3 Cores 35 mm² JIS C 3410 0.6/1KV (FA-)TPYCSLA Shipboard Flame Retardant Power Cable
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
3 Cores 35 mm² JIS C 3410 0.6/1KV (FA-)TPYCSLA Shipboard Flame Retardant Power Cable
Allowable Ampacity for 3 Cores 35 mm² JIS C 3410 0.6/1KV (FA-)TPYCSLA Shipboard Flame Retardant Power Cable: 100 Amps
Application Standard:
- • Design guide : JIS C 3410(2010)
- • Flame retardant : IEC60332-1, : IEC 60332-3 Category A (FA-Cables Only)
- • Cold bend/impact : CSA 22.2 No. 03 (-40℃/-35℃) (Cold Type Only)
- • Max. rated conductor temperature : 90℃
Also Known As:
Protective Covered, Electric Cables, JIS C 3410 Cable, 3410 0.6/1KV Cable, Flame Retardant Cable, Power Cable
Conductor:
- • Code : D,T
- • Stranded tinned annealed copper wires as per JIS C 3410(2010)
- • A suitable tape may be applied on the conductor
Insulation:
- • Code : P
- • EPR as per JIS C 3410(2010)
- • Insulated conductors shall be cabled
Cabling:
- • Flame retardant & non-hygroscopic fillers may be used
- • Suitable tape(s) may be applied on the cabled core
Commonshield:
- • Code : SLA
- • Screened by AL/PS tape with tinned copper drain wire
- • A suitable tape may be applied on the common shield
Sheath:
- • Code : Y
- • PVC as per JIS C3410(2010)
Armour:
- • Code : C
- • Braid of galvanized steel wire(C)
- • Coverage density : Min. 90%
Paint:
- • The white paint shall be painted uniformly on the steel wire braid
- • In case of PVC protective covering cable, paint isdispensable
Protective Covering:
- • Code : Code : Y
- • PVC as per JIS C3410(2010)
- • Protective covering color : Black
- • Any other color may be applicable when purchaser required
Core identification :
No. of cores | Insulation Color |
2C | Black,White |
3C | Black, White,Red |
Specification:
- • No. of Cores : 3
- • Conductor Nominal Area : 35 mm²
- • Conductor Strand : 7 / 2.52 No./mm
- • Conductor Dia. : 7.56 mm
- • Nominal Dia. Over Sheath : 26.3 mm
- • (FA-)TPYCSLA Nominal Dia. : 27.6 mm
- • (FA-)TPYCSLA Tolerance : 1.1±mm
- • Conductor Resistance (at 20°C) (Max): 0.529 Ω/km
- • Insulation Resistance (at 20°C) (Min): 450 ㏁ - km
- • Cable Weight : 1.235 Lbs
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Reviews
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460