300 MCM XHHW-2 Stranded Copper Building Wire
nassaunationalcable.com/en-ca/products/300-mcm-xhhw-2-stranded-copper-building-wire
Items in Cart ()
View cart

300 MCM XHHW-2 Stranded Copper Building Wire

750 MCM XHHW-2 COPPER BUILDING WIRE
Roll over image to Zoom
300 MCM XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
300 MCM XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
300 MCM XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
300 MCM XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
300 MCM XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
300 MCM XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
300 MCM XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
300 MCM XHHW-2 Stranded Copper Building Wire
Roll over image to Zoom
300 MCM XHHW-2 Stranded Copper Building Wire
SKU: NNC2489X
xhhw-2-copper-building-wire-conductor

Availability: In stock

Price:
Regular price
$12.89 /FT
Sale price
$12.89 /FT
Shipping Cost Calculated at Checkout. Standard Lead Time is 1 to 6 Business Days.
Free Shipping: On orders above $1000
Quantity must be 1 or more

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

Based on 1 review
100%
(1)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
K
Kathleen Lusk
Definitely purchase again

Easy to use website and speedy shipping

Where are we? 4 Continents 9 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Product Information
Specification

300 MCM XHHW-2 Stranded Copper Building Wire

Applications:

300 MCM copper XHHW-2 is installed in conduit and other NEC-recognized raceways for services, feeders, and branch circuits, in wet or dry locations at up to 600V. It's rated 285A at 75°C and 320A at 90°C. Typical uses:

  • 250A feeders with headroom for derating

  • 500A services run as two parallel sets

  • 800A services run as three parallel sets

  • Feeders to chillers and large rooftop units

Also Known As: 

300 MCM Wire, 300 KCMIL Wire, 300 XHHW Cable 37 Strand, 300 KCMIL CU Cable, 300 MCM Copper Cable, 300 KCMIL CU Cable, 300 XHHW-2 Copper Building Wire, 300 XHHW Cable, 300 XHHW Service Wire, 300 XHHW-2 Copper Wire, 300 CU Building Wire, 300 Black Stranded CU SIMpull XHHW-2 Wire, Southwire 11305099, Southwire Wire, 300 MCM XHHW Building Wire, XHHW Stranded Building Wire.

300 MCM XHHW-2 Copper Data Center Applications

In data centers, 300 MCM copper XHHW-2 is used for feeders between switchgear, UPS systems, PDUs, and panels. Data center loads run continuously, so NEC 215.2 sizes feeders at 125% of the load unless the breaker is 100% rated.

  • Single-run feeders for 225A continuous loads (281A at 125%)

  • Three parallel sets for 800A switchboards

  • Feeders to chillers and cooling plant equipment

    Construction:

    Conductor: 

    Class B compressed stranded bare copper per ASTM B3 and ASTM B8

    Insulation:

    Cross Linked Polyethylene (XLPE) with SIMpull Technology. Silicone-Free, Abrasion, High-Heat, Moisture Resistant.

    Features:

    • SIS- 8 AWG
    • Sunlight resistant
    • -40°C Cold bend
    • FT1
    • Gasoline and Oil Resistant II
    • CT Rated- 1/0 AWG and larger
    • FT4- 350 kcmil and larger
    • RoHS/REACH Compliant

    Standards:

    • ASTM B3 Soft or Annealed Copper Wire
    • ASTM B8 Concentric-Lay-Stranded Copper Conductors
    • ASTM B787 19 Wire Combination Unilay-Stranded Copper Conductors
    • UL 44 Thermoset-Insulated Wires and Cables
    • UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger)
    • CSA C22.2 No. 38 Thermoset-insulated wires and cables
    • ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
    • IEEE 1202/FT4 Flame Test (70,000 BTU/hr) 350kcmil and Larger
    • Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661
    • Federal Specification A-A-59544
    • NMX-J-451-ANCE Thermoset insulated wires and cables
    • NOM-063-SCFI Electrical Products – Conductors – Safety Requirements

    Specifications:

    • Size : 300 MCM
    • Number of  Strands: 37
    • Diameter Over Conductor ( Inch ): 0.610
    • Insulation Thickness (mils): 65
    • Aprox. OD (inches): 0.753
    • Copper Weight ( lbs/mft ): 926 lbs
    • Net Weight  ( lbs/mft ): 998 lbs
    • Min Bending Radius: 3 inch
    • Max Pull Tension: 2400 lbs
    • Allowable Ampacity At 60°C: 240 Amp
    • Allowable Ampacity At 75°C: 285 Amp
    • Allowable Ampacity At 90°C: 320 Amp
    • Southwire Part ( SimPull): 11305099

    Compatible with Manufacturer

    Advanced Digital : 

    20300CT

    Omni Cable :

    Black : M7300ST-01
    White : M7300ST-02
    Red : M7300ST-03
    Green : M7300ST-04
    Blue : M7300ST-05
    Gray : M7300ST-06
    Orange : M7300ST-07
    Yellow : M7300ST-08
    Purple : M7300ST-09
    Brown : M7300ST-10
    Pink : M7300ST-11
    Tan : M7300ST-12

    Southwire :

    Black : 11305099
    White : 64385098
    Red : 64384849
    Blue : 64384998
    Green : 58012199

    Yellow : 56113199
    Orange : 56113099
    Brown : 56112999
    Gray : 58403999

    HWC : 

    HW00230001

    Service Wire Co : 

    XH300BK


    *Data provided on this page is subject to change based on different manufacturers' variances
    ** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
    In the case the material only comes in a predetermined color or doesn’t come with any color
    Download PDF Spec Sheet

    FAQ's

    What is 300 MCM copper XHHW-2 used for?

    XHHW-2 is single-conductor building wire with cross-linked polyethylene (XLPE) insulation, which is where the "X" in its name comes from. "HHW" stands for high heat and water resistance, and "-2" means it's rated 90°C in wet locations as well as dry. 300 MCM copper XHHW-2 is installed in conduit or other NEC-recognized raceways at up to 600V and is rated 285A at 75°C. It's used for 250A feeders with headroom for derating, 500A and 800A services in parallel sets, and chiller feeders.

    What are the main differences between XHHW and XHHW-2 wires?

    Both use cross-linked polyethylene (XLPE) insulation and are rated 600V. The difference is the wet rating. XHHW is rated 90°C in dry locations but only 75°C in wet locations. XHHW-2 is rated 90°C in both, and it passes stricter UL 44 moisture testing. XHHW-2 can be used anywhere XHHW is allowed.

    What is the difference between THHN and XHHW-2 wire?

    Both THHN/THWN-2 and XHHW-2 are 600V building wires rated 90°C in wet and dry locations, so the real difference is the insulation. THHN/THWN-2 has thin PVC insulation with a nylon jacket. XHHW-2 has a single, thicker layer of cross-linked polyethylene (XLPE), a thermoset material that doesn't melt. XHHW-2 holds up better to abrasion, moisture, and cold. THHN/THWN-2 has a smaller diameter, so more conductors fit in the same conduit, and it usually costs less.

    Can XHHW-2 wire be buried underground?

    Not directly. XHHW-2 is not rated for direct burial, so it can't go in a trench without conduit. It can be installed underground inside conduit, because underground raceways are wet locations and XHHW-2 is rated 90°C wet. For burial without conduit, use a direct burial cable such as USE-2 or URD.

    Does XHHW-2 wire have to be run in conduit?

    Yes, in standard building installations. XHHW-2 is a single-conductor building wire meant for conduit or other recognized raceways. It can't be run exposed outdoors or fished through walls like NM cable, so inside a wall it has to be in conduit, such as EMT or flexible metal conduit. The NEC allows a few exceptions, such as cable tray for 1/0 AWG and larger conductors with a CT marking, or open wiring on insulators, but these are uncommon.

    Is XHHW-2 wire sunlight resistant?

    Yes. NNC's XHHW-2 is marked sunlight resistant, so it holds up in conduit runs exposed to the sun and where the wire leaves the conduit, such as at a weatherhead. Sunlight resistance doesn't replace the conduit requirement.

    Can XHHW-2 wire be used in cold weather?

    Yes. XLPE insulation stays flexible in the cold much better than PVC-insulated THHN, which makes XHHW-2 easier to pull in winter. It's commonly rated for installation down to -40°C (-40°F). Check the spec sheet for the exact minimum.

    Is 300 MCM copper XHHW-2 used in data centers?

    Yes. 300 MCM copper XHHW-2 feeds 225A continuous loads in a single run (281A at 125%) and 800A switchboards in three parallel sets. It's also used for chiller and cooling plant feeders.

    Reviews

    Customer Reviews

    Based on 1 review
    100%
    (1)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    K
    Kathleen Lusk
    Definitely purchase again

    Easy to use website and speedy shipping

    Get in Touch
    Live Chat Get replies right away!
    Email info@nassaunationalcable.com

    Call Us: 1-516-482-6313    Text Us: 1-516-703-3460