Igus MAT9850805 26/4P 26/4C Coupling Pin A / Round Plug Socket B Connector PUR Fagor iXC-C8-F-C9 Measuring Extension Cable

Where are we? 4 Continents 8 Countries


Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Quick Support
Igus MAT9850805 26/4P 26/4C Coupling Pin A / Round Plug Socket B Connector PUR Fagor iXC-C8-F-C9 Measuring Extension Cable
Allowable AmpacityĀ for Igus MAT9850805 26/4P 26/4C Coupling Pin A / Round Plug Socket B Connector PUR Fagor iXC-C8-F-C9 Measuring Extension Cable: 100 Amps
Also Known as:Ā
ExtensionĀ Connector, Igus Extension Connector, IGUS, Igus SUB-D Connector,Ā IgusĀ Connector, Measuring Extension Cable
Construction:
ā¢ Conductor:Ā Stranded conductor in especially bending-resistant version consisting of tinned copper wires (following DIN EN 60228).
ā¢ Conductor Insulation:Ā Mechanically high-quality TPE mixture
ā¢Ā Conductor Construction:Ā According to measuring system specification
ā¢ Conductor Identification:Ā According to measuring system specification
ā¢ Overall shield:Ā Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical.
ā¢ Jacket Color:Ā Yellow-green (similar to RAL 6018)
ā¢ Outer jacket:Ā Low-adhesion, halogen-free, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in energy chainsĀ® (following DIN EN 50363-10-2).
Properties and Approvals:
ā¢Ā UV resistance:Ā Medium
ā¢Ā Oil Resistance:Ā Oil-resistant according to DIN EN 50363-10-2
ā¢Ā Offshore:Ā MUD-resistant following NEK 606 - status 2009
ā¢Ā Flame retardant:Ā According to IEC 60332-1-2, CEI 20-35, VW-1, FT-1
ā¢Ā Silicone-free:Ā Free from silicon which can affect paint adhesion (according to PV 3.10.7 ā status 1992).
ā¢Ā Halogen-free:Ā Following EN 60754
ā¢ UL/CSA AWM:Ā See data sheet for details
ā¢Ā NFPA 79:Ā Following NFPA 79-2012 chapter 12.9
ā¢Ā DNV:Ā Certified to DNV type examination ā certificate no.: 13 656-14 HH
ā¢Ā EAC: Certified to no. TC RU C-DE. ME77.B.01559
ā¢Ā CTP:Ā Certified to no. C-DE.PB49.B.00416
ā¢Ā Lead free:Ā Following 2011/65/EU (RoHS-II)
ā¢Ā CEI:Ā Following CEI 20-35
ā¢Ā Clean room:Ā According to ISO Class 1. Outer jacket material complies with CF240.02.24, tested by IPA according to standard 14644-1
ā¢Ā CE Guideline:Ā Following 2014/35/EU
Specification:
AWG size:Ā 26
Number of Conductor:Ā 4
AWG size:Ā 26
Number of Pair:Ā 4
Conductor:Ā TinnedĀ Copper
Insulation:Ā TPE
Jacket:Ā PUR
Outer Diameter: 0.43 inch
Copper Index: 52.4 lbs/mft
Voltage:Ā 50 V
Weight: 102.1 lbs/mftĀ
Part Number: MAT9850805
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460