16 AWG 3C Bare Copper Unshielded PVC Sumflex® RVMV-K 0.6/1kV Eca CPR Galvanized Steel Armored Cable
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
16 AWG 3C Bare Copper Unshielded PVC Sumflex® RVMV-K 0.6/1kV Eca CPR Galvanized Steel Armored Cable
Allowable Ampacity for 16 AWG 3C Bare Copper Unshielded PVC Sumflex® RVMV-K 0.6/1kV Eca CPR Galvanized Steel Armored Cable: 100 Amps
Application:
The RVMV-K CPR cables comply with the criteria for the classification of construction products according to CPR Regulation 305/2011 and the EN 50575
standard, being those indicated in installations of low voltage distribution networks, connections and lighting in all types of Industrial plants.
Suitable for the following installations:
• ITC-BT 07 Underground networks for low voltage distribution
• ITC-BT 09 Underground power networks for outdoor lighting installations
• ITC-BT 11 Electrical power distribution networks. underground connections
• ITC-BT 20 Interior or reception installations
• ITC-BT 30 Installations in premises with special characteristics
Also Known as:
Sumflex Cable, CPR Cable, RVMV-K Cable, SumCab Cable, Flexible Cable, RVMV-K CPR Cable
Design:
• Flexible electrolytic copper conductor (Class 5) according to UNE-EN 60228, EN 60228 and IEC 60228 Insulation
• Cross-linked polyethylene (XLPE) type DIX 3 according to UNE 21123, HD 603 S1 and IEC 60502-1 Conductor
• identification according to UNE 21089 and HD 308 S2
• Polyvinyl chloride seat
• Galvanized steel wire crown reinforcement
• Polyvinyl chloride type DMV-18 according to UNE 21123, UNE-HD 603-1 and IEC 60502
• Black color
Technical Data:
Rated voltage 0.6/1 kV Test
voltage 3,500 V AC
Maximum temperature 90 °C (250 °C for 5 seconds in the event of a short circuit)
Minimum radius of curvature 10 x External diameter in fixed installation Service
temperature -25 °C to +90 °C
Specification:
AWG Size: 16
Number of Conductor: 3
Conductor: Bare Copper
Conductor x Section: 3G 1.50 mm²
Resistance at 20°C: 13.30 ohm/km
Diameter Under Armor: 8.3 mm
Outside Diameter Approx: 12.9 mm
Rated Voltage: 0.6/1kV
Weight: 204.95 lbs/MFT
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color