268-40-3516 14 AWG 16P Stranded Bare Copper Shield XLPE TC Drain Al Tape PVC SP-OS Okonite Marine Cable

Where are we? 4 Continents 8 Countries


Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
268-40-3516 14 AWG 16P Stranded Bare Copper Shield XLPE TC Drain Al Tape PVC SP-OS Okonite Marine Cable
Allowable Ampacity for 268-40-3516 14 AWG 16P Stranded Bare Copper Shield XLPE TC Drain Al Tape PVC SP-OS Okonite Marine Cable:100 Amps
About:
The 268-40-3516 14 AWG 16P Stranded Bare Copper Shield XLPE TC Drain Al Tape PVC SP-OS Okonite Marine Cable. It features stranded bare copper conductors, XLPE (cross-linked polyethylene) insulation, a tinned copper (TC) drain wire, an aluminum (Al) tape shield, and a PVC (polyvinyl chloride) outer jacket. This marine cable is designed to deliver reliable performance in harsh marine environments, providing excellent resistance to moisture, chemicals, and physical wear.
Also Known As:
• Marine Shielded Control Cable
• Marine Instrumentation Cable
• XLPE Insulated Marine Cable
• Shielded Marine Cable
Application:
X-Olene Okoseal 600 volt shielded instrumentation cables are designed for use in rugged plant environments, such as Offshore Rig Projects, on Class 1 Remote-Control Signaling circuits or where a 600V instrumentation or control cable is desired.They are designed for use indoors or outdoors; wet or dry locations; in cable trays; in raceways; supported by a messenger wire; and for direct burial. Can be installed as Type TC/ITC in Class I, Division 2; Class II, Division 2; Class III, Division 1; and Zone 2 hazardous locations in accordance with NEC Articles 501.10, 502.10, 503.10, and 505.15. TC-ER (Tray Cable - Exposed Run) eliminates the need for conduit when installed in accordance with NEC Article 336.10(7). These cables are also UL labeled Okomarine and are listed for marine applications.
Standards:
• IEEE 45 - Recommended Practice for Electrical Installations on Shipboard
• UL 1309 - Standard for Marine Shipboard Cable
• ABS (American Bureau of Shipping) approved
• USCG (United States Coast Guard) approved
• Lloyd's Register of Shipping approved
• DNV-GL (Det Norske Veritas Germanischer Lloyd) approved
• IEC 60092-353 - Electrical installations in ships – Part 353: Power cables for rated voltages 1 kV and 3 kV
• NEK 606 - Cables for Offshore Installations
Construction:
• Insulated Conductors: Bare soft annealed copper, Class B stranded per ASTM B8.
• Insulation: X-Olene (XLPE), 30 mils ® nominal thickness, 90°C temperature
rating. Meets or exceeds requirements of UL 1277, UL 2250, UL 1309 Type
X90 and IEEE 1580 Type X crosslinked polyethylene insulation.
• Color Coding: Pigmented black and white in pairs, black, red and white in
triads; white conductor numericallyprinted for group identification.
• Unit Shield: Aluminum/Polyester tape overlapped to provide 100% coverage, and
a tinned-copper Class M drain wire, two sizes smaller than conductor. All multi-unit
shields are isolated from each other.
• Multiple Unit Assembly: Pairs/Triads assembled with a left-hand lay.
• Multiple Unit Cable Shield: Aluminum/Polyester tape overlapped to provide 100% coverage, and a class M strand tinned copper drain wire, same size as the conductor.
• Jacket: Black Okoseal jacket. Complies with UL 1277, UL 2250, UL 1309 & IEEE 1580 Type T, thermoplastic polyvinyl chloride jacket.
• UL Listed as Type TC-ER cable with a sunlight resistant jacket and for direct
burial.
• UL Listed as Type ITC-ER cable with a sunlight resistant jacket and for direct
burial.
• UL Listed as Type OKO-MARINE signal cable to the requirements of UL 1309. Also,
UL certified as meeting the requirements of IEEE 1580 — Marine Cable
Features:
• For cable tray use and direct burial.
• Sunlight resistant.
• Insulated conductors are UL rated 90°C continuous rating in wet or dry locations.
• Flame Retardant - passes the vertical tray flame test requirements of IEEE 383-1974
& 1202-2010 and UL 1277.
• X-Olene Okoseal Type TC-ER/ITC-ER cables are quality control inspected to meet
or exceed applicable industry standards.
• Resistant to moisture and most chemical atmospheres.
• Thermal stability at elevated temperatures.
• CSA C22.2 No. 239 & 230 Type CIC-TC (Type CIC-TC-ER for 14 AWG and
larger).
• CSA C22.2 No. 245 Type Marine Shipboard.
• Passes -35°C cold bend test
Specifications:
• Number of Pairs: 16
• Jacket Thickness-mils: 80
• Nominal O.D. - Inches: 1.32
• Cross-Sectional Area (sq in): 1.37
• Approx. Net Weight: 1053
• Part Number: 268-40-3516
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet
Reviews