44 Cores 4 mm² RU P18 0.6/1KV Flame Retardant LV Power and Lighting Offshore Cable
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
44 Cores 4 mm² RU P18 0.6/1KV Flame Retardant LV Power and Lighting Offshore Cable
Allowable Ampacity for 44 Cores 4 mm² RU P18 0.6/1KV Flame Retardant LV Power and Lighting Offshore Cable: 100 Amps
Also Known As:
RU Cable, Flame Retardant Cable, Lighting Offshore Cable, LV Power Cable, Marine Cable, Marine Shipyard Cable
Construction:
• Conductor: Stranded Tinned AnneaIed Copper Wires As Per IEC 60228, CIass 2
• InsuIation: EPR As Per IEC 60092-360
• CabIing: - InsuIated Cores ShaII Be CabIed
- FIame Retardant & Non-Hygroscopic FiIIers May Be Used
- SuitabIe Tape(s) May Be AppIied On The CabIed Core
- A FiIIer May Be AppIied to Obtain A CircuIar CabIe
• Sheath: - SHF2 As Per IEC 60092-360
- Option: NEK 606 Category a,b,c,d Mud or OiI Resistant
- Outer sheath coIor: BIack
Core Identification:
No. of Cores |
Without Earth core |
With Earth core |
1C | Off-White or BIack | - |
2C | Off-White, BIack | - |
3C / 2C + E | Off-White, BIack, Red | Off-White, BIack, G/Y |
4C / 3C + E | Off-White, BIack, Red, BIue | Off-White, BIack, Red, G/Y |
5C / 4C + E | BIack No. on White InsuIation | Off-White, BIack, Red, BIue, G/Y |
6C and Over | BIack No. on White InsuIation | BIack No. on White InsuIation, G/Y |
Application Standard:
• Design Guide: NEK-606 & IEC 60092-353
• Flame Retardant: IEC 60332-1 & IEC 60332-3 Category A
• Fire Resistance: IEC 60331-21 (90min), IEC 60331-1,-2 (120min)
• Halogen Content: IEC 60754-1, 0.5% ↓
• Cold Bend / Impact: CSA C22.2 No. 2556 or IEC 60092-350 Annex.E Method 1 (-40ºC/-35ºC)
• Mud / Oil Resistant: NEK 606 (Category a,b,c,d)
• Smoke Light Transmittance: IEC 61034, 60% ↑
• Sunlight (UV) Resistant: UL 1581
Specification:
• No. of Cores: 44
• Conductor Nominal Area: 4 mm²
• Conductor Min. No. of Wires: 7 EA
• Conductor Max. overall Dia: 2.7 mm
• Thickness of Insulation: 1.0 mm
• Thickness of Sheath: 2.2 mm
• Overall Diameter Nominal: 40.8 mm
• Overall Diameter Toleranc: 1.9 ±mm
• Conductor Resistance (at 20ºC) (Max.): 4.70 Ω/km
• Insulation Resistance (at 20ºC) (Min.): 940 MΩ-km
• Test Voltage: 3500 V/5min.
• Cable Weight: 2.060 Lbs/Ft
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Reviews
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460