4 AWG XHHW-2 Stranded Copper Building Wire
Where are we? 4 Continents 9 Countries

Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Quick Support
4 AWG XHHW-2 Stranded Copper Building Wire
Description:
4 AWG copper XHHW-2 is installed in conduit and other NEC-recognized raceways for services, feeders, and branch circuits, in wet or dry locations at up to 600V. It's rated 85A at 75°C and 95A at 90°C. Typical uses:
-
100A home services: the standard copper size for a 100A residential service under NEC 310.12
-
80A feeders to subpanels
-
Large heat pump systems and air handlers with electric heat
-
Motor feeders for 480V three-phase equipment
Also Known As:
4 XHHW-2 Copper Building Wire, 4 XHHW Cable, 4 XHHW Service Wire, 4 XHHW Copper Wire, 4 CU Building Wire, 4 Black Stranded CU SIMpull XHHW-2 Wire, Southwire 11297999, Southwire Wire, 4 AWG XHHW Building Wire, 4 Gauge Green Stranded Copper XHHW-2 Wire, 4 Stranded Copper XHHW-2 Wire, 4 AWG Electrical XHHW-2 Cable, 4 AWG Copper XHHW Wire, 4 Gauge Insulated Copper XHHW-2 Wire, 100 amp wire, 100 amp cable
Construction:
Conductor:
- Material: Class B compressed stranded bare copper per ASTM B3 and ASTM B8
Insulation:
- Material: Cross-linked polyethylene (XLPE) with SIMpull Technology
- Properties: Silicone-free, abrasion-resistant, high-heat, moisture-resistant
Features:
- SIS - 8 AWG and larger
- Sunlight resistant
- -40°C cold bend resistance
- FT1 flame test rating
- Gasoline and oil resistant II
- CT Rated - 1/0 AWG and larger
- FT4 flame test - 350 kcmil and larger
- RoHS/REACH compliant
Standards & Compliance:
- ASTM B3 – Soft or Annealed Copper Wire
- ASTM B8 – Concentric-Lay-Stranded Copper Conductors
- ASTM B787 – 19 Wire Combination Unilay-Stranded Copper Conductors
- UL 44 – Thermoset-Insulated Wires and Cables
- UL 1685 – Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger)
- CSA C22.2 No. 38 – Thermoset-insulated wires and cables
- ICEA S-95-658 (NEMA WC70) – Power Cables Rated 2000V or Less
- IEEE 1202/FT4 Flame Test – (70,000 BTU/hr) 350kcmil and Larger
- Buy American & Buy America Act (BAA) Compliant (49 U.S.C. § 5323(j) and 49 C.F.R. part 661)
- Federal Specification A-A-59544
- NMX-J-451-ANCE – Thermoset insulated wires and cables
- NOM-063-SCFI – Electrical Conductors Safety Requirements
Specifications:
-
Size: 4 AWG
Number of Strands: 7
Diameter Over Conductor (Inches): 0.225
Insulation Thickness (mils): 45
Approx. OD (Inches): 0.321
Min Bending Radius: 1.3 inches
Max Pull Tension: 333 lbs
Copper Weight (lbs/mft): 128 lbs
Net Weight (lbs/mft): 148 lbs
Allowable Ampacity At 60°C: 70 Amps
Allowable Ampacity At 75°C: 85 Amps
Allowable Ampacity At 90°C: 95 Amps
Southwire Part (SIMpull): 11297999
|
Manufacturer Equivalents |
|
|
Advanced Digital : |
Black : 208 |
|
Aetna Digital : |
Black : 117-4400C |
|
Draka : |
Black : 6200110bk |
|
General Cable : |
Black : 798751 |
| Kalas : |
Black : t.b.d. White : t.b.d. Red : t.b.d. Green : t.b.d. |
|
Omni Cable : |
Black : M708ST-01 |
|
Southwire : |
Black : 11296199 |
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460