500' 16 AWG 3C With 3/18 Ground Shielded XLP Insulation 600/1KV VFD Cable
Where are we? 4 Continents 9 Countries

Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Quick Support
Application:
Three Conductor Variable Frequency Drive Cables are primarily used with VFD’s. The three conductor construction is suitable for applications that are generally dry with one-phase fault conditions, where an insulated ground is not required. Three Conductor Variable Frequency Drive Cables DO NOT require Termination Kits.
Also known as:
16/3 Shielded VFD Power Cable, 16/3 Shielded Variable Frequency Drive Power Cable , 600/1kV Shielded Power Cable for Variable Frequency Drives, 16/3 Multi-Conductor Power Cable with Ground Shield for VFDs, 16/3 Shielded Control and Power Cable for VFD Systems, Heavy-Duty Shielded Power Cable for Industrial VFD Applications, XLP Insulated Shielded Power Cable for High-Voltage VFDs, 3-Conductor Shielded Power Cable with Ground Shield for VFDs, UL Type VFD Power Cable, UL 2/C Shielded Power Cable for VFDs, UL 600V Shielded Power Cable with Ground for VFD Applications, CSA Shielded Power Cable for Variable Frequency Drive Systems, Flexible Shielded Power Cable for Industrial Drives.
Standards:
• UL 1277, Type TC-ER, Type XHHW-2
• UL listed as VFD or WTTC per UL 2277 for Flexible Motor
Supply and Wind Turbine Tray Cables
• CSA FT-4 Vertical tray flame test
• CSA AWM I/II A/B singles
• CSA Type AWM per CSA standard C22.2 No. 210-11
• c(UL) CIC-TC per CSA standard C22.2 No. 239-09 & 230-09
• Meets UL 1202/1583 70,000 BTU flame test
• Meets ICEA T-29-520 210,000 BTU flame test
• Suitable for use in Class I Division II hazardous locations
• 90°C DRY/WET
• RoHS II & REACH compliant
Construction
Conductors:
• 16AWG-4AWG: Stranded soft drawn tinned copper
• 2AWG and larger: Stranded soft drawn bare copper
Ground(s):
• 16AWG-4AWG: Stranded soft drawn tinned copper
• 2AWG and larger: Stranded soft drawn bare copper
Insulation:
• Cross-linked polyethylene (XLP) insulation
Shielding:
• 16AWG-4AWG: Aluminum/Mylar/Aluminum tape 100%
coverage & tinned copper braid
• 2AWG and larger: 0.005” helical bare copper tape shield with a
50% overlap
Jacket:
• Black polyvinyl chloride (PVC) jacket that is sunlight,
moisture, oil and abrasion resistant, and direct burial rated.
• Rated for use from -40°C to 90°C
Specification:
- Size (AWG): 16
- Number of Strands: 26
- Ground Wire Size (AWG): 3#20
- Insulation Thickness (inches): 0.046
- Jacket Thickness (inches): 0.050
- Overall Diameter (inches): 0.442
- Net Weight (Lbs/Mft):