350 MCM 3C Copper MV-90 Non-Shielded XLPE Insulated PVC Jacketed 2.4 kV
Application:
Per NEC, use is limited to 2400 volts maximum. For use in power system in industrial establishments and utility applications, for dry locations, in accordance with NEC.Maximum operating voltage: • 2.4 kV in accordance with UL • 5 kV 100% • 3 kV 133% per ICEA Maximum conductor operation temperatures: Wet and dry locations • Normal: 90 °C • Emergency: 130 °C • Short Circuit: 250 °C
Also Known As:
350 MCM Copper 3C MV-90, 350 MCM Non-Shielded 2.4 kV, 350 MCM Insulated cable, 350 MCM PVC Jacketed wire, 350 MCM Medium voltage cable, 350 MCM Electrical power cable, 350 MCM 2.4 kV MV-90 specifications, 350 MCM Industrial copper cable, 350 MCM 3 conductor cable.
Standards:
• UL 1072
• Medium Voltage Power Cables.
• ICEA S-96-659/NEMA WC71
• Standard for Nonshielded Cables Rated 2001-5000 Volts for Use in the Distribution of Electrical Energy.
Features:
• UL Listed as MV-90.
• Rated For CT use 1/0 AWG and up.
• Jacket is Listed Sunlight Resistant and Oil Resistant I.
• Jacket is flame retardant.
Construction:
• Conductor: Soft annealed uncoated copper compacted Class B per ASTM B496 Sizes: 8 AWG up to 1000 kcmil.
• Conductor Shield: Semi conducting cross-linked polyethylene (XLPE).
• Insulation: Thermoset crosslinked polyethylene (XLPE).
• Grounding (Optional): One or three soft annealed bare copper conductors cabled with phase conductors.
• Assembly: Conductors cabled with non-hygroscopic fillers, as required and binder tape.
• Jacket: Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound.
Specifications:
• Size: 350 MCM
• Number of Strands: 37
• Conductor Diameter (In): 0.62
• Insulation Thickness (mil): 90
• Ground Conductor Copper AWG : 2
• Jacket Thickness (mil): 110
• Approximate Outside Diameter (In): 2.08
• Approximate Net Weight Copper lb/kft: 4557
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet
Reviews
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460