300-300-300-300-4/0 Aluminum SER Service Entrance Cable
nassaunationalcable.com/en-ca/collections/al-ser-and-seu-cable/products/300-300-300-4-0-ser
Items in Cart ()
View cart

300-300-300-300-4/0 ALUMINUM SER CABLE

300-300-300-300-4/0 ALUMINUM SER CABLE
Roll over image to Zoom
300-300-300-300-4/0 ALUMINUM SER CABLE
Roll over image to Zoom
300-300-300-300-4/0 ALUMINUM SER CABLE
SKU: NNC1706X
aluminum-ser-service-entrance-type-r-cable

Availability: In stock

Min Length: 1 FT
Max Length: 10000 FT
Price:
Regular price
$15.26 /FT
Sale price
$15.26 /FT
Shipping Cost Calculated at Checkout. Standard Lead Time is 1 to 6 Business Days.
Free Shipping: On orders above $1000
Quantity must be 1 or more

Enter the required footage in the quantity box - Cut to one length

Where are we? 4 Continents 9 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Product Information
Specification

300-300-300-300-4/0 ALUMINUM SER CABLE

Allowable Ampacity for 300-300-300-300-4/0 ALUMINUM SER CABLE at 60°C: 195 Amps

Allowable Ampacity for 300-300-300-300-4/0 ALUMINUM SER CABLE at 75°C: 230 Amps

Allowable Ampacity for 300-300-300-300-4/0 ALUMINUM SER CABLE at 90°C: 260 Amps

Also Known As:

300-300-300-300-4/0 type r cable, 300-300-300-300-4/0 service entrance cable, 300-300-300-300-4/0 ser cable, 300-300-300-300-4/0 aluminum ser cable, 300-300-300-300-4/0 aluminum service entrance cable, 300-300-300-300-4/0 electrical entrance cable, 300-300-300-300-4/0 electrical entrance cable, 300 MCM aluminum service cable, 300-300-300-300-4/0 aluminum wire, 230 amp aluminum wire, 300-300-300-300-4/0 aluminum ser service entrance cable, 300-300-300-300-4/0.

300-300-300-300-4/0 Aluminum SER Cable Applications:

Aluminum service entrance cable is mainly used in branch circuits and panel feeders. The voltage rating for this electrical cable is 600 volts. Aluminum service entrance cables are designed for use in adverse weather conditions, with operating temperatures being 90°C in both wet and dry locations.

However, type R cables can operate at 60°C when terminated to equipment for circuits rated at 100 Amps or less or if it is marked for 14 gauge through 1 gauge conductors. In addition, SER cables can operate at 70°C when the electrical cable is terminated to equipment in circuits rated over 100 Amps or when marked for conductors larger than 1 gauge.

SER Cable Applications include:

  • Main Feeder Line From a Service Drop To Panel
  • Sub-panel Feeders
  • Large Appliances like ranges, air conditioning units, furnaces, and other large electrical loads.
  • Workshops and Detached Buildings
  • Agricultural Applications: SER cables can be employed in barns, greenhouses, and other agricultural structures to provide power for equipment, lighting, and other needs.
  •  Multi-Unit Dwellings: In multi-unit residential buildings, SER cable can serve as the main feeder or distribution cable to individual units.
  • Commercial Buildings: In commercial settings, SER cable can be utilized in a similar manner as residential – to serve as feeders to main panels or sub-panels, and to power specific high-load areas or equipment.

Particular Applications of 300-300-300-300-4/0 Aluminum SER:

  • Large Residential Service Entrance
  • Commercial Buildings
  • Underground Feeds
  • Service to Subpanels

300-300-300-300-4/0 Aluminum SER Standards:

  • Ampacities based on National Electric Code, 2005 edition, section 310-15 
  • 60°C when terminated to equipment for circuits rated 100 Amps or less or marked for 14 gauge through 1 gauge conductors 
  • 70°C when terminated to equipment for circuits rated over 100 Amps or marked for conductors larger than 1 gauge 
  • 90°C wet or dry locations 
  • For dwelling units, conductors shall be permitted at listed ampacities to be utilized as 120/240 volt, 3-wire, single phase service conductors that supply the total load 
  • UL 44

300-300-300-300-4/0 Aluminum SER Construction

Conductors:

Aluminum type R cable has compact strand soft drawn 8000 series aluminum conductor, per ASTM B-801. The conductor is the electrode in the cable and is responsible for transmitting electric current. 

Insulation:

Aluminum SER cable has a type XHHW-2 cross linked polyethylene (XLP) insulation. The conductors are cabled together with a bare aluminum ground and covered with a reinforced binder tape. For color code, see table B in the technical section. 

Assembly:

Two, three or four insulated conductors and a bare ground conductor cabled together and covered with a reinforced binder tape.

Jacket:

The cable jacket used in its design is Polyvinyl Chloride (PVC). The jacket protects the inner components of the cable from potentially damaging external forces. PVC is robust and resistant to oil, sunlight, water, flames, acids, chemicals, radiation, impact, abrasion, and weather changes. Sequential footage markings that help the user identify the appropriate length during installation are noted on the cable jacket.

300-300-300-300-4/0 Aluminum SER Specifications:

  • Insulated Cond(s) Size AWG: 300
  • Bare Conductor Size AWG: 4/0
  • Nominal O.D. Inches: 1.719
  • Approx. Weight lb/1000FT: 1360 lbs
  • Ampacity at 90°C: 260 Amps
  • Ampacity in dwelling: 230 Amps

*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet

FAQ's

What does 300-300-300-4/0 AL SER mean?

Two 300 kcmil aluminum hots, one 300 kcmil aluminum neutral, and one 4/0 AWG aluminum equipment grounding conductor.

What is SER cable?

SER is a NEMA and UL type designation for Service Entrance cable, Style R. "SE" identifies it as service entrance cable, and "R" designates the construction style: the individually insulated conductors are cabled together and covered by a moisture and flame-resistant jacket over a reinforcement tape or braid layer. This distinguishes it from Style U (SEU), where a bare concentric neutral is wound around the insulated conductors under the jacket. SER is rated 600V and governed by NEC Article 338.

Does 300-300-300-4/0 AL SER include a ground wire?

Yes. The 4/0 AWG conductor is the equipment grounding conductor.

What is the main difference between SER and SEU cable?

SER (Style R) includes a separate insulated neutral plus an equipment grounding conductor, making it suitable for feeders and subpanels. SEU (Style U) uses a bare concentric neutral and is limited to service entrance runs.

Can 300-300-300-4/0 AL SER be used for a subpanel?

Yes, for a subpanel with a load up to approximately 285A.

Can AL SER cable be used in conduit?

Yes. AL SER is permitted in conduit where physical protection is required. Ampacity adjustment factors in NEC 310.15(C)(1) apply once more than three current-carrying conductors share the raceway.

Can AL SER cable be used for direct burial?

No. Standard AL SER is not rated for direct burial. For underground runs, use USE or USE-2 cable, or install AL SER inside a listed underground raceway.

Does interior AL SER need to be in conduit?

No. Interior AL SER can be run exposed or concealed following the installation methods for NM cable under NEC Article 334.

How far can I run 300-300-300-4/0 AL SER before voltage drop becomes a problem?

At 285A on 240V, approximately 178 feet within 3% drop.

Where should service entrance conductors terminate?

Per NEC 230.70, service entrance conductors must terminate at the service disconnecting means, located at a readily accessible location either outside the building or inside nearest the point of entrance.