750 MCM 1C Stranded Bare Copper Tape Shield PO Halogen-Free 18/30KV RE4H1M1 Medium Voltage Cable
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
750 MCM 1C Stranded Bare Copper Tape Shield PO Halogen-Free 18/30KV RE4H1M1 Medium Voltage Cable
Allowable Ampacity for 750 MCM 1C Stranded Bare Copper Tape Shield PO Halogen-Free 18/30KV RE4H1M1 Medium Voltage Cable: 100 Amps
About:
RE4H1M1 Stranded Bare Copper Tape Shield PO Halogen-Free Medium Voltage Cable is designed for medium voltage power distribution systems. It is constructed with a stranded bare copper conductor and features a polyolefin (PO) insulation material. The cable is also equipped with a bare copper tape shield for protection against electrical interference and environmental factors.
Also Known As:
• Medium Voltage Copper Tape Shielded Cable
• Halogen-Free MV Power Cable
• RE4H1M1 Cable
Application:
• Power distribution networks
• Industrial plants
• Underground installations
• Outdoor installations
• Renewable energy projects
Standards:
• IEC 60502 (International Electrotechnical Commission)
• IEEE 1202 (Institute of Electrical and Electronics Engineers)
• UL 1072 (Underwriters Laboratories)
• BS 6622 (British Standard)
Construction:
• Conductor: stranded red copper conductor Cl.2, acc.to IEC 60228
• Inner semi-conductive layer: extruded semi-conducting compound
• Insulation: XLPE compound
• Outer semi-conductive layer: extruded semi-conducting compound
• Screen: red copper wires and one or two copper tape(s) applied helically, if necessary
• Outer sheath: red (RAL 3000), thermoplastic polyolefine halogen-free type M1
Features:
• according to IEC 60502-2
Specifications:
• AWG No: 750 MCM
• No.of cores x cross section n x mm2: 1x400
• Outer-Ø ca.mm ± 10%: 46,5
• Nominal voltage: Uo/U 3,6/6 kV, Uo/U 6/10 kV
Uo/U 8,7/15 kV, Uo/U 12/20 kV,
Uo/U18/30 kV
• Test voltage: Uo/U 3,6/6 kV = 11 kV
Uo/U 6/10 kV = 17 kV
Uo/U 8,7/15 kV = 24 kV
Uo/U 12/20 kV= 29 kV
Uo/U 18/30 kV = 45 kV
• Temperature range: -5 o C up to + 90 o C
• Min. bending radius: 14 x d
• Cable weight approx. kg/km: 5030
• Part Number: 48160XRL010M73
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet
Reviews
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460