1000 MCM AWG XHHW-2 Aluminum Building Wire 600V | Nassau Cable
nassaunationalcable.com/en-ca/products/1000-mcm-awg-xhhw-2-aluminum-cable-600v
Items in Cart ()
View cart

1000 MCM XHHW-2 Aluminum Building Wire 600V

1000 MCM XHHW-2 Aluminum Building Wire 600V
Roll over image to Zoom
1000 MCM XHHW-2 Aluminum Building Wire 600V
Roll over image to Zoom
1000 MCM XHHW-2 Aluminum Building Wire 600V
Roll over image to Zoom
1000 MCM XHHW-2 Aluminum Building Wire 600V
Roll over image to Zoom
1000 MCM XHHW-2 Aluminum Building Wire 600V
Roll over image to Zoom
1000 MCM XHHW-2 Aluminum Building Wire 600V
Roll over image to Zoom
1000 MCM XHHW-2 Aluminum Building Wire 600V
Roll over image to Zoom
1000 MCM XHHW-2 Aluminum Building Wire 600V
Roll over image to Zoom
1000 MCM XHHW-2 Aluminum Building Wire 600V
Roll over image to Zoom
1000 MCM XHHW-2 Aluminum Building Wire 600V
SKU: NNC1886X
xhhw-2-aluminum-building-wire-600v

Availability: In stock

Price:
Regular price
$7.40 /FT
Sale price
$7.40 /FT
Shipping Cost Calculated at Checkout. Standard Lead Time is 1 to 6 Business Days.
Free Shipping: On orders above $1000
Quantity must be 1 or more

Enter the required footage in the quantity box - Cut to one length

Where are we? 4 Continents 9 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Product Information
Specification

1000 MCM XHHW-2 Aluminum Building Wire 600V

Allowable Ampacity for 1000 MCM XHHW-2 Aluminum Cable 600V at 75°C: 445 Amps

Allowable Ampacity for 1000 MCM XHHW-2 Aluminum Cable 600V at 90°C: 500 Amps

1000 MCM aluminum XHHW-2 is single-conductor building wire with cross-linked polyethylene (XLPE) insulation, made to be installed in conduit or other raceways. It's rated for wet and dry locations at up to 90°C and 600V.

Applications:

1000 MCM aluminum XHHW-2 is installed in conduit and other NEC-recognized raceways for services, feeders, and branch circuits, in wet or dry locations at up to 600V. It's rated 445A at 75°C and 500A at 90°C. CT - Rated Cable tray rated for 1/0 AWG and larger available upon request.

The particular applications of 1 000 kcmil wire are:

  • 400A services and feeders in a single run
  • 800A services run as two parallel sets
  • 1200A and 1600A services run as three or four parallel sets
  • Main switchboard feeds in data centers, warehouses, and industrial plants
  • Service entrance
  • Main feeder circuits
  • Major industrial equipment
  • Conduit systems
  • Busbars and power distribution systems
  • Massive renewable energy installations
  • Backup generators

1000 MCM XHHW-2 Aluminum Data Center Applications

In data centers, 1000 MCM aluminum XHHW-2 is used for long service and generator feeders, where its lower cost and weight add up across paralleled sets. Data center loads run continuously, so NEC 215.2 sizes feeders at 125% of the load unless the breaker is 100% rated.
Terminations must be rated for aluminum.

  • Three parallel sets for 1200A service feeders

  • Four parallel sets for 1600A main switchboards

  • Utility service entrance and generator feeders on large campuses

Also Known As:

1000 xhhw-2 cable, 1000 hxxw-2 cable, 1000 rw90 cable, 1000 rw90 wire, 1000 type se cable style u type xhhw-2, 1000 xhhw-2, 1000 southwire xhhw-2, 1000 xhhw-2 insulation, 1000 kcmil aluminum wire, 1 000 kcmil wire, 1000 mcm aluminum wire, xhhw-2, 2 general cable

Standards:

  • XHHW-2 meet or exceed the following standards: 
  • UL standard 44 
  • Requirements of the National Electrical Code 
  • ASTM standards B 800, B 801 
  • Federal Specification J–C-30B 
  • Sunlight resistant

Construction

Conductors:

Compact bare AA-8000 series aluminum alloy, Class B stranded per ASTM

Insulation:

XHHW-2 has abrasion, heat, and moisture resistant cross-linked polyethylene insulation. Cross linking a polyethylene helps to achieve an excellent strength that makes the material suitable for covering this cable used in harsh conditions.

Specifications:

  • Size AWG: 1000 MCM
  • Stranding: 58
  • Conductor Diameter Inches: 1.060
  • Insulation Thickness Inches: 0.080
  • O.D. Inches:  1.220
  • New Weight lb/1000FT: 1067 lbs
  • Ampacity at 75°C: 445 Amps
  • Ampacity at 90°C: 500 Amps

Compatible with Manufacturer

Houston item : Black : HW002A10001
Black : 1000-01XHHWBLACKAL
Priority Wire & Cable : Black : 1000-01XHHW-2-ALUM
Southwire : Black : 27842404
Orange :
66232199
Yellow :
66218699
Brown :
66218799
Gray : 66254199


*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet

FAQ's

What is 1000 MCM aluminum XHHW-2 used for?

XHHW-2 is single-conductor building wire with cross-linked polyethylene (XLPE) insulation, which is where the "X" in its name comes from. "HHW" stands for high heat and water resistance, and "-2" means it's rated 90°C in wet locations as well as dry. 1000 MCM aluminum XHHW-2 has a compact AA-8000 series alloy conductor, is installed in conduit or other NEC-recognized raceways at up to 600V, and is rated 445A at 75°C. It's used for 400A services and feeders, 800A to 1600A services in parallel sets, and main switchboard feeds.

What are the main differences between XHHW and XHHW-2 wires?

Both use cross-linked polyethylene (XLPE) insulation and are rated 600V. The difference is the wet rating. XHHW is rated 90°C in dry locations but only 75°C in wet locations. XHHW-2 is rated 90°C in both, and it passes stricter UL 44 moisture testing. XHHW-2 can be used anywhere XHHW is allowed.

What is the difference between THHN and XHHW-2 wire?

Both THHN/THWN-2 and XHHW-2 are 600V building wires rated 90°C in wet and dry locations, so the real difference is the insulation. THHN/THWN-2 has thin PVC insulation with a nylon jacket. XHHW-2 has a single, thicker layer of cross-linked polyethylene (XLPE), a thermoset material that doesn't melt. XHHW-2 holds up better to abrasion, moisture, and cold. THHN/THWN-2 has a smaller diameter, so more conductors fit in the same conduit, and it usually costs less.

Can XHHW-2 wire be buried underground?

Not directly. XHHW-2 is not rated for direct burial, so it can't go in a trench without conduit. It can be installed underground inside conduit, because underground raceways are wet locations and XHHW-2 is rated 90°C wet. For burial without conduit, use a direct burial cable such as USE-2 or URD.

Does XHHW-2 wire have to be run in conduit?

Yes, in standard building installations. XHHW-2 is a single-conductor building wire meant for conduit or other recognized raceways. It can't be run exposed outdoors or fished through walls like NM cable, so inside a wall it has to be in conduit, such as EMT or flexible metal conduit. The NEC allows a few exceptions, such as cable tray for 1/0 AWG and larger conductors with a CT marking, or open wiring on insulators, but these are uncommon.

Is XHHW-2 wire sunlight resistant?

Yes. NNC's XHHW-2 is marked sunlight resistant, so it holds up in conduit runs exposed to the sun and where the wire leaves the conduit, such as at a weatherhead. Sunlight resistance doesn't replace the conduit requirement.

Can XHHW-2 wire be used in cold weather?

Yes. XLPE insulation stays flexible in the cold much better than PVC-insulated THHN, which makes XHHW-2 easier to pull in winter. It's commonly rated for installation down to -40°C (-40°F). Check the spec sheet for the exact minimum.

Is 1000 MCM aluminum XHHW-2 used in data centers?

Yes. 1000 MCM aluminum XHHW-2 runs in three or four parallel sets for 1200A and 1600A service feeders and main switchboards on large campuses. Terminations must be rated for aluminum.

Reviews
Get in Touch
Live Chat Get replies right away!
Email info@nassaunationalcable.com

Call Us: 1-516-482-6313    Text Us: 1-516-703-3460