350 MCM 3C HVTECK Aluminum 115 mil NLEPR TS AIA 5kV 133% IL Orange PVC Jacket CSA
Where are we? 4 Continents 9 Countries

Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Quick Support
350 MCM 3C HVTECK Aluminum 115 mil NLEPR TS AIA 5kV 133% IL Orange PVC Jacket CSA
Application:
The 5kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs /FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant. 3 Conductor, 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR), 133% Insulation Level, Tape Shield, Polyvinyl Chloride (PVC) Inner Jacket, Aluminum Interlocked Armour (AIA), Polyvinyl Chloride (PVC) Jacket.
Also known as :
350 MNM 3C 5kV HVTECK Cable, 350 MNM 3C 5kV HVTECK Armoured Cable, 350 MNM 3C 5kV CSA Armoured Cable, 350 MNM 3C 5kV Medium Voltage Cable, 350 MNM 3C 5kV MV Power Cable, 350 MNM 3C 5kV Shielded Power Cable, 350 MNM 3C 5kV 3/C Aluminum Cable, 350 MNM 3C 3/C Aluminum Medium Voltage Cable, 350-3C Aluminum Armoured MV Cable, 350-3C Aluminum Interlocked Armour Cable, 350-3C AIA Armoured Cable, 350-3C 5kV AIA Cable, 350-3C NL-EPR Insulated Cable, 350-3C 115 mil EPR Cable, 350-3C 133% Insulation Level Cable, 350-3C Copper Tape Shielded Cable, 350-3C PVC Jacketed Armoured Cable, 350-3C Orange PVC Jacket Cable, 350-3C CSA HVTECK Cable.
Construction:
Conductor: Class B compact stranded 8000 Series aluminum per ASTM B800 and ASTM B836
Conductor Shield: Semi-conducting cross-linked copolymer; A conductor separator is used for cable size larger than or equal to 500 Kcmil
Insulation: 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% insulation level
Insulation Shield: Strippable semi-conducting cross-linked copolymer
Copper Tape Shield: Helically wrapped 5 mil copper tape with 25% overlap
Filler: Interstices filled with non-hydroscoping/non-wicking fillers
Grounding Conductor: Class B compressed stranded bare copper ground per ASTM B3 and ASTM B8
Binder: Polypropylene tape
Inner Jacket: PVC inner jacket
Armour: Aluminum Interlocked Armour (AIA)
Overall Jacket: Orange Polyvinyl Chloride (PVC) Jacket
Standards:
ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy
ASTM B836 Compact Rounded Stranded Aluminum Conductors
CSA C22.2 No. 174 Cables in Hazardous Locations
CSA C22.2 No. 2556 & No. 0.3 Wire and Cable Test Methods
CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV
CSA C68.3 Shielded & Concentric Neutral Power Cable - 5 to 46 kV
CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating
CSA HL - for Hazardous Locations rating
CSA SUN RES - for Sunlight Resistant rating
ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
ICEA T-29-520 Flame Test (210,000 BTU/Hr)
IEEE 383 Flame Test (70,000 btu)
IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
FT1 Flame Test (1,706 BTU/Hr nominal - Vertical Wire Flame Test)
AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)
Specification:
Conductor size: 350 AWG
Strand: 37
Diameter Over Conductor: 0.615inch
Diameter Over Insulation: 0.891inch
Insulation Thickness: 115mil
Diameter Over Insulation Shield: 0.951inch
Ground Size: 4AWG
Inner Jacket Thickness: 110mil
Diameter. Over Armour: 2.673inch
Overall Jacket Thickness: 75mil
Approx.OD: 2.823inch
Approx. Weight(lb/1000ft): 3419
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460