1 Quad 1.0 mm² JIS C 3410 250V FR-RCOP(OS) Shipboard Fire Resistant Instrumentation Cable
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
1 Quad 1.0 mm² JIS C 3410 250V FR-RCOP(OS) Shipboard Fire Resistant Instrumentation Cable
Allowable Ampacity For 1 Quad 1.0 mm² JIS C 3410 250V RCOP(OS) Shipboard Flame Retardant Instrumentation Cable: 100 Amps
Application Standard :
- • Design guide: IEC 60092-350 & IEC60092-376
- • Insulationmaterial: IEC 60092-351,EPR
- • Sheathmaterial: IEC 60092-359, SE1 &ST2
- • Flame-retardant : IEC 60332-1 & IEC 60332-3 Category A
- • Fireresistant: IEC 60331-21 & IEC 60331-1 or-2 (120minute)
- • Max. rated conductor temperature: 90℃
Also Known As :
Shipboard Cable, JIS C 3410 250V FR-RCOP(OS), Stranded Tinned Annealed Copper Wires, Flame-Retardant Instrumentation Cable, Braid Of Plain Annealed Copper Wires, Twisted Pairs
Construction :
Conductor :
- • Stranded Tinned Annealed Copper Wires As Per IEC 60228, Class2
- • A Suitable Tape May Be Applied On The Conductor
Fire Resisting Layer :
- • Code: FR
- • Mica/Glasstape
Insulation :
- • Code: R
- • EPR As Per IEC60092-351
Twisting :
- • Two/Three Insulated Cores Shall Be Twisted Together To Form A Pair/Triad
Cabling :
- • Twisted Pairs/Triads Shall Be Cabled
- • Flame Retardant & Non-Hygroscopic Fillers May Be Used
- • Suitable Tape(s) May Be Applied On The Cabled Core
Collective Screen :
- • Code: (OS)
- • AL/PS Tape + Tinned Copper Drain Wire
- • A Suitable Tape May Be Applied On The Collective Screen
Inner Sheath :
- • Code: C
- • SE1 As Per IEC60092-359
Armour :
- • Code: O
- • Braid Of Plain Annealed Copper Wires
- • A Suitable Separator Tape(s) May Be Applied Under/Over The Armour
Outer Sheath :
- • Code: P
- • ST2 (PVC) as per IEC60092-359
Core Identification :
- • Printed Pair/Triad Number And Alphabet Letter On The White Insulation
- • ex) 4P : (1A, 1B), (2A, 2B), (3A, 3B), (4A,4B)
- • 2T : (1A, 1B, 1C), (2A, 2B,2C)
Specification :
- • No. of Quad: 1Q
- • Conductor Nominal Area: 1.0 mm²
- • Conductor Strand : 7 / 0.43 No./mm
- • Conductor Dia. : 1.29 mm
- • Nominal Dia.Inner Sheath: 10.4 mm
- • Overall Diameter Nominal: 14.2 mm
- • Overall Diameter Tolerance: 0.9 ±mm
- • Conductor Resistance (at 20°C)(Max) : 19.3 Ω/km
- • Insulation Resistance (at 20°C)(Min) : 20 ㏁-km
- • Cable Weight (Approx.) : 0.2328 Lbs
*Data provided on this page is subject to change based on different manufacturers' variances