18 Fiber 33 Series Tight Buffered Plenum Distribution 900µm Indoor Optic Cable

Where are we? 4 Continents 9 Countries


Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Quick Support
18 Fiber 33 Series Tight Buffered Plenum Distribution 900µm Indoor Optic Cable
Allowable Ampacity for 18 Fiber 33 Series Tight Buffered Plenum Distribution 900µm Indoor Optic Cable: 100 Amps
Applications:
Outdoors in Duct, Indoors in the Plenum Space, Tray Installations
Also Known as:
Indoor Cable, Fiber Optic Cable, 33-Series Cable, Tight Buffered Cable, Indoor Fiber Optic Cable, Fiber Cable
Scope:
This document establishes the specification requirements for a distribution indoor all dielectric fiber optic cable. This cable construction consists of a distribution tight-buffer design with a plenum rated jacket.
Cable Construction Details:
•Tight Buffer Color Code:
As per TIA/EIA-598 standard or per customer requirement
•Sub Unit Construction:
Aramid yarns are pulled in with tight buffered fibers under a sub-unit jacket.
•Dielectric Central Strength Member:
Epoxy Glass Rod (up-coated as required per construction)
•Cable Core:
Sub-units and fillers are stranded around the CSM, using reverse oscillation
A non-wicking and non-hygroscopic tape is applied longitudinally over the cabled core with a 25% nominal overlap.
Binder yarns are applied over the core tape.
•Overall Sheath:
UV Resistant Remguard Plenum Rated Polymer
Applicable Documents:
-TIA/EIA FOTP Standards 455
-Color Coding of Fiber Optic Cables TIA/EIA-598
-UL 910
-GR-409-CORE
-Compliant with ANSI/TIA-568-C.3 standard
Specification:
Number of Fiber: 18
Cable O.D: 0.546 in
Dimension: 900µm, Nominal
Temperature Rating: Operation : -20°C to +85°C Installation : 0°C to +75°C Storage : -40°C to +85°C
Weight: 104 lbs/1000ft
Part Number: 33-018-XXX-RXSFNP