2 AWG 3C Type MV -105 Copper 5/8kV NLEPR Insulation 133/100% IL GSIA Yellow PVC Jacket

2 AWG 3C Type MV -105 Copper 5/8kV NLEPR Insulation 133/100% IL GSIA Yellow PVC Jacket
Roll over image to Zoom
2 AWG 3C Type MV -105 Copper 5/8kV NLEPR Insulation 133/100% IL GSIA Yellow PVC Jacket
SKU: NNC10241
type-mv-105-three-conductor-copper-5-8kv-nlepr-insulation-133-100-il-gsia-yellow-pvc-jacket
Min Length: 1 FT
Max Length: 10000 FT
Price:
Regular price
$0.00 /FT
Sale price
$0.00 /FT
Shipping Cost Calculated at Checkout. Standard Lead Time is 1 to 6 Business Days.
Free Shipping: On orders above $1000
Quantity must be 1 or more

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Where are we? 4 Continents 9 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Product Information
Specification

2 AWG 3C Type MV -105 Copper 5/8kV NLEPR Insulation 133/100% IL GSIA Yellow PVC Jacket

Application:

The 5KV cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated at
-35°C for cold bend when UL listed. Rated at -40°C for cold bend and cold impact and marked with "LTGG" when CSA listed or dual UL/CSA listed. For uses in Class I and II, Division 2 hazardous locations per NEC Article 501 and 502.Rated for 1000 lbs./FT maximum sidewall pressure.

Also Known As:

2 AWG 3C MV-105 cable, Three conductor copper cable, 5/8kV NLEPR insulation, 133/100% IL cable, GSIA yellow PVC jacket, 2 AWG 3C MV-105 power cable, NLEPR insulated wire, High voltage copper cable, Low smoke PVC jacket, 2 AWG 3C Industrial power cable MV-105.

Standards:

• ASTM B3 Soft or Annealed Copper Wire
• ASTM B8 Concentric-Lay-Stranded Copper Conductors
• ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
• UL 1072 Medium-Voltage Power Cables
• UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test
• ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
• ICEA S-97-682 Standard for Shielded Utility Cable Rated for 5 - 46kV
• AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)
• Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661

Construction:

• Conductor: Class B compressed stranded bare copper per ASTM B3 and ASTM B8 (Tinned Copper per ASTM B33 optional)
• Conductor Shield: 
Semi-conducting cross-linked copolymer
• Insulation: 
115 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level,
• Insulation Shield: 
Strippable semi-conducting cross-linked copolymer
• Copper Tape Shield: 
Helically wrapped 5 mil copper tape with 25% overlap
• Grounding Conductor: 
Class B compressed stranded bare copper ground per ASTM B3 and ASTM B8 (Tinned Copper per ASTM B33 optional)
• Filler: 
Wax paper filler
• Binder: 
Polypropylene tape
• Armor: 
Galvanized Steel Interlocked Armor (GSIA)
• Overall Jacket: 
Polyvinyl Chloride (PVC) 

Specifications:

• Size: 2 AWG
• Number of Conductor: 3 + 1G
• Number of Strands: 7
• Diameter Over Conductor (inch):  0.282
• Diameter Over Insulation (inch):  0.550
• Diameter Over Insulation Shield (inch):  0.610
• Ground No. x AWG: 1x6
• Diameter Over Armor (inch):  1.682
• Jacket Thickness (mil): 60
• Approx. OD (In):  1.802
• Copper Weight lb/1000ft: 737
• Approx. Weight (Lbs/1000'Ft): 2166
• Min Bending Radius (In):  12.6
• DC Resistance @ 25°C Ω /1000ft:  0.162
• AC Resistance @ 90°Ω /1000ft:  0.204
• Inductive Reactance @ 60HzΩ/1000ft:  0.040
• Allowable Ampacity In Duct 90/105°C Amp :  135/145
• Allowable Ampacity In Air 90/105°C Amp: 140/154


*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color