XHHW-2 Aluminum Building Wire 600V | Nassau Cable
nassaunationalcable.com/en-ca/products/xhhw-2
Items in Cart ()
View cart

XHHW-2 Aluminum Building Wire 600V

XHHW-2 Aluminum Building Wire 600V
Roll over image to Zoom
XHHW-2 Aluminum Building Wire 600V
Roll over image to Zoom
XHHW-2 Aluminum Building Wire 600V
Roll over image to Zoom
XHHW-2 Aluminum Building Wire 600V
Roll over image to Zoom
XHHW-2 Aluminum Building Wire 600V
Roll over image to Zoom
XHHW-2 Aluminum Building Wire 600V
Roll over image to Zoom
XHHW-2 Aluminum Building Wire 600V
Roll over image to Zoom
XHHW-2 Aluminum Building Wire 600V
Roll over image to Zoom
XHHW-2 Aluminum Building Wire 600V
Roll over image to Zoom
XHHW-2 Aluminum Building Wire 600V
SKU: NNC3142X

Where are we? 4 Continents 8 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

  Product Name Length Price (Per FT.) Action
8 AWG XHHW-2 Aluminum Building Wire 600V
Product Name

8 AWG XHHW-2 Aluminum Building Wire 600V

Length
/FT
Price (Per FT.)

$0.58

Available
Min: 150 FT
Max: 1000000 FT
Action

6 AWG XHHW-2 Aluminum Building Wire 600V
Product Name

6 AWG XHHW-2 Aluminum Building Wire 600V

Length
/FT
Price (Per FT.)

$0.60

Available
Min: 100 FT
Max: 1000000 FT
Action

4 AWG XHHW-2 Aluminum Building Wire 600V
Product Name

4 AWG XHHW-2 Aluminum Building Wire 600V

Length
/FT
Price (Per FT.)

$0.62

Available
Min: 100 FT
Max: 1000000 FT
Action

3 AWG XHHW-2 Aluminum Building Wire 600V
Product Name

3 AWG XHHW-2 Aluminum Building Wire 600V

Length
/FT
Price (Per FT.)

$0.78

Available
Min: 100 FT
Max: 1000000 FT
Action

2 AWG XHHW-2 Aluminum Building Wire 600V
Product Name

2 AWG XHHW-2 Aluminum Building Wire 600V

Length
/FT
Price (Per FT.)

$0.80

Available
Min: 100 FT
Max: 1000000 FT
Action

1 AWG XHHW-2 Aluminum Building Wire 600V
Product Name

1 AWG XHHW-2 Aluminum Building Wire 600V

Length
/FT
Price (Per FT.)

$0.90

Available
Min: 50 FT
Max: 1000000 FT
Action

1/0 AWG XHHW-2 Aluminum Building Wire 600V
Product Name

1/0 AWG XHHW-2 Aluminum Building Wire 600V

Length
/FT
Price (Per FT.)

$1.00

Available
Min: 50 FT
Max: 1000000 FT
Action

2/0 AWG XHHW-2 Aluminum Building Wire 600V
Product Name

2/0 AWG XHHW-2 Aluminum Building Wire 600V

Length
/FT
Price (Per FT.)

$1.20

Available
Min: 50 FT
Max: 1000000 FT
Action

3/0 AWG XHHW-2 Aluminum Building Wire 600V
Product Name

3/0 AWG XHHW-2 Aluminum Building Wire 600V

Length
/FT
Price (Per FT.)

$1.38

Available
Min: 30 FT
Max: 1000000 FT
Action

4/0 AWG XHHW-2 Aluminum Building Wire 600V
Product Name

4/0 AWG XHHW-2 Aluminum Building Wire 600V

Length
/FT
Price (Per FT.)

$1.64

Available
Min: 30 FT
Max: 1000000 FT
Action

250 MCM XHHW-2 Aluminum Building Wire 600V
Product Name

250 MCM XHHW-2 Aluminum Building Wire 600V

Length
/FT
Price (Per FT.)

$1.87

Available
Action

300 MCM XHHW-2 Aluminum Building Wire 600V
Product Name

300 MCM XHHW-2 Aluminum Building Wire 600V

Length
/FT
Price (Per FT.)

$2.58

Available
Action

350 MCM XHHW-2 Aluminum Building Wire 600V
Product Name

350 MCM XHHW-2 Aluminum Building Wire 600V

Length
/FT
Price (Per FT.)

$2.62

Available
Action

400 MCM XHHW-2 Aluminum Building Wire 600V
Product Name

400 MCM XHHW-2 Aluminum Building Wire 600V

Length
/FT
Price (Per FT.)

$3.04

Available
Action

500 MCM XHHW-2 Aluminum Building Wire 600V
Product Name

500 MCM XHHW-2 Aluminum Building Wire 600V

Length
/FT
Price (Per FT.)

$3.36

Available
Action

600 MCM XHHW-2 Aluminum Building Wire 600V
Product Name

600 MCM XHHW-2 Aluminum Building Wire 600V

Length
/FT
Price (Per FT.)

$4.30

Available
Action

700 MCM XHHW-2 Aluminum Building Wire 600V
Product Name

700 MCM XHHW-2 Aluminum Building Wire 600V

Length
/FT
Price (Per FT.)

$4.94

Available
Action

750 MCM XHHW-2 Aluminum Building Wire 600V
Product Name

750 MCM XHHW-2 Aluminum Building Wire 600V

Length
/FT
Price (Per FT.)

$5.12

Available
Action

900 MCM XHHW-2 Aluminum Building Wire 600V
Product Name

900 MCM XHHW-2 Aluminum Building Wire 600V

Length
/FT
Price (Per FT.)

$6.90

Available
Action

1000 MCM XHHW-2 Aluminum Building Wire 600V
Product Name

1000 MCM XHHW-2 Aluminum Building Wire 600V

Length
/FT
Price (Per FT.)

$7.40

Available
Action

Product Information
Specification

XHHW-2 Aluminum Building Wire 600V

Aluminum XHHW-2 is single-conductor building wire with cross-linked polyethylene (XLPE) insulation, made to be installed in conduit or other raceways. It's rated for wet and dry locations at up to 90°C and 600V, and it's offered in 8 AWG to 1000 MCM.

Applications:

Aluminum XHHW-2 is installed in conduit and other NEC-recognized raceways for services, feeders, and branch circuits, in wet or dry locations at up to 600V. Typical uses by size:

  • 8 to 4 AWG: 40A to 60A feeders to garage and shop subpanels, HVAC condensers and heat pumps, and EV charger circuits

  • 3 to 1 AWG: 100A and 110A home services (2 and 1 AWG) and 75A to 100A subpanel feeders

  • 1/0 to 4/0: 125A to 200A home services, manufactured home feeders, and 100A to 175A commercial feeders

  • 250 to 1000 MCM: 225A to 400A home services in a single run, commercial services and switchboard feeders in parallel sets, and solar inverter output feeders

  • Underground service laterals in PVC conduit from the meter to the main panel

  • Long feeder runs where aluminum's lower cost offsets upsizing for voltage drop

Also Known As:

Xhhw cable, hxxw cable, rw90 cable, rw90 wire, type se cable style u type xhhw, xhhw, southwire xhhw, xhhw insulation.

XHHW-2 Aluminum Data Center Applications

In data centers, aluminum XHHW-2 is used for the large feeders upstream of the racks, where its lower cost and weight add up across paralleled sets. Data center loads run continuously, so NEC 215.2 sizes feeders at 125% of the load unless the breaker is 100% rated. Terminations must be rated for aluminum.

  • 500 MCM: four parallel sets for 1200A service feeders, or two sets for a 400 kVA UPS input (601A at 125%)

  • 600 to 750 MCM: three parallel sets for 1000A service and distribution feeders, or two sets of 750 MCM for a 500 kVA UPS input (752A at 125%)

  • 900 and 1000 MCM: three or four parallel sets for 1200A and 1600A service feeders and main switchboards

  • Long feeders from outdoor generators to transfer switches and paralleling switchgear

Standards:

  • XHHW-2 meet or exceed the following standards: 
  • UL standard 44 
  • Requirements of the National Electrical Code 
  • ASTM standards B 800, B 801 
  • Federal Specification J–C-30B 
  • Sunlight resistant

Construction

Conductors:

Compact bare AA-8000 series aluminum alloy, Class B stranded per ASTM

Insulation:

XHHW-2 has abrasion, heat, and moisture resistant cross-linked polyethylene  XLPE insulation. Cross linking a polyethylene helps to achieve an excellent strength that makes the material suitable for covering this cable used in harsh conditions.


    *Data provided on this page is subject to change based on different manufacturers' variances
    ** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
    Download PDF Spec Sheet

    FAQ's

    What is aluminum XHHW-2 wire used for?

    Aluminum XHHW-2 is single-conductor building wire with cross-linked polyethylene (XLPE) insulation and an AA-8000 series aluminum alloy conductor, rated 600V and 90°C in wet or dry locations. It's used for services, feeders, and subpanel runs in conduit or other NEC-recognized raceways. Small sizes (8 to 4 AWG) feed subpanels, HVAC equipment, and EV chargers. 3 AWG through 4/0 cover 100A to 200A home services and outbuilding feeders. 250 to 1000 MCM carry commercial services and parallel feeders, where aluminum's lower cost and weight add up.

    What are the main differences between XHHW and XHHW-2 wires?

    Both use cross-linked polyethylene (XLPE) insulation and are rated 600V. The difference is the wet rating. XHHW is rated 90°C in dry locations but only 75°C in wet locations. XHHW-2 is rated 90°C in both, and it passes stricter UL 44 moisture testing. XHHW-2 can be used anywhere XHHW is allowed.

    What is the difference between THHN and XHHW-2 wire?

    Both THHN/THWN-2 and XHHW-2 are 600V building wires rated 90°C in wet and dry locations, so the real difference is the insulation. THHN/THWN-2 has thin PVC insulation with a nylon jacket. XHHW-2 has a single, thicker layer of cross-linked polyethylene (XLPE), a thermoset material that doesn't melt. XHHW-2 holds up better to abrasion, moisture, and cold. THHN/THWN-2 has a smaller diameter, so more conductors fit in the same conduit, and it usually costs less.

    What size aluminum XHHW-2 do I need for a 100A or 200A service?

    For a home, NEC 310.12 lets a 120/240V service be sized at 83% of its rating. That makes 2 AWG aluminum the standard size for 100A and 4/0 aluminum the standard size for 200A. For commercial and other non-dwelling services, use the full 75°C ampacity: 1 AWG aluminum for 100A and 250 MCM aluminum for 200A.

    What is the ampacity of aluminum XHHW-2 wire?

    Per NEC Table 310.16, with no more than three current-carrying conductors at 30°C ambient, here are the 75°C ratings of common sizes and what each is typically used for:

    • 6 AWG: 50A, for 50A subpanel circuits and 40A EV chargers
    • 2 AWG: 90A, the standard size for a 100A home service
    • 4/0: 180A, the standard size for a 200A home service
    • 350 MCM: 250A, for 250A feeders and 300A home services
    • 500 MCM: 310A, for 300A feeders and 600A services in two parallel sets
    Is aluminum XHHW-2 safe to use?

    Yes, when it's installed with the right terminations. The problems linked to aluminum wiring came from solid branch-circuit wire made in the 1960s and 1970s with an older alloy. Today's aluminum XHHW-2 uses AA-8000 series alloy, which NEC 310.3(D) requires for aluminum building wire from 8 AWG to 1000 MCM. Connected to lugs and breakers rated AL or AL/CU and torqued to the manufacturer's value, it performs reliably in services and feeders.

    Copper or aluminum XHHW-2: which should I choose?

    Copper carries more current for its size, so it fits in smaller conduit and connects to any standard terminal. Aluminum costs less and weighs much less, which matters on large feeders and long runs. Aluminum needs a larger size for the same load, usually about two sizes up: a 200A home service uses 2/0 copper or 4/0 aluminum. Copper is the usual choice for branch circuits and tight spaces, and aluminum is common for services and feeders 1/0 and larger.

    What colors does aluminum XHHW-2 come in?

    Aluminum XHHW-2 is available in black, red, blue, brown, orange, yellow, white, gray, and green, which makes phase identification easier. A common convention is black, red, and blue for 208Y/120V systems, brown, orange, and yellow for 480Y/277V systems, white or gray for neutrals, and green for equipment grounding conductors.

    Can XHHW-2 wire be buried underground?

    Not directly. XHHW-2 is not rated for direct burial, so it can't go in a trench without conduit. It can be installed underground inside conduit, because underground raceways are wet locations and XHHW-2 is rated 90°C wet. For burial without conduit, use a direct burial cable such as USE-2 or URD.

    Does XHHW-2 wire have to be run in conduit?

    Yes. XHHW-2 is a single-conductor building wire meant for conduit or other recognized raceways. It can't be run exposed outdoors or fished through walls like NM cable, so inside a wall it has to be in conduit, such as EMT or flexible metal conduit. The NEC allows a few exceptions, such as cable tray for 1/0 AWG and larger conductors with a CT marking, or open wiring on insulators, but these are uncommon.

    Is XHHW-2 wire sunlight resistant?

    Yes. NNC's XHHW-2 is marked sunlight resistant, so it holds up in conduit runs exposed to the sun and where the wire leaves the conduit, such as at a weatherhead. Sunlight resistance doesn't replace the conduit requirement.

    Can XHHW-2 wire be used in cold weather?

    Yes. XLPE insulation stays flexible in the cold much better than PVC-insulated THHN, which makes XHHW-2 easier to pull in winter. It's commonly rated for installation down to -40°C (-40°F). Check the spec sheet for the exact minimum.

    Is aluminum XHHW-2 used in data centers?

    Yes, mainly in large sizes. Aluminum XHHW-2 from 500 to 1000 MCM is used in parallel sets for utility service feeders to main switchgear, UPS inputs, and long runs from outdoor generators, where its lower cost and weight add up across many conductors. Branch circuits to racks are usually copper. Terminations must be rated for aluminum.

    Reviews
    Get in Touch
    Live Chat Get replies right away!
    Email info@nassaunationalcable.com

    Call Us: 1-516-482-6313    Text Us: 1-516-703-3460