HVTECK Aluminum 3/C 115 mil NLEPR TS AIA 5kV 133% IL Orange PVC Jacket CSA
Select a Gauge
Where are we? 4 Continents 9 Countries

Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Quick Support
HVTECK Aluminum 3/C 115 mil NLEPR TS AIA 5kV 133% IL Orange PVC Jacket CSA
Application:
The 5kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs /FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant. 3 Conductor, 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR), 133% Insulation Level, Tape Shield, Polyvinyl Chloride (PVC) Inner Jacket, Aluminum Interlocked Armour (AIA), Polyvinyl Chloride (PVC) Jacket.
Also Known as:
5kV HVTECK Cable, 5kV HVTECK Armoured Cable, 5kV CSA Armoured Cable, 5kV Medium Voltage Cable, 5kV MV Power Cable, 5kV Shielded Power Cable, 5kV 3/C Aluminum Cable, 3/C Aluminum Medium Voltage Cable, Aluminum Armoured MV Cable, Aluminum Interlocked Armour Cable, AIA Armoured Cable, 5kV AIA Cable, NL-EPR Insulated Cable, 115 mil EPR Cable,133% Insulation Level Cable, Copper Tape Shielded Cable, PVC Jacketed Armoured Cable, Orange PVC Jacket Cable, CSA HVTECK Cable
Construction:
Conductor: Class B compact stranded 8000 Series aluminum per ASTM B800 and ASTM
B836
Conductor Shield: Semi-conducting cross-linked copolymer; A conductor separator is used for cable size larger than or equal to 500 Kcmil
Insulation: 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% insulation level
Insulation Shield: Strippable semi-conducting cross-linked copolymer
Copper Tape Shield: Helically wrapped 5 mil copper tape with 25% overlap
Filler: Interstices filled with non-hydroscoping/non-wicking fillers
Grounding Conductor: Class B compressed stranded bare copper ground per ASTM B3 and ASTM B8
Binder: Polypropylene tape
Inner Jacket: PVC inner jacket
Armour: Aluminum Interlocked Armour (AIA)
Overall Jacket: Orange Polyvinyl Chloride (PVC) Jacket.
Standards:
ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy
ASTM B836 Compact Rounded Stranded Aluminum Conductors
CSA C22.2 No. 174 Cables in Hazardous Locations
CSA C22.2 No. 2556 & No. 0.3 Wire and Cable Test Methods
CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV
CSA C68.3 Shielded & Concentric Neutral Power Cable - 5 to 46 kV
CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating
CSA HL - for Hazardous Locations rating
CSA SUN RES - for Sunlight Resistant rating
ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
ICEA T-29-520 Flame Test (210,000 BTU/Hr)
IEEE 383 Flame Test (70,000 btu)
IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
FT1 Flame Test (1,706 BTU/Hr nominal - Vertical Wire Flame Test)
AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements).