350 MCM 3C Aluminum MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
350 MCM 3C Aluminum MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV
Application:
• Per NEC, use is limited to 2400 volts maximum
• For use in power system in industrial establishments and utility applications, for dry locations, in accordance with NEC.
Also Known As:
350 MCM Aluminum MV-90 Cable, 350 MCM 3C 2.4kV Non-Shielded Cable, 350 MCM EPR Insulated PVC Cable, 350 MCM Medium Voltage 3C Aluminum, 350 MCM 2.4 kV EPR Cable, 350 MCM Non-Shielded PVC Jacketed Cable, 350 MCM 3 Conductor MV-90 Cable, 350 MCM Aluminum EPR Cable 2.4 kV, 350 MCM MV-90 3C PVC Cable, 350 MCM 2.4 kV Aluminum Non-Shielded Cable
Standards:
• UL 1072
• Medium Voltage Power Cables.
• ICEA S-96-659/NEMA WC71
• Standard for Nonshielded Cables Rated 2001-5000 Volts for Use in the Distribution of Electrical Energy.
Features:
• UL Listed as MV-90.
• Rated For CT use 1/0 AWG and up.
• Jacket is listed Sunlight Resistant and Oil Resistant I.
• Jacket is flame retardant.
Construction:
• Conductor: hard drawn Aluminum-1350 compacted Class B per ASTM B400.(6 AWG Aluminum) up to 1000 kcmil.
• Conductor Shield: Semi conducting cross-linked polyethylene (XLPE).
• Insulation: Thermoset ethylene propylene rubber (EPR).
• Grounding (Optional): One or three soft annealed bare copper conductors cabled with phase conductors.
• Assembly: Conductors cabled with non-hygroscopic fillers, as required and binder tape.
• Jacket: Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound.
Specifications:
• Size: 350 MCM
• Number of Strands: 37
• Conductor Diameter (In): 0.62
• Insulation Thickness (mil): 90
• Ground Conductor Aluminum AWG : 1
• Jacket Thickness (mil): 110
• Approximate Outside Diameter (In): 2.08
• Approximate Net Weight Copper lb/kft: 2304
• Ampacity 90 °C: 345
*Data provided on this page is subject to change based on different manufacturers' variances