750 MCM 1C Bare Copper Unshielded EPR PVC 25KV 133% Gaalflex Type MV-105 Cable

Where are we? 4 Continents 8 Countries


Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Quick Support
Allowable Ampacity for 750 MCM 1C Bare Copper Unshielded EPR PVC 25KV 133% Gaalflex Type MV-105 Cable: 100 Amps
About:
105 Cable: This cable is a medium voltage power cable used for electrical power transmission. It is designed with a 750 MCM American Wire Gauge (AWG) single conductor, made of bare copper. This cable is unshielded, featuring Ethylene Propylene Rubber (EPR) insulation and a Polyvinyl Chloride (PVC) jacket. It is rated for 25KV (kilovolts) at 133% insulation level, suitable for high voltage needs.
Also Known As:
This cable may be referred to as a medium voltage power cable, 750 AWG single conductor bare copper cable, or EPR insulated PVC jacketed cable.
Application:
It is commonly used in power distribution networks, both in indoor and outdoor settings. Suitable for use in industrial, utility, and commercial applications, especially where high voltage and robust insulation are required.
Standards:
• UL 1072
• ICEA S-97-682
• ICEA S-93-639
Construction:
• Conductor: Compacted concentric soft drawn bare copper Class B acc. to ASTM
• Inner semi-conductive layer: semi-conductive extruded thermosetting polymeric layer
• Insulation: Special rubber EPR compound
• Outer semi-conductive layer: semi-conductive extruded thermosetting polymeric layer
• Screen: Red copper tape
• Outer Sheath: Black (RAL 9005), special PVC compound
Features:
• Suitable for Direct buried, aerial installation, cable trays (CT)*, troughs or raceways *(CT use 1/0 AWG and larger)
• Suitable for wet or dry locations
• Sunlight resistant
• On request compressed or compacted stranded conductors
• On request compacted concentric stranded aluminium conductor Class B acc. to ASTM
• On request LLDPE*, CPE or Halogen-free insulation *(UL does not recognize LLDPE AS MV.105)
• On request red copper wires screen
• On request oil resistant outer sheath
• On request low coefficent PVC outer sheath
• On request acc. to CSA C68.10 (FT4 250 MCM and larger, -40°C cold impact and cold bend)
• acc. to AIEC CS-8
• RoHS approval
Specifications:
• Cross section AWG/MCM: 1 x 750
• Outer-Ø ca.mm ± 10%: 48,3
• Nominal voltage UL: 5 kV 100%,133%, 8 kV 100%,133%, 15 kV 100%,133% 25 kV 100%,133% 35 kV 100%,133%
• Temperature range UL: operating: up to +105°C, emergency overload: up to +140°C, On short-circuit: up to +250°C
• Min. bending radius: 12 x d
• Cable Weight approx Lbs/Mft: 3588
• Part Number: 48321W7L010AFC