3/0 AWG 3C HVTECK Aluminum 115 mil NLEPR TS AIA 5kV 133% IL Orange PVC
nassaunationalcable.com/en-ca/products/3-0-awg-3c-hvteck-aluminum-115-mil-nlepr-ts-aia-5kv-133-il-orange-pvc-jacket-csa
Items in Cart ()
View cart

3/0 AWG 3C HVTECK Aluminum 115 mil NLEPR TS AIA 5kV 133% IL Orange PVC Jacket CSA

3/0 AWG 3C HVTECK Aluminum 115 mil NLEPR TS AIA 5kV 133% IL Orange PVC Jacket CSA
Roll over image to Zoom
3/0 AWG 3C HVTECK Aluminum 115 mil NLEPR TS AIA 5kV 133% IL Orange PVC Jacket CSA
SKU: NNC9635
hvteck-aluminum-3-c-115-mil-nlepr-ts-aia-5kv-133-il-orange-pvc-jacket-csa
Min Length: 1 FT
Max Length: 10000 FT
Price:
Regular price
$0.00 /FT
Sale price
$0.00 /FT
Shipping Cost Calculated at Checkout. Standard Lead Time is 1 to 6 Business Days.
Free Shipping: On orders above $1000
Quantity must be 1 or more

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Where are we? 4 Continents 9 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Product Information
Specification

3/0 AWG 3C HVTECK Aluminum 115 mil NLEPR TS AIA 5kV 133% IL Orange PVC Jacket CSA

Application:

The  5kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs /FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant. 3 Conductor, 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR), 133% Insulation Level, Tape Shield, Polyvinyl Chloride (PVC) Inner Jacket, Aluminum Interlocked Armour (AIA), Polyvinyl Chloride (PVC) Jacket.

Also known as :

3/0 AWG 3C 5kV HVTECK Cable,3/0 AWG 3C 5kV HVTECK Armoured Cable,3/0AWG 3C 5kV CSA Armoured Cable, 3/0 AWG 3C 5kV Medium Voltage Cable,3/0 AWG 3C 5kV MV Power Cable,3/0 AWG 3C 5kV Shielded Power Cable,3/0 AWG 3C  5kV 3/C Aluminum Cable, 3/0 AWG 3C 3/C Aluminum Medium Voltage Cable,3/0-3C Aluminum Armoured MV Cable,3/0-3C Aluminum Interlocked Armour Cable,3/0-3C AIA Armoured Cable, 3/0-3C 5kV AIA Cable, 3/0-3C NL-EPR Insulated Cable,3/0-3C 115 mil EPR Cable,3/0-3C 133% Insulation Level Cable, 3/0-3C Copper Tape Shielded Cable, 3/0-3C PVC Jacketed Armoured Cable,3/0-3C Orange PVC Jacket Cable,3/0-3C CSA HVTECK Cable.

Construction:

Conductor: Class B compact stranded 8000 Series aluminum per ASTM B800 and ASTM B836
Conductor Shield: Semi-conducting cross-linked copolymer; A conductor separator is used for cable size larger than or equal to 500 Kcmil
Insulation: 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% insulation level
Insulation Shield: Strippable semi-conducting cross-linked copolymer
Copper Tape Shield: Helically wrapped 5 mil copper tape with 25% overlap
Filler: Interstices filled with non-hydroscoping/non-wicking fillers
Grounding Conductor: Class B compressed stranded bare copper ground per ASTM B3 and ASTM B8
Binder: Polypropylene tape
Inner Jacket: PVC inner jacket
Armour: Aluminum Interlocked Armour (AIA)
Overall Jacket: Orange Polyvinyl Chloride (PVC) Jacket

Standards:

 ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy
 ASTM B836 Compact Rounded Stranded Aluminum Conductors
 CSA C22.2 No. 174 Cables in Hazardous Locations
 CSA C22.2 No. 2556 & No. 0.3 Wire and Cable Test Methods
 CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV
 CSA C68.3 Shielded & Concentric Neutral Power Cable - 5 to 46 kV
 CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating
 CSA HL - for Hazardous Locations rating
 CSA SUN RES - for Sunlight Resistant rating
 ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
 ICEA T-29-520 Flame Test (210,000 BTU/Hr)
 IEEE 383 Flame Test (70,000 btu)
 IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
 FT1 Flame Test (1,706 BTU/Hr nominal - Vertical Wire Flame Test)
 AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through  46KV (Qualification Test Requirements)

SPECIFICATIONS:

Conductor size:  3/0AWG
Strand: 19
Diameter Over Conductor: 0.422inch
Diameter Over Insulation:  0.690inch
Insulation Thickness: 115mil
Diameter Over Insulation Shield:  0.750inch
Ground Size:  6AWG
Inner Jacket Thickness: 110mil
Diameter. Over Armour:2.239inch
Overall Jacket Thickness: 60mil
Approx.OD: 2.359inch
Approx. Weight(lb/1000ft): 2284


*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet

Reviews

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Get in Touch
Live Chat Get replies right away!
Email info@nassaunationalcable.com

Call Us: 1-516-482-6313    Text Us: 1-516-703-3460