32A 480VAC 2-Gang Bunker Mount Reefer Outlet Assembly 22kAIC
Where are we? 4 Continents 9 Countries

Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Quick Support
Product Information
Specification
32A 480VAC 2-Gang Bunker Mount Power Distribution Unit
Ensure reliable and secure power distribution with this heavy-duty 2-Gang Bunker Mount, built for demanding industrial environments. Engineered with robust Type 4X protection, it features a 14-gauge seam-welded stainless steel enclosure with a durable powder-coated gray finish for superior corrosion resistance.
-
Voltage & Capacity:
-
60A, 480VAC (380–480VAC, 50/60Hz), 3-phase, 3-wire + ground
-
Receptacles rated at 32A 480VAC per IEC 60309-1 & -2
-
-
Enclosure & Components:
-
All stainless steel construction: enclosure, outlet frames, access cover, on/off rods, interlock mechanisms, terminal screws, springs, snap covers, and fasteners
-
Built to withstand harsh conditions with Type 4X rating
-
-
Circuit Protection:
-
UL Listed 30A trip circuit breakers with 22kAIC @ 480VAC for each outlet
-
Other trip and AIC ratings available upon request
-
-
Power Distribution Block (PDB):
-
Accepts incoming cable sizes from #6 AWG to 4/0 per phase on the line side
-
Includes (2) safety-interlocked outlets (#1700-56AN) factory-wired to the PDB
-
Also known as:
Bunker Mount assembly, 32 amp bunker mount assembly, 2 gang assembly, double gang bunker mount assembly, 480V bunker mount, Reefer Outlet, 2 gang PDB.
Product Details:
|
Environmental |
Type 4X |
| Number of Sockets | 2 |
| PDB Lugs | Aluminum |
| Contact Sleeves | Nickel Plated Brass |
| Receptacle Insert | Rynite |
| Receptacle Housing | Polyamide |
| O-rings, Gaskets, Cover Seals | Buna-N (Nitrile/NBR) |
| Weight | 53 lbs. (approx) |
Features:
• UL Listed 2-gang assembly complete with UL Listed safety-interlocked outlets each containing an integral 30A circuit breaker
• Type 4x enclosure manufactured from 14GA seam welded stainless steel (powder-coated grey)
• (2) safety-interlocked outlets 1700-56AN factory wired to power distribution block (PDB)
• UL Listed circuit breaker rated 22kAIC @ 480VAC provides short circuit overcurrent protection at each outlet
• Each oultet’s actuator rod allows user to turn on/off and reset tripped breaker
• PDB accepts incoming cable range of (2) #6AWG – 4/0 per phase line side
• Hinged access cover with clamps
Approvals:
• UL Listed modules and assembly
• UL 489 Listed / CSA certified molded case circuit breakers
Download PDF Spec Sheet
Reviews
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460
Garrie AI: Your Cable Guide