8 AWG 168 Strand Tinned Copper XLPE RW90 Machine Flex Power Wire
Where are we? 4 Continents 9 Countries

Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Quick Support
8 AWG 168 Strand Tinned Copper XLPE RW90 Machine Flex Power Wire
Applications:
Type XHHW-2 & RW90 conductors are primarily used in conduit, cable tray or other recognized raceways for service, feeders, and branch circuit wiring as specified in the National Electric Code (NEC) and the Canadian Electrical Code (CE Code). XHHW-2 & RW90 conductors may be used at conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. Voltage rating for XHHW-2 conductors is 600 volts and 1000 volts. Voltage rating for RW90 conductors is 600 volts. Flexible tinned copper stranding allows for ease of installation in locations with limited space, as well as including for use in electrical equipment for industrial facilities with harsh chemical environments, telecommunications applications and data centers.Type XHHW-2 600 Volts or 1000 Volts and Type RW90 600V. Rated 90°C Dry/Wet, -40°C. Flexible Tinned Copper Conductors.Cross-Linked Polyethylene (XLPE) Insulation. Rated High-Heat, Flame, Moisture, Gasoline, Oil and Sunlight Resistant.
Also Known As:
8 AWG Tinned Copper RW90 Machine Flex Cable XLPE RW90 Flexible Power Wire RW90 Tinned Copper Power Cable 8 AWG Machine Flex XLPE Power Cable Flexible RW90 XLPE Copper Wire Tinned Copper XHHW-2 / RW90 Power Wire Industrial Machine Flex RW90 Cable 8 AWG XLPE Insulated Tinned Copper Machine Wire Flexible Tinned Copper Industrial Power Cable RW90 600V Machine Flex Cable XHHW-2 / RW90 Flexible Power Conductor Fine-Stranded Tinned Copper XLPE Power Cable
Standards:
• ASTM B3 Soft or Annealed Copper Wire
• ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
• ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors
• UL 44 Thermoset-Insulated Wires and Cables
• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger)
• CSA C22.2 No. 38 Thermoset-insulated wires and cables
• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
• CE/RoHS-2 – The CE Marking has been applied solely to express the conformance to the material restrictions identified in the RoHS-2 (2011/65/EU) Directive
• Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661
• Sunlight Resistance
Construction:
1. Conductors: 8 AWG - 4/0 AWG: Class K, Flexible Stranded, Softdrawn Tinned Copper. 250 KCMIL - 750 KCMIL; Class I, Flexible Concentric Ropelay Stranded, Softdrawn Tinned Copper
2. Insulation: Black, Sunlight, Gas & Oil Resistant Cross-Linked Polyethylene (XLPE)
Specifications:
• Size: 8 AWG
• Number of Strands: 168
• Diameter Over Conductor inch : 0.153
• Insul Thickness (mil): 45
• Insulation Color : BK
• Approx. OD (inch) : 0.243
• Copper Weight lb/1000ft : 52
• Approx. Weight lb/1000ft : 66
• Min Bending Radius inch : 0.9
• Max Pull Tension lb : 132
• DC Resistance @ 25°C: 0.715
• AC Resistance @ 75°C : 0.861
• Inductive Reactance@ 60Hz : 0.052
• Allowable Ampacity At 75°C Amp : 50
• Allowable Ampacity At 90°C Amp : 55
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460