500-500-300 Holyoke Triplex Aluminum Conductor Underground Direct Burial 600V URD

Where are we? 4 Continents 8 Countries


Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Quick Support
500-500-300 MCM Holyoke Triplex Aluminum Conductor Underground Direct Burial 600V URD
Allowable Ampacity for 500-500-300 MCM Holyoke Triplex Aluminum Conductor 600V URD direct burial: 495 Amps
Allowable Ampacity for 500-500-300 MCM Holyoke Triplex Aluminum Conductor 600V URD in duct: 395 Amps
Applications:
The Aluminum 600V URD is designed to serve in the secondary distribution circuits for power. In these secondary circuits, the electrical cable is installed in duct or direct burial applications. Due to its versatility, conductor strength, and insulation integrity, it works well for these outdoor applications. It is also used in wet and dry places since the electrical cable has a maximum operating temperature of 90°C. The triplex wire for sale is also designed to provide an option of pre-pulling into ducts.
Also Known As:
500-500-300 mcm holyoke aluminum urd cable, 500-500-300 mcm holyoke urd direct burial cable, 500-500-300 mcm holyoke three conductor cable, 500-500-300 mcm holyoke tri plex wire, 500-500-300 mcm holyoke triplex cable, 500-500-300 mcm holyoke triplex aluminum underground wire, 500-500-300 mcm holyoke 3 conductor power cable, 500-500-300 mcm holyoke aluminum triplex, 500-500-300 mcm holyoke underground triplex, 500-500-300 mcm holyoke triplex underground cable, 500-500-300 mcm holyoke triplex wire underground, 500-500-300 mcm holyoke direct burial triplex, 500-500-300 mcm holyoke triplex conductor, 500-500-300 mcm holyoke direct burial electrical cable, 500-500-300 mcm holyoke direct burial power cable, 500-500-300 mcm holyoke aluminum direct burial cable.
Standards:
-
ASTM B-230
-
ASTM B-231
-
ASTM B-609
-
ASTM B-901
-
ICEA S-105-692
-
J-C- 30B Federal Specification
-
RUS accepted
Construction
Conductors:
Aluminum conductors used for this cable are designed in either concentric strand or in compressed series. The advantage with a compressed conductor is the reduced bulkiness. Compressed conductors are also stronger and tougher; the stranded conductors are highly flexible and tend to have lower electrical resistance. Stranded conductors therefore reduce power loss and are also easier to use in applications where flexibility is vital. Aluminum 600 V URD cable has three aluminum conductors.
Insulation:
Versatile insulation system made of cross linked black polyethylene material helps to secure the cable conductors. This insulation is water tight, repulsive to corrosive substances, resistant to oil, heat and flame. Cross linking a polyethylene helps to achieve an excellent strength that makes the material suitable for covering this cable used in harsh conditions like direct burial installation.
Specifications:
-
Size AWG: 500
-
Stranding: 37
-
Insulation Thickness (mils): 95
-
Neutral Size AWG: 300
-
Single Phase Conductor Inches: 0.980
-
O.D. Inches: 2.117
-
Weight lbs./1000ft: 1.545 lbs
-
Ampacity: Direct burial: 495 Amps
-
Ampacity: In duct: 395 Amps
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460