Application :
The 15kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs /FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant.3 Conductor, 220 Mils Tree Retardant Cross Linked Polyethylene, 133% Insulation Level, Tape Shield, Polyvinyl Chloride (PVC) Inner Jacket, Aluminum Interlocked Armour (AIA), Polyvinyl Chloride (PVC) Jacket.
Also known as:
4/0 AWG 3C 15 kV 3-Conductor Aluminum Armored Medium-Voltage Cable, 4/0 AWG 3C 15 kV Aluminum Teck Cable, 4/0 AWG 3C 3/C Aluminum MV Armored Cable, 4/0-3C 15 kV AIA Armored Cable, 4/0-3C 3-Conductor Aluminum Shielded Medium-Voltage Cable, 4/0-3C HVTECK Aluminum Cable .
Construction:
Conductor: Class B compact stranded 8000 Series aluminum per ASTM B800 and ASTM B836
Conductor Shield: Semi-conducting cross-linked copolymer; A conductor separator is used for cable size larger than or equal to 500 Kcmil
Insulation: 220 Mils Tree Retardant Cross Linked Polyethylene 133% insulation level
Insulation Shield: Strippable semi-conducting cross-linked copolymer
Copper Tape Shield: Helically wrapped 5 mil copper tape with 25% overlap
Filler: Interstices filled with non-hydroscoping/non-wicking fillers
Grounding Conductor: Class B compressed stranded bare copper ground per ASTM B3 and ASTM B8
Binder: Polypropylene tape
Inner Jacket: PVC inner jacket
Armour: Aluminum Interlocked Armour (AIA)
Overall Jacket: Red Polyvinyl Chloride (PVC) Jacket
Standards:
ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy
ASTM B836 Compact Rounded Stranded Aluminum Conductors
CSA C22.2 No. 174 Cables in Hazardous Locations
CSA C22.2 No. 2556 & No. 0.3 Wire and Cable Test Methods
CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV
CSA C68.3 Shielded & Concentric Neutral Power Cable - 5 to 46 kV
CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating
CSA HL - for Hazardous Locations rating
CSA SUN RES - for Sunlight Resistant rating
ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
ICEA T-29-520 Flame Test (210,000 BTU/Hr)
IEEE 383 Flame Test (70,000 btu)
IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
FT1 Flame Test (1,706 BTU/Hr nominal - Vertical Wire Flame Test)
AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)
Specification:
Conductor Size: 4/0 AWG
Strand: 19
Diameter Over Conductor: 0.474 inch
Diameter Over Insulation: 0.952 inch
Insulation Thickness: 220mil
Diameter Over Insulation Shield: 1.012 inch
Ground Size: 6 AWG
Inner Jacket Thickness: 110mil
Dia. Over Armour: 2.805 inch
Overall Jacket Thickness: 75
Approx. OD: 2.955 inch
Approx. Weight (lb/1000ft): 3463