6-6-6 ALUMINUM SER CABLE

6-6-6 ALUMINUM SER CABLE
Roll over image to Zoom
6-6-6 ALUMINUM SER CABLE
Roll over image to Zoom
6-6-6 ALUMINUM SER CABLE
SKU: NNC1686X
overstock-hot-deals

Availability: In stock

Min Length: 1 FT
Max Length: 10000 FT
Price:
Regular price
$1.20 /FT
Sale price
$1.20 /FT
Shipping Cost Calculated at Checkout. Standard Lead Time is 1 to 6 Business Days.
Free Shipping: On orders above $1000
Quantity must be 1 or more

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

Based on 20 reviews
90%
(18)
10%
(2)
0%
(0)
0%
(0)
0%
(0)
b
brian Batchelller
Great

Order went smoothly

a
alberto navarro
owner

no comment

S
STEVEN SCOTT

Good price,no issues with ordering or delivery

Where are we? 4 Continents 9 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Product Information
Specification

6-6-6 ALUMINUM SER CABLE

Allowable Ampacity for 6-6-6 ALUMINUM SER CABLE at 60°C: 40 Amps

Allowable Ampacity for 6-6-6 ALUMINUM SER CABLE at 75°C: 50 Amps

Allowable Ampacity for 6-6-6 ALUMINUM SER CABLE at 90°C: 60 Amps

Applications:

6-6-6 Aluminum SER cable is primarily used for residential and light commercial panel feeders and branch circuits. It is rated for 600V and designed for use in both wet and dry locations with an operating temperature of 90°C.

This particular 6-6-6 size, with an ampacity of up to 60 Amps, is commonly used for:

  • Subpanel feeds in homes, garages, and workshops.
  • Feeding breaker panels in small residential or light commercial buildings.
  • Power distribution from meter bases to panelboards.
  • Supplying power to mid-sized electrical appliances, such as HVAC systems and electric water heaters.

Also Known As:

6-6-6 type r cable, 6-6-6 service entrance cable, 6-6-6 ser cable, 6-6-6 aluminum ser cable, 6-6-6 aluminum service entrance cable, 6-6-6 electrical entrance cable.

Standards:

  • Ampacities based on National Electric Code, 2005 edition, section 310-15 

  • 60°C when terminated to equipment for circuits rated 100 Amps or less or marked for 14 gauge through 1 gauge conductors 

  • 70°C when terminated to equipment for circuits rated over 100 Amps or marked for conductors larger than 1 gauge 

  • 90°C wet or dry locations 

  • For dwelling units, conductors shall be permitted at listed ampacities to be utilized as 120/240 volt, 3-wire, single-phase service conductors that supply the total load 

  • UL 44

Construction

Conductors:

The "6-6-6" designation means this SER cable contains three conductors, each with a 6 AWG (American Wire Gauge) size:

All conductors are made of compact stranded 8000 series aluminum, which is lightweight, corrosion-resistant, and highly conductive.

Insulation:

Each insulated conductor is coated with XHHW-2 cross-linked polyethylene (XLPE) insulation, which provides:

  • High heat resistance (rated up to 90°C).
  • Moisture resistance for wet and dry locations.
  • Durability against mechanical stress and chemical exposure.

Assembly:

Two, three or four insulated conductors and a bare ground conductor cabled together and covered with a reinforced binder tape.

Jacket:

The cable jacket used in its design is Polyvinyl Chloride (PVC). The jacket protects the inner components of the cable from potentially damaging external forces. PVC is robust and resistant to oil, sunlight, water, flames, acids, chemicals, radiation, impact, abrasion, and weather changes. Sequential footage markings that help the user identify the appropriate length during installation are noted on the cable jacket.

Specifications:

  • Insulated Cond(s) Size AWG: 6

  • Bare Conductor Size AWG: 6

  • Nominal O.D. Inches: 0.650

  • Approx. Weight lb/1000FT: 150 lbs

  • Ampacity at 90°C: 60 Amps

  • Ampacity in dwelling: N/A


Compatible with Manufacturer

Priority Wire & Cable : 6-02ALUMG-SER
Houston Wire & Cable : HW022A00666
Southwire : 32667801
Omni Cable : SER6-3C-6

*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet

FAQ's

What does 6-6-6 AL SER mean?

Two 6 AWG aluminum hots and one 6 AWG aluminum neutral. A three-conductor configuration used for service or two-wire feeder applications.

What is SER cable?

SER is a NEMA and UL type designation for Service Entrance cable, Style R. "SE" identifies it as service entrance cable, and "R" designates the construction style: the individually insulated conductors are cabled together and covered by a moisture and flame-resistant jacket over a reinforcement tape or braid layer. This distinguishes it from Style U (SEU), where a bare concentric neutral is wound around the insulated conductors under the jacket. SER is rated 600V and governed by NEC Article 338.

Does 6-6-6 AL SER include a ground wire?

No. 6-6-6 is a three-conductor cable. For subpanel and feeder applications requiring an equipment grounding conductor, use 6-6-6-6 AL SER.

What is the main difference between SER and SEU cable?

SER (Style R) has separate insulated hot and neutral conductors plus an equipment grounding conductor. This four-conductor construction makes SER suitable for runs from a main service panel to a subpanel, such as a panel in a detached garage, workshop, or another part of a building.

SEU (Style U) has insulated hot conductors surrounded by a bare concentric neutral and does not include a separate equipment grounding conductor. It is therefore mainly used on the service side of the electrical system, for example, between the meter and the main service panel, where neutral and ground are bonded at the service equipment.

What are the permitted uses for 6-6-6 AL SER?

6-6-6 AL SER is used for service entrance runs and two-wire feeder applications up to approximately 50A. Typical uses include the drop from the meter to a small main panel, or a feeder to a workshop or outbuilding where an equipment grounding conductor is not required. For subpanel feeders that need a four-wire connection, use 6-6-6-6 AL SER.

Can 6-6-6 AL SER be used for a subpanel?

No. Modern subpanel feeders require a separate equipment grounding conductor. Use 6-6-6-6 AL SER instead.

Can AL SER cable be used for direct burial?

No. Standard AL SER is not rated for direct burial. For underground runs, use USE or USE-2 cable, or install AL SER inside a listed underground raceway.

Does interior AL SER need to be in conduit?

No. Interior AL SER can be run exposed or concealed following the installation methods for NM cable under NEC Article 334. Conduit is required only where the cable is subject to physical damage.

How far can I run 6-6-6 AL SER before voltage drop becomes a problem?

At 50A on 240V, roughly 89 feet within 3% drop.

Where should service entrance conductors terminate?

Per NEC 230.70, service entrance conductors must terminate at the service disconnecting means, located at a readily accessible location either outside the building or inside nearest the point of entrance.

Reviews

Customer Reviews

Based on 20 reviews
90%
(18)
10%
(2)
0%
(0)
0%
(0)
0%
(0)
b
brian Batchelller
Great

Order went smoothly

a
alberto navarro
owner

no comment

S
STEVEN SCOTT

Good price,no issues with ordering or delivery

Get in Touch
Live Chat Get replies right away!
Email info@nassaunationalcable.com

Call Us: 1-516-482-6313    Text Us: 1-516-703-3460