Product Information
Specification
267-92-4904 18 AWG 4P Stranded Tinned Copper Shield XLPE Drain Al Tape Orange Okoseal Okobus Fieldbus Cable
Allowable Ampacity for 267-92-4904 18 AWG 4P Stranded Tinned Copper Shield XLPE Drain Al Tape Orange Okoseal Okobus Fieldbus Cable:100 Amps
About:
The 267-92-4904 Okobus Fieldbus Cable is a specialized cable designed for use in industrial communication networks. It features an 18 AWG (American Wire Gauge) single pair of stranded tinned copper conductors, which provides excellent conductivity and flexibility. The cable is insulated with XLPE (cross-linked polyethylene) for superior heat resistance and dielectric properties. It includes a drain wire and aluminum tape shielding to minimize electromagnetic interference (EMI). The outer jacket is made of orange Okoseal (PVC), offering additional protection and visibility.
Also Known As:
• Fieldbus Cable
• Profibus Cable (if used in Profibus networks)
• Industrial Ethernet Cable (in specific configurations)
• Control and Data Communication Cable
Application:
• Okonite® OKOBUS® cables are designed for use in rugged plant environments utilizing networked discrete or process automation and control. ITC-ER (Instrument Tray Cable - Exposed Run) eliminated the need for conduit when installed in accordance with NEC Article727.4(6). Fully complies with Fieldcom Group FF-844.
• The isolated individual shields over each pair, when properly grounded, prevent crosstalk or capacitive coupling between adjacent pairs which occurs with ac signals, particularly the pulse type.
• The overall shield eliminates most of the static interference from the electrical field
radiated by power cables and other electrical equipment
Standards:
• IEC 61158: Fieldbus for use in industrial control systems
• UL 1581: Reference standard for electrical wires, cables, and flexible cords
• NFPA 79: Electrical Standard for Industrial Machinery
• RoHS Compliant: Restriction of Hazardous Substances Directive
• ANSI/TIA-568: Commercial Building Telecommunications Cabling Standard
• IEEE 802.3: Standard for Ethernet
Construction:
• Conductors: #18 AWG and #16 AWG tinned copper, Class B, stranded per ASTM B-8.
• Insulation: X-Olene (cross linked polyethylene) per UL 13 and 2250, 32 mils nominal thickness, 90°C temperature rating.
• Conductor Identification: Pigmented orange and blue in pairs, orange conductor numerically printed for group identification.
• Pair Shield: Aluminum/Polyester tape overlapped to provide 100% coverage, and a Class B tinned copper drain wire, two sizes smaller than the conductor. All multi-pair shields are isolated from each other.
• Multiple Pair Assembly: Twisted pairs assembled with a left-hand lay. Cable fillers
included where required to provide a round cable.
• Multiple Pair Cable Shield: Aluminum/Polyester tape overlapped to provide 100% coverage, and a Class B strand tinned copper drain wire, same size as conductor.
• Jacket: Orange, flame-retardant, Okoseal per UL 13 and 2250. A rip cord is laid longitudinally under the jacket to facilitate removal.
• Classifications: UL Listed as PLTC-Power Limited Tray Cable and as ITC-ER - Instrument Tray Cable/Exposed Run for use in accordance with Article 727 and Article 725 of the National Electrical Code.
• Cables comply with FF-844, UL 2250 and UL 13 for Fieldbus circuits and CL2 and CL3.
Features:
• FF-844 Foundation Fieldbus Type A.
• Passes the UL 13 and IEEE 383 vertical tray flame tests.
• Single pair passes IEEE 1202 vertical tray flame test.
• Sunlight & oil resistant.
• UL listed for direct burial.
• Individual pairs are completely isolated.
• 100% shield coverage for reduced electromagnetic noise pick-up.
• Excellent external noise rejection.
• Excellent weathering characteristics.
• OSHA Acceptable.
• Flexible, easy to handle and terminate.
• -30C to 90C.
• Foundation Fieldbus Registered
Specifications:
• Number of Pairs: 4
• Jacket Thickness-mils: 60
• Nominal O.D. - Inches: 0.70
• Cross-Sectional Area (sq in): 0.38
• Approx. Net Weight: 225
• Part Number: 267-92-4904
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Download PDF Spec Sheet
Reviews
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460