500 MCM 3C Type MV-105 Copper 15kV Cable with 3 Grounds NLEPR Insulation 133% IL ARMOR-X Red PVC Jacket

500 MCM 3C Type MV-105 Copper 15kV Cable with 3 Grounds NLEPR Insulation 133% IL ARMOR-X Red PVC Jacket
Roll over image to Zoom
500 MCM 3C Type MV-105 Copper 15kV Cable with 3 Grounds NLEPR Insulation 133% IL ARMOR-X Red PVC Jacket
SKU: NNC673465
type-mv-105-3-conductor-copper-15kv-cable-with-3-grounds-nlepr-insulation-133-il-armor-x-red-pvc-jacket
Min Length: 1 FT
Max Length: 10000 FT
Price:
Regular price
$0.00 /FT
Sale price
$0.00 /FT
Shipping Cost Calculated at Checkout. Standard Lead Time is 1 to 6 Business Days.
Free Shipping: On orders above $1000
Quantity must be 1 or more

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Where are we? 4 Continents 9 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Product Information
Specification

500 MCM 3C Type MV-105 Copper 15kV Cable with 3 Grounds NLEPR Insulation 133% IL ARMOR-X Red PVC Jacket

Applications:

The 15KV ARMOR-X with 50% ground are armored cables for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503. Cable is suitable for VFD applications. Type MV-105 Three Conductor Copper, 220 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, Tape Shield, Three Grounds, Continuous Corrugated Welded Aluminum Armor. -ARMOR-X, Polyvinyl Chloride (PVC) Jacket. Suitable For VFD Applications. Silicone Free.

Also Known As:

500MCM 3C 15kV Copper Armored Medium Voltage Cable,500 MCM 3C 15kV 3/C MV-105 EPR Cable, 500 MCM 3C 15kV Copper MC-HL Armored Cable,500 MCM 3C 15kV ARMOR-X Shielded Power Cable, 500-3C 15kV 3-Conductor Copper VFD Cable, 500-3C 15kV Copper Tape Shielded Cable with 3 Grounds.

Constructions:

 Conductor: Class B compressed stranded bare copper per ASTM B3 and B8 (Tinned Copper per ASTM B33 optional)
 Conductor Shield: Semi-conducting cross-linked copolymer
 Insulation: 220 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level
 Insulation Shield: Strippable semi-conducting cross-linked copolymer
 Copper Tape Shield: Helically wrapped 5 mil copper tape with 25% overlap
Grounding Conductor: Three separate ground wires with a combined ciurcular mil of 50% of the phase conductor. Class B compressed stranded bare copper per ASTM B3 and B8 (Tinned Copper per ASTM B33 optional)
 Filler: Wax paper filler
 Binder: Polypropylene tape
 Armor: ARMOR-X Continuous Corrugated Welded Aluminum Armor
 Overall Jacket: Polyvinyl Chloride (PVC).

Standards:

 ASTM B3 Soft or Annealed Copper Wire
 ASTM B8 Concentric-Lay-Stranded Copper Conductors
 ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
 UL 1072 Medium-Voltage Power Cables
 UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test
 ICEA S-58-679 Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)
 ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
 IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
 AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)
 Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661

Specification:

Conductor Size: 500 AWG
Strand: 37
Diameter Over Conductor: 0.789 inch
Diameter Over Insulation: 1.275  inch
Diameter Over Insulation Shield: 1.335 inch
Ground:  3x1 AWG
Diameter Over armor: 3.540 inch
Jacket Thickness: 85 mil
Approx. OD: 3.710 inch
Copper Weight(lb/1000ft): 5781
Approx. Weight(lb/1000ft): 9101
Max Pull Tension(lb): 12000
Min Bending Radius: 25.9 inch

Compatible with Manufacturer

Southwire 673465

*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet