550 MCM 3C Stranded Aluminium Shield Overall BC Tape Red PE ARG7H1EX 18/30KV Medium Voltage Cable
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
550 MCM 3C Stranded Aluminium Shield Overall BC Tape Red PE ARG7H1EX 18/30KV Medium Voltage CableAllowable Ampacity for 550 MCM 3C Stranded Aluminium Shield Overall BC Tape Red PE ARG7H1EX 18/30KV Medium Voltage Cable: 100 Amps
About:
This description pertains to a medium voltage cable that is rated for 18/30 kV (kilovolts) applications, indicating its suitability for higher voltage requirements compared to standard commercial or residential cables. The "550 MCM AWG 3C" refers to a three-conductor cable where each conductor is 550 MCM American Wire Gauge (AWG) in size, denoting thick conductors that can handle larger current loads.
Also Known As:
Such a cable may be known by different names, reflecting its construction and application, such as "18/30 kV aluminum stranded medium voltage cable," "550 MCM AWG triple-core aluminum shielded cable," or "medium voltage power cable with red PE insulation." These alternate names can vary but generally convey the cable's primary characteristics and applications.
Application:
It is designed for significant electrical installations where medium to high voltage power transmission is required. Typical applications include power distribution networks, connecting substations to industrial, commercial, or residential complexes, and providing power in environments where durability and reliability are critical, such as underground, outdoor, or industrial settings.
Standards:
The cable should comply with international and national standards applicable to medium voltage power cables, ensuring its reliability, safety, and performance. This might include compliance with IEC 60502-2 for medium voltage cables or similar standards, dictating requirements for construction, performance, and testing.
Construction:
• Conductor: Stranded plain aluminium conductor Cl.2, acc. to IEC 60228
• Inner Semi-Conductive Layer: Extruded Elastomeric Compound
• Insulation: Special EPR type DIH2
• Outer Semi-Conductive Layer: : Extruded Elastomeric Compound
• Screen: Red copper wires and one or two copper tape(s) applied helically.
• Outer Sheath: Red(RAL 3000), PE type DMZ1
Features:
• According to IEC 60502-2
Specifications:
• No. of cores x cross section n x mm²: 3 x 1 x 300
• AWG no.: 550 MCM
• Outer-Ø ca.mm ± 10%: 90,6
• Nominal Voltage: Uo/U 12/20 kV, Uo/U 18/30 kV
• Test Voltage: Uo/U 12/20 kV = 29 kV, Uo/U 18/30 kV = 45 kV
• Max. Operating Voltage: Uo/U 12/20 kV = Um 24 kV, Uo/U 18/30 kV = Um 36 kV
• Temperature range: - 25° C up to + 105° C
• Max short circuit temperature: + 300° C
• Min. bending radius: 13 x d
• Max. tensile stress: 60 N/mm²
• Cable Weight approx. kg/km: 6120
• Part Number: 48050XRL030M71
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet
Reviews
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460