63 Cable Gland PX2KX Epoxy Metal Armour Clamping Barrier And Tape Expl
nassaunationalcable.com/en-ca/products/63-cable-gland-px2kx-epoxy-metal-armour-clamping-barrier-and-tape-explosive-atmosphere

Items in Cart ()

View cart

63 Cable Gland PX2KX Epoxy Metal Armour Clamping Barrier And Tape Explosive Atmosphere

63 Cable Gland PX2KX Epoxy Metal Armour Clamping Barrier And Tape Explosive Atmosphere
Roll over image to Zoom

63 Cable Gland PX2KX Epoxy Metal Armour Clamping Barrier And Tape Explosive Atmosphere

SKU:

Select a Variant

63 Cable Gland PX2KX Epoxy Metal Armour Clamping Barrier And Tape Explosive Atmosphere
Price:
Shipping Cost Calculated at Checkout. Standard Lead Time is 1 to 6 Business Days.
Quantity must be 1 or more

Customer Reviews

No reviews yet
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Where are we? 4 Continents 8 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Chat

Live Chat: Bottom Right Corner!

Email Us

info@nassaunationalcable.com

Product Information

Specification

63 Cable Gland PX2KX Epoxy Metal Armour Clamping Barrier And Tape Explosive Atmosphere

Allowable Ampacity 
for 63 Cable Gland PX2KX Epoxy Metal Armour Clamping Barrier And Tape Explosive Atmosphere: 100 Amps

Also Known As:

Cable Gland, PX2KX Cable Gland, Epoxy Gland, Metal Armour Clamping Gland, Barrier Cable Gland, Explosive Atmosphere Gland

Construction:

• Design Specification: 
BS 6121:Part 1:1989, IEC 62444, EN 62444
• Mechanical Classifications *:
Impact = Level 8, Retention = Class B
• Enclosure Protection: 
IK10 to IEC 62262 (20 Joules) Brass & Stainless Steel Only
• Electrical Classifications *: 
Category B (Category A When Used With Braid, Tape or Pliable Wire Armour Cables)
• ATEX Certificate: 
SIRA13ATEX1072X, SIRA13ATEX4078X
• Code of Protection: 
II 2G, II 1D, Ex d IIC Gb, Ex e IIC Gb, Ex ta IIIC Da, II 3G Ex nR IIC Gc, IM2 Ex d I Mb, Ex e I Mb
• Compliance Standards: 
EN 60079-0,1,7,15,31
• IECEx Certificate: 
IECEx SIR 13.0027X, IECEx SIM 14.0008X
• Code of Protection: 
Ex d IIC Gb, Ex e IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da, Ex d I Mb, Ex e I Mb
• Compliance Standards: 
IEC 60079-0,1,7,15,31
• cCSAus Certificate (20s16 - 100): 
2288626
• CSAus Code of Protection***:
 Class I, Div. 1, 2 Groups A, B, C and D; Class II, Div. 1, 2 Groups E, F and G; Class III, Div. 1, 2; Type 4X: Oil Resistant II: Class I, Zone 1 AEx d IIC Gb, AEx e IIC Gb, Class I, Zone 2 AEx nR IIC Gc, Class I, Zone 20 AEx ta IIIC Da
• CSAus Code of Protection***: Class I, Div. 1, 2 Groups A, B, C and D; Class II, Div. 1, 2 Groups E, F and G; Class III, Div. 1, 2; Type 4X: Oil Resistant II: Ex d IIC Gb, Ex e IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da
• Code of Protection: Class I, Div 1,2, Groups A,B,C,D; Class II, Div 1,2, Groups E,F,G, Class III, Div 1,2; Class I Zone 1, AEx d IIC, AEx nR II, NEMA 4X , Oil Resistant II AEx d IIC Gb, AEx e IIC Gb, Class I, Zone 2 AEx nR IIC Gc, Class I, Zone 20 AEx ta IIIC Da
• Compliance Standards: CAN/CSA-C22.2 No 0,18,25,30,94,174, CAN/CSA-E60079-0,1,7,15,31 CAN/CSA-E61241-1-1 Part 1-1, ANSI/UL 514B Ed 5, ANSI/UL 50 Ed 11, ANSI/UL 2225 Ed 4, UL60079
• UL Certificate (20s16 - 100): E201187, E161256C
• Code of Protection: 
Class I Div 1,2, Groups A,B,C,D, Class II Div 1,2, Groups E,F,G
• Compliance Standards: 
UL 2225, CSA C22.2 No 174, UK 514B, CSA C22.2 No 18, CSA C22.2 No 30
• EAC Certificate (Formerly GOST R, K & B):
 TC RU C-GB.AA87.B.00487
• UkrSEPRO: UA.TR.047.C.0644-15
• KCC Certificate: 14-GA4BO-0252X
• CCOE / PESO (India) Certificate: P333688
• NEPSI Certificate: 
GYJ13.1140X, GYJ13.1282X
• INMETRO Certificate: 
TÜV 12.2073X
• RETIE Certificate: 
03866
• Marine Approvals: 
LRS: 01/00172, DNV: TAE00000Y, ABS: 14-LD234401A-4-PDA, BV: 43180/A1BV
• Ingress Protection Rating **: 
IP66, IP67 & IP68
• Deluge Protection Compliance: 
DTS01 : 91
• Cable Gland Material: 
Electroless Nickel Plated Brass, Brass, Stainless Steel, Aluminium
• Seal Material: 
CMP SOLO LSF Halogen Free Thermoset Elastomer / Epoxy Barrier Compound
• Cable Type:
 Screened Flexible (EMC) Wire Braid (e.g. CY / SY), Pliable Wire Armour (PWA), Steel Tape Armour (STA), Wire Braid Armour (e.g. SWB), Aluminium Strip Armour (ASA), Armoured & Jacketed***
• Armour Clamping: Detachable Compound Tube / Cone & AnyWay Universal Clamping Ring
• Sealing Technique: 
Unique CMP ‘LRS’ Outer Seal (Load Retention Seal)
• Sealing Area(s): 
Inner Compound Barrier & Outer Sheath
• Optional Accessories: 
Locknuts, Earth Tags, Serrated Washers, Entry Thread Seals, Shrouds, Ingress Discs
• Optional Installation Tools: 
Spanners

Globally Approved, Explosive Atmosphere Barrier Cable Gland:

Metal-to-Metal Armour Clamping
Direct & Remote Installation
Compound Barrier Type Flameproof Seal
Controlled Outer ‘Load Retention’ Seal
Unique OSTG Prevents Overtightening
Integral Protected Deluge Seal
-60°C to +85°C
Class I Zone 1, 21 and Zone 2, 22 Class I Division 1 & 2 ABCD
Globally Marked, IECEx, ATEX, UL & cCSAus
EMC Tested

Specification:

• Cable Gland Size: 63
• Available Entry Threads "C" (Alternate Metric Thread Lengths Available) Standard Metric: M63
• Available Entry Threads "C" (Alternate Metric Thread Lengths Available) Standard Thread Length (Metric) "E": 15.0
• Available Entry Threads "C" (Alternate Metric Thread Lengths Available) Standard NPT: 2 ½"
• Available Entry Threads "C" (Alternate Metric Thread Lengths Available) Standard Thread Length (NPT) "E": 39.9
• Available Entry Threads "C" (Alternate Metric Thread Lengths Available) Option NPT: 3"
• Number of Cores: 115
• Diameter Over Conductors "A": 53.7
• Cable Bedding Diameter "G" Max: 54.0
• Overall Cable Diameter "B" Min: 54.6
• Overall Cable Diameter "B" Max: 65.8
• Armour Range Grooved Cone (X) Min: 0.6
• Armour Range Grooved Cone (X) Max: 1.6
• Across Flats "D" Max: 80.0
• Across Corners "D" Max: 88.0
• Protrusion Length "F": 80.3
• Combined Ordering Reference (*Brass Metric) Size: 63
• Combined Ordering Reference (*Brass Metric) Type: PX2KX
• Combined Ordering Reference (*Brass Metric) Ordering Suffix: 1RA
• Shroud: PVC25
• Cable Gland Weight: 3.265 LBS