350 MCM HVTECK Copper 90 mil NLEPR CB AIA 5kV 100% IL Orange PVC Jacket CSA
Application:
The 5kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs /FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant.
Also Known As:
350 MCM HVTECK 5kV Copper Cable, 1/C 90 mil NLEPR Power Cable, Copper Conductor 5kV CSA Cable, 5kV Orange PVC Jacket Cable, 350 MCM AIA Armored Medium Voltage Cable, 5kV Copper Building Wire CSA, 90 mil NLEPR Insulated Cable, 350 MCM CSA Approved 5kV Power Cable, HVTECK Copper 1 Conductor Cable, 5kV Copper Electrical Cable PVC.
Construction:
• Conductor: Class B compressed stranded bare copper per ASTM B3 and ASTM B8
• Conductor Shield: Semi-conducting cross-linked copolymer
• Insulation: 90 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 100% insulation level
• Insulation Shield: Strippable semi-conducting cross-linked copolymer
• Tape Shield: 5 mil tape shield
• Concentric Shield: Concentrically applied copper bond / shield wires. Complies with greater than the minimum requirement as per Table 44, CSA Standard C68.10 and Table 16A, Canadian Electrical Code Part 1
• Neutral Separator: Mylar tape
• Inner Jacket: PVC inner jacket
• Armour: Aluminum Interlocked Armour (AIA)
• Overall Jacket: Orange Polyvinyl Chloride (PVC) Jacket
Standards:
• ASTM B3 Soft or Annealed Copper Wire
• ASTM B8 Concentric-Lay-Stranded Copper Conductors
• CSA C22.2 No. 174 Cables in Hazardous Locations
• CSA C22.2 No. 2556 & No. 0.3 Wire and Cable Test Methods
• CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV
• CSA C68.3 Shielded & Concentric Neutral Power Cable - 5 to 46 kV
• CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating
• CSA HL - for Hazardous Locations rating
• CSA SUN RES - for Sunlight Resistant rating
• ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
• ICEA T-29-520 Flame Test (210,000 BTU/Hr)
• IEEE 383 Flame Test (70,000 btu)
• IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test (1/0 and Larger)
• FT1 Flame Test (1,706 BTU/Hr nominal - Vertical Wire Flame Test)
• AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)
Specifications:
• Size: 350 MCM
• Number of Strands: 37
• Diameter Over Conductor (inch): 0.661
• Diameter Over Insulation (inch): 0.887
• Insul. Thickness mil: 90
• Diameter Over Insulation Shield (inch): 0.947
• Concentric Neutral No. x AWG: 21x14
• Inner Jacket Thickness (mil): 80
• Diameter Over Armor (inch): 1.601
• Overall Jacket Thickness mil : 60
• Approx. OD inch : 1.721
• Copper Weight lb/1000ft: 1365
• Approx. Weight (Lbs/1000'Ft): 2145
• Min Bending Radius (In): 20.7
• DC Resistance @ 25°C Ω /1000ft: 0.031
• AC Resistance @ 90°Ω /1000ft: 0.041
• Inductive Reactance @ 60HzΩ/1000ft: 0.044
• Allowable Ampacity In Air 90°C Amp: 537
• Allowable Ampacity Directly Buried 90°C Amp: 456