Application:
The 25kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs /FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant.
Also Known As:
250 MCM 3C HVTECK Copper 3/C 320 mil cable, NLEPR TS AIA 25kV cable, 320 mil copper cable 25kV, CSA 25kV cable, 3 conductor 25kV cable, 250 MCM 3C HVTECK NLEPR TS AIA cable, 133% insulation 25kV cable, 320 mil PVC jacketed wire, 250 MCM 3C HVTECK CSA cable 25kV, 3/C 25kV copper wire.
Construction:
• Conductor: Class B compressed stranded bare copper per ASTM B3 and ASTM B8
• Conductor Shield: Semi-conducting cross-linked copolymer
• Insulation: 320 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% insulation level
• Insulation Shield: Strippable semi-conducting cross-linked copolymer
• Copper Tape Shield: Helically wrapped 5 mil copper tape with 25% overlap
• Filler: Interstices filled with non-hydroscoping/non-wicking fillers
• Grounding Conductor: Class B compressed stranded bare copper ground per ASTM B3 and ASTM B8
• Binder: Polypropylene tape
• Inner Jacket: PVC inner jacket
• Armour: Aluminum Interlocked Armour (AIA)
• Overall Jacket: Black Polyvinyl Chloride (PVC) Jacket
Standards:
• ASTM B3 Soft or Annealed Copper Wire
• ASTM B8 Concentric-Lay-Stranded Copper Conductors
• CSA C22.2 No. 174 Cables in Hazardous Locations
• CSA C22.2 No. 2556 & No. 0.3 Wire and Cable Test Methods
• CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV
• CSA C68.3 Shielded & Concentric Neutral Power Cable - 5 to 46 kV
• CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating
• CSA HL - for Hazardous Locations rating
• CSA SUN RES - for Sunlight Resistant rating
• ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
• ICEA T-29-520 Flame Test (210,000 BTU/Hr)
• IEEE 383 Flame Test (70,000 btu)
• IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
• FT1 Flame Test (1,706 BTU/Hr nominal - Vertical Wire Flame Test)
• AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)
Specifications:
• Size: 250 MCM
• Number of conductor: 3
• Number of Strands: 37
• Diameter Over Conductor (inch): 0.558
• Diameter Over Insulation (inch): 1.244
• Insul. Thickness mil: 320
• Diameter Over Insulation Shield (inch): 1.304
• Ground Size AWG: 4
• Inner Jacket Thickness (mil): 125
• Diameter Over Armor (inch): 3.466
• Overall Jacket Thickness mil : 85
• Approx. OD inch : 3.636
• Copper Weight lb/1000ft: 2543
• Approx. Weight (Lbs/1000'Ft): 6769
• Min Bending Radius (In): 25.5
• DC Resistance @ 25°C Ω /1000ft: 0.043
• AC Resistance @ 90°Ω /1000ft: 0.056
• Inductive Reactance @ 60HzΩ/1000ft: 0.042
• Allowable Ampacity In Air 90°C Amp: 384
• Allowable Ampacity Directly Buried 90°C Amp: 408