3/0 AWG XHHW-2 Stranded Copper Building Wire
Where are we? 4 Continents 9 Countries

Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Quick Support
3/0 AWG XHHW-2 Stranded Copper Building Wire
Applications:
3/0 AWG copper XHHW-2 is installed in conduit and other NEC-recognized raceways for services, feeders, and branch circuits, in wet or dry locations at up to 600V. It's rated 200A at 75°C and 225A at 90°C. Typical uses:
-
200A services and feeders at full rating in commercial and other non-dwelling installations
-
225A home services under NEC 310.12
-
400A services run as two parallel sets
-
200A generator feeders and transfer switches
Also Known As:
3/0 XHHW-2 Copper Building Wire, 3/0 XHHW Cable, 3/0 XHHW Service Wire, 3/0 XHHW Copper Wire, 3/0 CU Building Wire, 3/0 Black Stranded CU SIMpull XHHW-2 Wire, Southwire 11302799, Southwire Wire, 3/0 AWG XHHW Building Wire, 3/0 XHHW Building Wire, 3/0 Gauge Black Stranded Copper XHHW-2 Wire, 3/0 Stranded Copper XHHW-2 Wire, 200 amp wire, 200 amp cable.
Construction:
Conductor:
Class B compressed stranded bare copper per ASTM B3 and ASTM B8
Insulation:
Cross Linked Polyethylene (XLPE) with SIMpull Technology. Silicone-Free, Abrasion, High-Heat, Moisture Resistant.
Features:
- SIS- 8 AWG
- Sunlight resistant
- -40°C Cold bend
- FT1
- Gasoline and Oil Resistant II
- CT Rated- 1/0 AWG and larger
- FT4- 350 kcmil and larger
- RoHS/REACH Compliant
Standards:
- ASTM B3 Soft or Annealed Copper Wire
- ASTM B8 Concentric-Lay-Stranded Copper Conductors
- ASTM B787 19 Wire Combination Unilay-Stranded Copper Conductors
- UL 44 Thermoset-Insulated Wires and Cables
- UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger)
- CSA C22.2 No. 38 Thermoset-insulated wires and cables
- ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
- IEEE 1202/FT4 Flame Test (70,000 BTU/hr) 350kcmil and Larger
- Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661
- Federal Specification A-A-59544
- NMX-J-451-ANCE Thermoset insulated wires and cables
- NOM-063-SCFI Electrical Products – Conductors – Safety Requirements
Specifications:
- Size : 3/0 AWG
- Number of Strands: 19
- Diameter Over Conductor ( Inch ): 0.456
- Insulation Thickness (mils): 55
-
Aprox. OD (inches): 0.574
-
Copper Weight ( lbs/mft ): 518 lbs
- Net Weight ( lbs/mft ): 564 lbs
- Min Bending Radius: 2.3 inch
- Max Pull Tension: 1342 lbs
- Allowable Ampacity At 60°C: 165 Amp
- Allowable Ampacity At 75°C: 200 Amp
- Allowable Ampacity At 90°C: 225 Amp
-
Southwire Part ( SimPull): 11302799
|
Compatible with Manufacturer |
|
|
Advanced Digital : |
2030CT |
|
Omni Cable : |
Black : M73/0ST-01 |
|
Southwire : |
Black : 11302799 |
|
HWC : |
HW00230101 |
|
Priority Wire & Cable : |
3/0STRXHHW |
|
Service Wire Co : |
XH3/0BK |
FAQ's
What is 3/0 copper XHHW-2 used for?
What are the main differences between XHHW and XHHW-2 wires?
What is the difference between THHN and XHHW-2 wire?
Is 3/0 copper XHHW-2 rated for a 200 amp service?
Can XHHW-2 wire be buried underground?
Does XHHW-2 wire have to be run in conduit?
Is XHHW-2 wire sunlight resistant?
Can XHHW-2 wire be used in cold weather?
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460