600 MCM XHHW-2 Stranded Copper Building Wire
nassaunationalcable.com/en-ca/products/600-mcm-xhhw-2-stranded-copper-building-wire
Items in Cart ()
View cart

600 MCM XHHW-2 Stranded Copper Building Wire

750 MCM XHHW-2 COPPER BUILDING WIRE
Roll over image to Zoom
600 MCM XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
600 MCM XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
600 MCM XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
600 MCM XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
600 MCM XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
600 MCM XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
600 MCM XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
600 MCM XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
600 MCM XHHW-2 Stranded Copper Building Wire
SKU: NNC2507X
xhhw-2-copper-building-wire-conductor

Availability: In stock

Price:
Regular price
$24.51 /FT
Sale price
$24.51 /FT
Shipping Cost Calculated at Checkout. Standard Lead Time is 1 to 6 Business Days.
Free Shipping: On orders above $1000
Quantity must be 1 or more

Enter the required footage in the quantity box - Cut to one length

Where are we? 4 Continents 9 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Product Information
Specification

600 MCM XHHW-2 Stranded Copper Building Wire

Allowable Ampacity (Per NEC Table 310.16):

  • 60°C: 350 Amps
  • 75°C: 420 Amps
  • 90°C (XHHW-2 Rating): 475 Amps

Description:

600 MCM XHHW-2 Copper Building Wire is a stranded conductor with cross-linked polyethylene (XLPE) insulation, designed for use in conduit, raceways, and feeders where high ampacity and durability are required. Rated for 600V, it operates in wet, dry, and corrosive environments, with a maximum temperature rating of 90°C.

Also Known As:

600 XHHW-2 Copper Building Wire, 600 XHHW Cable, 600 XHHW Service Wire, 600 XHHW Copper Wire, 600 MCM XHHW Wire, 600 MCM Copper XHHW-2 Cable, 600 MCM Electrical Wire, 600 MCM Stranded Copper XHHW-2.

Applications:

  • 400A feeders at full rating in a single run
  • 800A services run as two parallel sets
  • 1200A services run as three parallel sets
  • Main switchboard feeds in commercial and industrial buildings
  • Primary and secondary feeders in large commercial and industrial buildings
  • Underground conduit installations where moisture resistance is required
  • Main service conductors for high-load electrical panels
  • Backup generator wiring for hospitals, data centers, and critical facilities
  • Cable tray wiring in industrial settings requiring high ampacity

600 MCM XHHW-2 Copper Data Center Applications

In data centers, 600 MCM copper XHHW-2 is used for feeders between switchgear, UPS systems, PDUs, and panels. Data center loads run continuously, so NEC 215.2 sizes feeders at 125% of the load unless the breaker is 100% rated.

  • Two parallel sets for 800A switchboard and UPS feeders

  • Three parallel sets for 800 kVA UPS systems (962A full load, 1203A at 125%)

  • Feeders between main switchgear and UPS input boards

Construction:

Conductor:

  • Material: Annealed bare copper (concentrically stranded)
  • Properties: High conductivity, moisture resistance, and excellent durability

Insulation:

  • Material: Cross-linked polyethylene (XLPE)
  • Properties: Flame-retardant, resistant to chemicals, moisture, and abrasion

Standards & Compliance:

  • UL Standard 44 – Thermoset-Insulated Wires and Cables
  • ASTM B3 & B8 – Soft and Concentric-Lay-Stranded Copper Conductors
  • Federal Specification A-A-59544
  • RoHS/REACH Compliant
  • NEC Article 310.16 – Ampacity Ratings
  • ICEA S-95-658 (NEMA WC70) – Power Cables Rated 2000V or Less

Specifications:

  • Size: 600 MCM
    Number of Strands: 61
    Diameter Over Conductor (Inches): 0.865
    Insulation Thickness (mils): 80
    Weight per 1,000 ft: 1973 lbs
    Jacket: XLPE

Compatible with Manufacturer

Advanced Digital : 

20600CT

Omni Cable :

Black : M7600ST-01
White : M7600ST-02
Red : M7600ST-03
Green : M7600ST-04
Blue : M7600ST-05
Gray : M7600ST-06
Orange : M7600ST-07
Yellow : M7600ST-08
Purple : M7600ST-09
Brown : M7600ST-10
Pink : M7600ST-11
Tan : M7600ST-12

Southwire :

Black : 11309299
White : 55391399
Red : 55391499
Blue : 55391599
Green : 55391699

Yellow : 55392099
Orange : 55391999
Brown : 55391899
Gray : 55392199
Purple : 58921499

HWC : 

HW00260001

Service Wire Co : 

XH600BK


*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet

FAQ's

What is 600 MCM copper XHHW-2 used for?

XHHW-2 is single-conductor building wire with cross-linked polyethylene (XLPE) insulation, which is where the "X" in its name comes from. "HHW" stands for high heat and water resistance, and "-2" means it's rated 90°C in wet locations as well as dry. 600 MCM copper XHHW-2 is installed in conduit or other NEC-recognized raceways at up to 600V and is rated 420A at 75°C. It's used for 400A feeders in a single run, 800A and 1200A services in parallel sets, and main switchboard feeds.

What are the main differences between XHHW and XHHW-2 wires?

Both use cross-linked polyethylene (XLPE) insulation and are rated 600V. The difference is the wet rating. XHHW is rated 90°C in dry locations but only 75°C in wet locations. XHHW-2 is rated 90°C in both, and it passes stricter UL 44 moisture testing. XHHW-2 can be used anywhere XHHW is allowed.

What is the difference between THHN and XHHW-2 wire?

Both THHN/THWN-2 and XHHW-2 are 600V building wires rated 90°C in wet and dry locations, so the real difference is the insulation. THHN/THWN-2 has thin PVC insulation with a nylon jacket. XHHW-2 has a single, thicker layer of cross-linked polyethylene (XLPE), a thermoset material that doesn't melt. XHHW-2 holds up better to abrasion, moisture, and cold. THHN/THWN-2 has a smaller diameter, so more conductors fit in the same conduit, and it usually costs less.

Can XHHW-2 wire be buried underground?

Not directly. XHHW-2 is not rated for direct burial, so it can't go in a trench without conduit. It can be installed underground inside conduit, because underground raceways are wet locations and XHHW-2 is rated 90°C wet. For burial without conduit, use a direct burial cable such as USE-2 or URD.

Does XHHW-2 wire have to be run in conduit?

Yes, in standard building installations. XHHW-2 is a single-conductor building wire meant for conduit or other recognized raceways. It can't be run exposed outdoors or fished through walls like NM cable, so inside a wall it has to be in conduit, such as EMT or flexible metal conduit. The NEC allows a few exceptions, such as cable tray for 1/0 AWG and larger conductors with a CT marking, or open wiring on insulators, but these are uncommon.

Is XHHW-2 wire sunlight resistant?

Yes. NNC's XHHW-2 is marked sunlight resistant, so it holds up in conduit runs exposed to the sun and where the wire leaves the conduit, such as at a weatherhead. Sunlight resistance doesn't replace the conduit requirement.

Can XHHW-2 wire be used in cold weather?

Yes. XLPE insulation stays flexible in the cold much better than PVC-insulated THHN, which makes XHHW-2 easier to pull in winter. It's commonly rated for installation down to -40°C (-40°F). Check the spec sheet for the exact minimum.

Is 600 MCM copper XHHW-2 used in data centers?

Yes. 600 MCM copper XHHW-2 runs in two parallel sets for 800A switchboard and UPS feeders, and in three sets for an 800 kVA, 480V UPS (1203A at 125%).

Reviews
Get in Touch
Live Chat Get replies right away!
Email info@nassaunationalcable.com

Call Us: 1-516-482-6313    Text Us: 1-516-703-3460