Okoguard Strand Aluminum Shield Neutral EPR Concentric BC PE URO-J 25KV URD Cable
Select a Gauge
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Name | Length | Price (Per FT.) | Action | |
---|---|---|---|---|
Product Name |
Length
/Qty
|
Price (Per FT.)
Call 516-482-6313 for pricing
|
Action
|
|
Product Name |
Length
/Qty
|
Price (Per FT.)
Call 516-482-6313 for pricing
|
Action
|
|
Product Name |
Length
/Qty
|
Price (Per FT.)
Call 516-482-6313 for pricing
|
Action
|
|
Product Name |
Length
/Qty
|
Price (Per FT.)
Call 516-482-6313 for pricing
|
Action
|
|
Product Name |
Length
/Qty
|
Price (Per FT.)
Call 516-482-6313 for pricing
|
Action
|
|
Product Name |
Length
/Qty
|
Price (Per FT.)
Call 516-482-6313 for pricing
|
Action
|
Product Information
Specification
About:
The Okoguard Strand Aluminum Shield Neutral EPR Concentric BC PE URO-J 25KV URD Cable is a high-performance underground distribution cable designed for primary distribution systems. It combines the benefits of a stranded aluminum conductor with an ethylene propylene rubber (EPR) insulation, providing excellent electrical properties, flexibility, and moisture resistance. The cable is suitable for direct burial or duct installations and is engineered to meet stringent safety and reliability standards.
Also Known As:
• Okoguard URD Cable
• 25KV URD Okoguard Cable
• Okoguard EPR URD Cable
Application:
• Okoguard URO-J cables provide maximum circuit longevity in underground residential distribution systems. They can be buried directly or installed in underground ducts or conduits.
Standards:
• ICEA S-94-649: Standard for concentric neutral cables rated 5 through 46 kV
• AEIC CS8: Specification for extruded dielectric shielded power cables rated 5 through 46 kV
• UL 1072: Standard for medium-voltage power cables
• IEEE 1202/FT4: Standard for flame propagation testing of wire & cable
• NESC: National Electrical Safety Code
Construction:
• Central Conductor: Aluminum per ASTM B609, Class B stranded per B-231.
• Conductor Screen: Extruded semiconducting ethylene-propylene rubber meets or exceeds the requirements of ICEA S-94-649, AEIC CS8, and CSA C68.5.
• Insulation: Extruded Okoguard meets or exceeds the requirements of ICEA S-94-649, AEIC CS8, and CSA C68.5
• Insulation Screen: Extruded semiconducting ethylene-propylene rubber meets or exceeds the requirements of ICEA S-94-649, AEIC CS8, and CSA C68.5.
• Concentric Conductor: Bare copper wires.
• Jacket: Black Okolene with red extruded stripes meets or exceeds the requirements of ICEA S-94-649, AEIC CS8, and CSA C68.5 for polyethylene jackets.
Features:
• Triple tandem extruded, all EPR system.
• Okoguard cables meet or exceed ICEA standards.
• Meets RUS 1728.204 for cables with filled strand or solid conductor and 100% insulation level.
• 105°C continuous operating temperature.
• 140°C emergency rating.
• 250°C short circuit rating.
• Excellent corona resistance.
• Low dielectric constant and power factor.
• Screens are clean stripping.
• Exceptional resistance to "treeing".
• Moisture resistant.
• Overall jacket provides extended life.
• Red extruded stripes.
• Excellent resistance to most chemicals.
• Can be listed by UL as Type MV-90 on Special Orders.
• CSAC68.5 listed, LTGG (-40°C), SR.
• Design Options:
• Additional conductor sizes
• Filled strand
• Copper central conductor
• Copper flat strap concentric neutral
• Product identification via colored jackets
• Semiconducting jackets
• Improved Temperature Rating. Okoguard insulation system has been tested and qualified for operation at 105°C continuous and 140°C emergency operating temperature.
• Minimum installation temperature of -40°C.
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
Download PDF Spec Sheet
Reviews