300-300-300-4/0 ALUMINUM SER CABLE
nassaunationalcable.com/en-ca/products/300-300-300-4-0-aluminum-ser-cable
Items in Cart ()
View cart

300-300-300-4/0 ALUMINUM SER CABLE

300-300-300-4/0 ALUMINUM SER CABLE
Roll over image to Zoom
300-300-300-4/0 ALUMINUM SER CABLE
Roll over image to Zoom
300-300-300-4/0 ALUMINUM SER CABLE
SKU: NNC1706X11
aluminum-ser-service-entrance-type-r-cable

Availability: In stock

Min Length: 1 FT
Max Length: 10000 FT
Price:
Regular price
$7.28 /FT
Sale price
$7.28 /FT
Shipping Cost Calculated at Checkout. Standard Lead Time is 1 to 6 Business Days.
Free Shipping: On orders above $1000
Quantity must be 1 or more

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Where are we? 4 Continents 9 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Product Information
Specification

300-300-300-4/0 ALUMINUM SER CABLE

Allowable Ampacity for 300-300-300-4/0 ALUMINUM SER CABLE at 60°C: 195 Amps

Allowable Ampacity for 300-300-300-4/0 ALUMINUM SER CABLE at 75°C: 230 Amps

Allowable Ampacity for 300-300-300-4/0 ALUMINUM SER CABLE at 90°C: 260 Amps

Applications:

Aluminum SER (Service Entrance) cable is commonly used for branch circuits and panel feeders in residential and commercial buildings. The voltage rating for this cable is 600 volts, and it is designed for use in wet and dry locations, with an operating temperature up to 90°C.

This specific 300-300-300-4/0 size is typically used for:

  • Main panel feeds in large residential buildings or light commercial buildings with up to 250A service.
  • Subpanel feeds for multi-unit dwellings, apartments, or larger residential properties.
  • Power distribution from meter bases to 250A panelboards in commercial settings.
  • Feeding high-power electrical equipment such as HVAC systems, electric furnaces, and large appliances.
  • Backup generator connections requiring a 250A-rated feeder.

Also Known As:

300-300-300-4/0 type r cable, 300-300-300-4/0 service entrance cable, 300-300-300-4/0 ser cable, 300-300-300-4/0 aluminum ser cable, 300-300-300-4/0 aluminum service entrance cable, 300-300-300-4/0 electrical entrance cable.

Standards:

  • Ampacities based on National Electric Code, 2005 edition, section 310-15 

  • 60°C when terminated to equipment for circuits rated 100 Amps or less or marked for 14 gauge through 1 gauge conductors 

  • 70°C when terminated to equipment for circuits rated over 100 Amps or marked for conductors larger than 1 gauge 

  • 90°C wet or dry locations 

  • For dwelling units, conductors shall be permitted at listed ampacities to be utilized as 120/240 volt, 3-wire, single phase service conductors that supply the total load 

  • UL 44

Construction

Conductors:

The 300-300-300-4/0 designation means this cable contains:

  • The conductors are compact stranded soft-drawn 8000 series aluminum, designed to transmit electric current.

Insulation:

Aluminum SER cable has a type XHHW-2 cross linked polyethylene (XLP) insulation. The conductors are cabled together with a bare aluminum ground and covered with a reinforced binder tape. For color code, see table B in the technical section. 

Assembly:

Two, three or four insulated conductors and a bare ground conductor cabled together and covered with a reinforced binder tape.

Jacket:

The cable jacket used in its design is Polyvinyl Chloride (PVC). The jacket protects the inner components of the cable from potentially damaging external forces. PVC is robust and resistant to oil, sunlight, water, flames, acids, chemicals, radiation, impact, abrasion, and weather changes. Sequential footage markings that help the user identify the appropriate length during installation are noted on the cable jacket.

Specifications:

  • Insulated Cond(s) Size AWG: 300

  • Bare Conductor Size AWG: 4/0

  • Nominal O.D. Inches: 1.719

  • Approx. Weight lb/1000FT: 1360 lbs

  • Ampacity at 90°C: 260 Amps

  • Ampacity in dwelling: 230 Amps

Compatible with Manufacturer

Priority Wire & Cable : 300-03ALUMG-R-SER
Omni Cable : SER300-3C-4/0

*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet

FAQ's

What does 300-300-300-4/0 AL SER mean?

Two 300 kcmil aluminum hots, one 300 kcmil aluminum neutral, and one 4/0 AWG aluminum equipment grounding conductor.

What is SER cable?

SER is a NEMA and UL type designation for Service Entrance cable, Style R. "SE" identifies it as service entrance cable, and "R" designates the construction style: the individually insulated conductors are cabled together and covered by a moisture and flame-resistant jacket over a reinforcement tape or braid layer. This distinguishes it from Style U (SEU), where a bare concentric neutral is wound around the insulated conductors under the jacket. SER is rated 600V and governed by NEC Article 338.

Does 300-300-300-4/0 AL SER include a ground wire?

Yes. The 4/0 AWG conductor is the equipment grounding conductor.

Can I use 300-300-300-4/0 AL SER for a subpanel?

Yes, for a subpanel with a load up to approximately 285A.

Can AL SER cable be used in conduit?

Yes. AL SER is permitted in conduit where physical protection is required. Ampacity adjustment factors in NEC 310.15(C)(1) apply once more than three current-carrying conductors share the raceway.

Is AL SER cable rated for outdoor use?

Yes, most modern AL SER is listed for outdoor use when properly supported and protected from physical damage per NEC 338.10 and 230.51.

Is AL SER cable rated for wet locations?

AL SER manufactured with XHHW-2 insulated conductors is rated for wet locations. Standard XHHW or THHN versions are dry-location only.

Does interior AL SER need to be in conduit?

No. Interior AL SER can be run exposed or concealed following the installation methods for NM cable under NEC Article 334.

How far can I run 300-300-300-4/0 AL SER before voltage drop becomes a problem?

At 285A on 240V, approximately 178 feet within 3% drop.

What are the permitted uses for 300-300-300-4/0 AL SER?

300-300-300-4/0 AL SER is used for large commercial and industrial service entrance runs and heavy feeders up to approximately 285A. Typical uses include service laterals to large residential and light commercial buildings, feeders to large subpanels or distribution equipment, and feeders to buildings with electric heat, EV charging infrastructure, or heavy motor loads. Installation follows NEC Article 338 with terminations rated for aluminum conductors at 75°C.

Reviews

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Get in Touch
Live Chat Get replies right away!
Email info@nassaunationalcable.com

Call Us: 1-516-482-6313    Text Us: 1-516-703-3460