3/0 AWG XHHW-2 Stranded Copper Building Wire
nassaunationalcable.com/en-ca/products/3-0-awg-xhhw-2-stranded-copper-building-wire
Items in Cart ()
View cart

3/0 AWG XHHW-2 Stranded Copper Building Wire

750 MCM XHHW-2 COPPER BUILDING WIRE
Roll over image to Zoom
3/0 AWG XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
3/0 AWG XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
3/0 AWG XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
3/0 AWG XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
3/0 AWG XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
3/0 AWG XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
3/0 AWG XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
3/0 AWG XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
3/0 AWG XHHW-2 Stranded Copper Building Wire
SKU: NNC2453X
xhhw-2-copper-building-wire-conductor

Availability: In stock

Price:
Regular price
$7.29 /FT
Sale price
$7.29 /FT
Shipping Cost Calculated at Checkout. Standard Lead Time is 1 to 6 Business Days.
Free Shipping: On orders above $1000
Quantity must be 1 or more

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

Based on 2 reviews
100%
(2)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
J
Jason Tiger
Great stuff, and nice color options!

Can't find this stuff in my town, and obviously not an option in my big box stores. The color variety was nice to pick from, too! Shipping was on time and great packaging and measurements.

P
Paul Ulman
Great Wire and Fast Shipping

Shipping was fast and wire arrived in good packaging. It had length marking so it was easy to verify the length. Double and Triple check the length you need before you order.

Where are we? 4 Continents 9 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Product Information
Specification

3/0 AWG XHHW-2 Stranded Copper Building Wire

Applications:

3/0 AWG copper XHHW-2 is installed in conduit and other NEC-recognized raceways for services, feeders, and branch circuits, in wet or dry locations at up to 600V. It's rated 200A at 75°C and 225A at 90°C. Typical uses:

  • 200A services and feeders at full rating in commercial and other non-dwelling installations

  • 225A home services under NEC 310.12

  • 400A services run as two parallel sets

  • 200A generator feeders and transfer switches

Also Known As: 

3/0 XHHW-2 Copper Building Wire, 3/0 XHHW Cable, 3/0 XHHW Service Wire, 3/0 XHHW Copper Wire, 3/0 CU Building Wire, 3/0 Black Stranded CU SIMpull XHHW-2 Wire, Southwire 11302799, Southwire Wire, 3/0 AWG XHHW Building Wire, 3/0 XHHW Building Wire, 3/0 Gauge Black Stranded Copper XHHW-2 Wire, 3/0 Stranded Copper XHHW-2 Wire, 200 amp wire, 200 amp cable.

    Construction:

    Conductor: 

    Class B compressed stranded bare copper per ASTM B3 and ASTM B8

    Insulation:

    Cross Linked Polyethylene (XLPE) with SIMpull Technology. Silicone-Free, Abrasion, High-Heat, Moisture Resistant.

    Features:

    • SIS- 8 AWG
    • Sunlight resistant
    • -40°C Cold bend
    • FT1
    • Gasoline and Oil Resistant II
    • CT Rated- 1/0 AWG and larger
    • FT4- 350 kcmil and larger
    • RoHS/REACH Compliant

    Standards:

    • ASTM B3 Soft or Annealed Copper Wire
    • ASTM B8 Concentric-Lay-Stranded Copper Conductors
    • ASTM B787 19 Wire Combination Unilay-Stranded Copper Conductors
    • UL 44 Thermoset-Insulated Wires and Cables
    • UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger)
    • CSA C22.2 No. 38 Thermoset-insulated wires and cables
    • ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
    • IEEE 1202/FT4 Flame Test (70,000 BTU/hr) 350kcmil and Larger
    • Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661
    • Federal Specification A-A-59544
    • NMX-J-451-ANCE Thermoset insulated wires and cables
    • NOM-063-SCFI Electrical Products – Conductors – Safety Requirements

    Specifications:

    • Size : 3/0 AWG
    • Number of  Strands: 19
    • Diameter Over Conductor ( Inch ): 0.456
    • Insulation Thickness (mils): 55
    • Aprox. OD (inches): 0.574
    • Copper Weight ( lbs/mft ): 518 lbs
    • Net Weight  ( lbs/mft ): 564 lbs
    • Min Bending Radius: 2.3 inch
    • Max Pull Tension: 1342 lbs
    • Allowable Ampacity At 60°C: 165 Amp
    • Allowable Ampacity At 75°C: 200 Amp
    • Allowable Ampacity At 90°C: 225 Amp
    • Southwire Part ( SimPull): 11302799

    Compatible with Manufacturer

    Advanced Digital : 

    2030CT

    Omni Cable :

    Black : M73/0ST-01
    White : M73/0ST-02
    Red : M73/0ST-03
    Green : M73/0ST-04
    Blue : M73/0ST-05
    Gray : M73/0ST-06
    Orange : M73/0ST-07
    Yellow : M73/0ST-08
    Purple : M73/0ST-09
    Brown : M73/0ST-10
    Pink : M73/0ST-11
    Tan : M73/0ST-12

    Southwire :

    Black : 11302799
    White : 55388099
    Red : 55388199
    Blue : 55388299
    Green : 55388499

    Yellow : 55388799
    Orange : 55388699
    Brown : 55388599
    Gray : 55388899

    HWC : 

    HW00230101

    Priority Wire & Cable : 

    3/0STRXHHW

    Service Wire Co : 

    XH3/0BK


    *Data provided on this page is subject to change based on different manufacturers' variances
    ** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
    In the case the material only comes in a predetermined color or doesn’t come with any color
    Download PDF Spec Sheet

    FAQ's

    What is 3/0 copper XHHW-2 used for?

    XHHW-2 is single-conductor building wire with cross-linked polyethylene (XLPE) insulation, which is where the "X" in its name comes from. "HHW" stands for high heat and water resistance, and "-2" means it's rated 90°C in wet locations as well as dry. 3/0 AWG copper XHHW-2 is installed in conduit or other NEC-recognized raceways at up to 600V and is rated 200A at 75°C. It's used for 200A commercial services and feeders at full rating, 225A home services, and 400A services in two parallel sets.

    What are the main differences between XHHW and XHHW-2 wires?

    Both use cross-linked polyethylene (XLPE) insulation and are rated 600V. The difference is the wet rating. XHHW is rated 90°C in dry locations but only 75°C in wet locations. XHHW-2 is rated 90°C in both, and it passes stricter UL 44 moisture testing. XHHW-2 can be used anywhere XHHW is allowed.

    What is the difference between THHN and XHHW-2 wire?

    Both THHN/THWN-2 and XHHW-2 are 600V building wires rated 90°C in wet and dry locations, so the real difference is the insulation. THHN/THWN-2 has thin PVC insulation with a nylon jacket. XHHW-2 has a single, thicker layer of cross-linked polyethylene (XLPE), a thermoset material that doesn't melt. XHHW-2 holds up better to abrasion, moisture, and cold. THHN/THWN-2 has a smaller diameter, so more conductors fit in the same conduit, and it usually costs less.

    Is 3/0 copper XHHW-2 rated for a 200 amp service?

    Yes, in any application. 3/0 copper is rated 200A at 75°C, which covers a full 200A load in commercial and other non-dwelling installations. For a 200A home service, 2/0 copper is enough under NEC 310.12.

    Can XHHW-2 wire be buried underground?

    Not directly. XHHW-2 is not rated for direct burial, so it can't go in a trench without conduit. It can be installed underground inside conduit, because underground raceways are wet locations and XHHW-2 is rated 90°C wet. For burial without conduit, use a direct burial cable such as USE-2 or URD.

    Does XHHW-2 wire have to be run in conduit?

    Yes, in standard building installations. XHHW-2 is a single-conductor building wire meant for conduit or other recognized raceways. It can't be run exposed outdoors or fished through walls like NM cable, so inside a wall it has to be in conduit, such as EMT or flexible metal conduit. The NEC allows a few exceptions, such as cable tray for 1/0 AWG and larger conductors with a CT marking, or open wiring on insulators, but these are uncommon.

    Is XHHW-2 wire sunlight resistant?

    Yes. NNC's XHHW-2 is marked sunlight resistant, so it holds up in conduit runs exposed to the sun and where the wire leaves the conduit, such as at a weatherhead. Sunlight resistance doesn't replace the conduit requirement.

    Can XHHW-2 wire be used in cold weather?

    Yes. XLPE insulation stays flexible in the cold much better than PVC-insulated THHN, which makes XHHW-2 easier to pull in winter. It's commonly rated for installation down to -40°C (-40°F). Check the spec sheet for the exact minimum.

    Reviews

    Customer Reviews

    Based on 2 reviews
    100%
    (2)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    J
    Jason Tiger
    Great stuff, and nice color options!

    Can't find this stuff in my town, and obviously not an option in my big box stores. The color variety was nice to pick from, too! Shipping was on time and great packaging and measurements.

    P
    Paul Ulman
    Great Wire and Fast Shipping

    Shipping was fast and wire arrived in good packaging. It had length marking so it was easy to verify the length. Double and Triple check the length you need before you order.

    Get in Touch
    Live Chat Get replies right away!
    Email info@nassaunationalcable.com

    Call Us: 1-516-482-6313    Text Us: 1-516-703-3460