18 AWG 4P Copper Shielded TC-ER Drain PVC/CPE VNTC Instrumentation Cable 600V
Application:
• The cables can be used in trays, conduit, and wireways. They are sunlight resistant and suitable for direct burial. They are available with a PVC or CPE jacket.
Scope:
• These 600 volt Instrumentation Cables are UL listed under Article 340 of the NEC and are suitable for cable tray use in Class 1, Division 2 hazardous locations. The cable can be used in wet or dry locations and up to conductor temperatures of 90°C. The addition of nylon over the conductors provides excellent oil and gasoline protection.
• The flame properties meet or exceed the requirements of both the UL 70,000 BTU vertical tray flame test and the comparable IEEE-383 flame test. A 210,000 BTU rating is also available upon request.
Also Known As:
18 AWG 4P Shielded VNTC Cable, 18 AWG 4P PVC/CPE Instrumentation Cable, 18 AWG 4P 600V VNTC Control Cable, 600V Shielded Instrumentation Tray Cable, 18 AWG 4P TC-ER Shielded Instrument Cable, 18 AWG 4P VNTC Shielded Tray Cable, 18/4P600V Shielded Control Cable, PVC/CPE Instrumentation Cable, Tray Rated Copper Shielded Cable, Exposed Run Tray Cable (TC-ER),Shielded Control Cable with Drain Wire.
Construction:
• Class B, stranded per ASTM B-3 and ASTM B-8. Conductors are type FN listed under UL 62. Triads are twisted with staggered lays to reduce crosstalk. Available in tinned copper upon request.
Primary insulation:
• 105°C rated PVC and nylon jacket
Shielding:
• Overall shield is helically applied with 100% coverage with a tinned copper drain wire.
Overall Jacket:
• PVC or CPE (90°C rated)
• Ripcord is applied under the jacket to facilitate stripping.
Specifications:
• AWG: 18
• No. of Pairs: 4
• Nominal Jacket Thickness (In): .047
• Nominal Outside Diameter (In): .442
• Pulling Tension (Pounds): 116
• Nominal Weight 1000 FT (Pounds): 114
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color