*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
Insulation
X-Olene® is Okonite’s trade name for its cross-linked polyethylene, with high dielectric strength insulation.
Jacket
The Okoseal (PVC) jacket supplied with this cable is mechanically rugged and has excellent resistance to acids and most chemicals and is rated for low temperature installations.
Applications
Okonite X-Olene Okoseal tray cable is permitted for use on power, lighting, control, and signal circuits; indoors or outdoors; in cable trays, raceways, direct burial in the ground, or where supported in outdoor locations by a messenger wire; for Class 1 circuits as permitted in Article 725 of the NEC; and in cable trays in Class I, Division 2 hazardous locations in industrial establishments where the conditions of maintenance and supervision assure that only qualified persons will service the installation. Cables marked TC-ER may also be used between a cable tray and the utilization equipment or device, when installed in accordance with NEC 336.10(7).
Specifications
Conductors: Uncoated soft copper per ASTM B-3. Sizes smaller than #8 are compress stranded per ASTM B-8. Sizes #8 and larger are compact stranded per ASTM B-496.
Insulation: X-Olene insulation per UL 1581, listed as XHHW-2.
Color Coding: Base colors and tracers as shown on reverse of Data Sheet and, for sizes #8 AWG and larger, black conductors with surface printing of numbers and colors per ICEA S-73-532 NEMA/WC57 Method 3.
Grounding Conductor(s): Where indicated, bare stranded copper per ASTM B-8, or compact round per ASTM B-496, Class B & NEC Table 250.122.
Assembly: Conductors cabled in accordance with UL 1277 and 1309 using fillers, as necessary, with a cable tape overall.
Overall Jacket: Complies with UL 1277. The Okoseal compound meets or exceeds the requirements of UL 1581.
Cable passes the Vertical Tray Flame
Test requirements of UL 1277 for Type
TC Power and Control Tray Cable.
UL Listed as Type TC or TC-ER cable with a sunlight resistant jacket and for direct burial.
Product Features
Insulated conductors are UL Listed Type XHH / XHHW-2.
90°C continuous rating in wet or dry locations.
130°C emergency overload rating.
250°C short circuit rating.
X-Olene Okoseal Type TC or TC-ER cables are quality control inspected to meet or exceed applicable industry standards.
Resistant to moisture and most chemical atmospheres.
Thermal stability at elevated temperatures.
Easy to install and terminate.
Mechanically rugged.
High dielectric strength.
Small diameter, lightweight.
Minimum installation temperature of -40°C.
Applicable Standards
- UL listed for cable tray use, direct burial, in ducts, and sunlight resistant.
- Vertical Tray Flame Tests: IEEE 383-1974, Sizes 4/0 AWG and larger meet FT4/IEEE 1202.
- CSA C22.2 No. 239 Type CIC for sizes 4/0 AWG and smaller.
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.