18/1 Shielded Triads Overall Shield (STOS) XLP/PVC TC-ER
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
18/1 Shielded Triads Overall Shield (STOS) XLP/PVC TC-ER
Applications:
Tray instrumentation control electrical cables are designed to be used in cable trays and raceways. They are predominantly used in control circuits and instrumentation applications and when supported by a messenger wire. The electrical cable can also be used for power, lighting, control, signal, and fire alarm circuits. The temperature range of the instrumentation cable is -30°C to 90°C. The cable is resistant to oil and sunlight. The voltage rating is 600 volts. It is approved for direct burial.
Also Known As:
18/1 Cable Tray, 18/1 Cable Tray Types, 18/1 Electrical Cable Tray, 18/1 Pvc Cable Tray, 18/1 wire cable tray, 18/1 cable tray wire, 18/1 STOS cable, 18/1 XLP Cable, 18/1 PVC Cable, 18/1 Shielded Tray Cable, 18/1 Triad Cables, 18/1 Tray Instrument Cable, 18/1 Shielded Instrument Cable, 18/1 Type TC-ER Cable, Power and Control Tray Cable Type TC, 18/1 Type TC cable.
Standards:
- • UL Standard 1277 Type TC-ER
- • NEC Article 336
- • UL 1685 Flame Test
- • IEEE 383 Flame Test
- • ICEA S-73-532
- • ICEA S-95-658 (WC70)
- • EPA 40 CFR
A stranded bare copper conductor with excellent conductivity per ASTM B-8 and B-3. Conductors are highly flexible.
Insulation:
XLPE cross-linked polyethylene insulation is resistant to moisture, flame, heat, and mechanical impact. It is flame-retardant and oil-resistant. The insulation has good dielectric strength and minimum resistance. It is very flexible so that the cable can be folded with ease.
Jacket:
PVC is a black durable jacket resistant to moistures, flames, abrasion, chemicals, oils, sunlight, and acids. The jacket is color-coded in black and white.
Shield:
An aluminum or polyester foil shield is designed for extra protection from high-power voltages and electrical interference.
Specification:
- • Gauge :18
- • No. Conductors: 1
- • Stranding: 7/0.0152
- • Insulation Wall, Nom OD Inches: 0.030
- • O.D. Inches: 0.336
- • New Weight lb/1000FT: 50 Lbs
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Reviews
Call Us: 1-516-482-6313 Text Us: 1-516-703-3460