistant, so it holds up in conduit runs exposed to the sun and where the wire leaves the conduit, such as at a weatherhead. Sunlight resistance doesn't replace the conduit requirement.

Can XHHW-2 wire be used in cold weather?

Yes. XLPE insulation stays flexible in the cold much better than PVC-insulated THHN, which makes XHHW-2 easier to pull in winter. It's commonly rated for installation down to -40°C (-40°F). Check the spec sheet for the exact minimum.

Reviews

Customer Reviews

Based on 6 reviews
83%
(5)
17%
(1)
0%
(0)
0%
(0)
0%
(0)
W
Willie

Fast shipping great customer service

B
Brandon Avery
Good product, SLOW shipping, misleading inventory

Wire took twice as long as originally quoted and the items I ordered turned out to NOT be in stock meaning I had to pay an extra $150 to get them ordered in rom a different supplier. Had I of known that I would have picked a different wire but was stuck waiting instead delaying my project.

L
Larry Wade

2 AWG XHHW-2 Copper Building Wire