160-23-8152 1250 MCM 1C Aluminum Unshielded EPR Concentric 1/6 Neutral

Items in Cart ()

View cart

160-23-8152 1250 MCM 1C Aluminum Unshielded EPR Concentric 1/6 Neutral Okolene 580 46KV Okoguard URO-J Cable

160-23-8152 1250 MCM 1C Aluminum Unshielded EPR Concentric 1/6 Neutral Okolene 580 46KV Okoguard URO-J Cable
Roll over image to Zoom

160-23-8152 1250 MCM 1C Aluminum Unshielded EPR Concentric 1/6 Neutral Okolene 580 46KV Okoguard URO-J Cable

SKU: 160-23-8152

Select a Gauge

160-23-8152 1250 MCM 1C Aluminum Unshielded EPR Concentric 1/6 Neutral Okolene 580 46KV Okoguard URO-J Cable
Price:
Regular price
$0.00 /Qty
Sale price
$0.00 /Qty
Shipping Cost Calculated at Checkout. Standard Lead Time is 1 to 6 Business Days.
Free Shipping: On orders above $1000
Quantity must be 1 or more

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Where are we? 4 Continents 8 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Chat

Live Chat: Bottom Right Corner!

Email Us

info@nassaunationalcable.com

Product Information

Specification

160-23-8152 1250 MCM 1C Aluminum Unshielded EPR Concentric 1/6 Neutral Okolene 580 46KV Okoguard URO-J Cable

Allowable Ampacity for 160-23-8152 1250 MCM 1C Aluminum Unshielded EPR Concentric 1/6 Neutral Okolene 580 46KV Okoguard URO-J Cable:100 Amps

About:

This cable is designed for power distribution, typically in utility networks. It features a high-voltage capacity, making it suitable for applications requiring a voltage rating up to 46KV. The use of aluminum conductors makes it a cost-effective option for bulk power transfer.

Also Known As:

It may also be referred to as a high-voltage aluminum cable or EPR (Ethylene Propylene Rubber) insulated cable. The specific naming can vary based on the manufacturer or the distributor.

Application:

 Power transmission lines
 Primary and secondary distribution
 Overhead and underground installations where high voltage is required
 Industrial settings for connecting substations to grids or large machinery

Standards:

This cable typically meets standards set by the IEEE for high-voltage cables. These may include specific requirements for insulation, conductor size, and resistance to environmental factors. Standards such as IEEE 1202 for flame testing and IEEE 383 for a thermal evaluation may also be relevant.

Construction:

• Conductor: Uncoated copper sizes 4/0 AWG through 1000 kcmil are compact round strand per ASTM B496. Uncoated copper sizes larger than 1000 kcmil are compressed Class B strand per ASTM B3 and ASTM B8. Aluminum per ASTM B609, compressed Class B strand per ASTM B231.
• Conductor Screen: Extruded semiconducting ethylene-propylene rubber meets or exceeds the requirements of ICEA S-94-649, AEIC CS8, and CSA C68.5.

 Insulation: Extruded Okoguard meets or ® exceeds the requirements of ICEA S-94-649, AEIC CS8, and CSA C68.5.
• Insulation Screen:
 Extruded semiconducting EPR insulation screen. Meets or exceeds electrical and physical requirements of ICEA S-94-649, AEIC CS8, and CSA C68.5.
• Concentric Conductor: 
Bare copper concentric neutral wires helically applied.
 Jacket: Black OKOLENE LLDPE with red ® extruded stripes. Meets or exceeds the requirements of ICEA S-94-649, AEIC CS8, and CSA C68.5 for polyethylene jackets.

Features:

 Triple tandem extruded, all EPR system.
 Okoguard cables meet or exceed ICEA standards.
 Improved temperature rating. Okoguard insulation system has been tested and qualified for operation at 105°C continuous and 140°C emergency operating temperature.
 250°C short circuit rating.
 Excellent corona resistance.
 Low dielectric constant and power factor.
 Screens are clean stripping.
 Exceptional resistance to "treeing".
 Moisture resistant.
 Excellent resistance to most chemicals.
 CSA C68.5 listed, LTGG (-40°C), SR.

Specifications:

• Conductor Size AWG kcmil: 1250(91x)
• Neutral Size: 1/6

 Neutral Wires Num X AWG:
20x12
• Nominal Dia. Over Insulation (in): 2.49 
• Nominal Dia. Over Screen (in): 2.63
• Jacket Thickness (miles): 80
• Nominal O.D (in): 2.96
• Approx. Net Weight: 4513
• 90° C Ampacity Duct: 612 

• 105° C Ampacity Duct: 659

• Part Number: 160-23-8152


*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color

Download PDF Spec Sheet

Reviews

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Get in Touch
Live Chat Get replies right away!
Email info@nassaunationalcable.com

Call Us: 1-516-482-6313    Text Us: 1-516-703-3460